UTVÄRDERING AV EKG– STÖRNINGAR UNDER ARBETSPROV MED OCH UTAN SPORT–BH VID ANVÄNDNING AV ENGÅNGSELEKTRODER
Malmö University, Faculty of Health and Society (HS).
2020 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Abstrakt: Arbetsprov utförs i syfte att undersöka hjärtats funktion under belastning. Under underökningen registreras elektrokardiografi (EKG) på bar överkropp med hjälp av EKG-elektroder. För kvinnliga patienter kan cyklingen med bar överkropp utan stöd i form av BH upplevas som obehagligt. Idag används det olika sorters elektroder vid olika kliniker. En tidigare studie visade att sugelektroder som användes vid koppling av EKG under arbetsprov då kvinnliga frivilliga deltagare hade mjuk sport–BH inte gav några signifikanta EKG– störningar jämfört med om deltagarna genomförde arbetsprov utan sport-BH. Syftet med denna studie var därför att undersöka om en mjuk sport-BH orsakar störningar på EKG med engångselektroder jämfört med arbetsprov utfört utan sport-BH. Vid registrering av EKG kan olika störningar uppstå. Dessa störningar kan vara i form av muskelstörningar, bero på elektrodglapp eller växelströmstörningar. Utvärderingen av EKG-störningarna baserades på analys av 20 olika EKG–remsor från 10 frivilliga kvinnliga deltagare. Analysen utfördes med hjälp av sammanställda värden för QRS– och QT-durationerna samt amplituderna för R- och T–vågen. Samtliga EKG-registreringar bedömdes visuellt, avseende störningsnivå, av en läkare. Därefter genomfördes ett statistiskt tvåsidigt test med hjälp av Wilcoxons teckenrangtest. Resultatet visade att amplituderna inte påverkades vid användning av sport–BH, Resultatet visade att amplituderna inte påverkades vid bärandet av sport–BH, dock så avvek QT–tiden från resterande värden. Artefakter i form av svaga baslinjestörningar detekterades vid maxbelastning vid användning av sport–BH men även utan. Utifrån den statistiska analysen av den visuella bedömningen av störningsnivåerna drogs slutsatsen att inga signifikanta skillnader på EKG–registreringarna förekom mellan undersökningarna.

Abstract [en]

Abstract: Exercise tests are performed in order to examine the heart function under exertion. Electrocardiography (ECG) is recorded using ECG electrodes attached to the chest. For female patients, cycling bare-chested without support in the form of a bra may be perceived as uncomfortable. Today, different types of electrodes are used in different clinics. A previous study showed that suction cup electrodes used to register ECG during exercise tests when female participants had soft sports bra did not give significant ECG interference compared with performing exercise tests without it. The aim of the present study was to investigate whether a soft sports bra causes disruptions in the ECG with disposable electrodes compared to exercise tests performed without a sports bra. Different errors can occur during the registration of an ECG such as somatic tremors artifact, due to baseline sway or electrical interference. The evaluation of the ECG disorders was based on analysis of 20 different ECG from 10 female participants. The analysis was made in compiled values for the QRS and QT durations as well as the amplitudes for the R and T waves. All ECG recordings were visually assessed by a physician in regard of noise quality. Subsequently, a statistical two-sided test was performed using Wilcoxon's character rank test. The results showed that the amplitudes were not affected by wearing of sports bra, however the QT– time differed from the remaining values. Interference in form of minor baseline disorders were seen at maximum workload in in both tests. Based on the statistical analysis by the visual analysis of the ECG noise levels, it was concluded that no significant differences on the ECG registrations were found between the tests.

Place, publisher, year, edition, pages
Malmö universitet/Hälsa och samhälle , 2020.
Keywords [sv]
arbetsprov, artefakter, engångselektroder, elektrokardiografi, ergometercykel, sport-BH, störningar
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-26993Local ID: 32655OAI: oai:DiVA.org:mau-26993DiVA, id: diva2:1488598
Educational program
HS Biomedicinsk laboratorievetenskap
Available from: 2020-11-03 Created: 2020-11-03Bibliographically approved

Open Access in DiVA

fulltext(967 kB)3383 downloads
File information
File name FULLTEXT01.pdfFile size 967 kBChecksum SHA-512
47a1b1b369767fb20e1343d9bf14b38f21612ff2ea9ae064e39b1223aac79466128e3760771555ae49ff13550bd97c15f6ff4649fe4f58b86d5c62a5ee55c341
Type fulltextMimetype application/pdf

By organisation
Faculty of Health and Society (HS)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 3388 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1315 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf