Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Jämförelse av diastoliska parametrar i liggande respektive sittande ställning
Malmö högskola, Faculty of Health and Society (HS).
2010 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

JÄMFÖRELSE AV DIASTOLISKA PARAMETRAR I LIGGANDE RESPEKTIVE SITTANDE STÄLLNING ZAHRAA ALSAFI Alsafi Z. Jämförelse av diastoliska parametrar i liggande respektive sittande ställning. Examensarbete i i biomedicinsk laboratorievetenskap 15 högskolepoäng. Malmö högskola: Hälsa och samhälle, Utbildningsområde Biomedicinsk laboratorievetenskap, 2010. Ändringar av kroppsställning medför ändringar i hjärtats diastoliska funktion. Studier har visat med hjälp av icke-invasiva metoder utförda med ekokardiografi, att de diastoliska parametrarna är större vid liggande i jämförelse med exempelvis stående ställning. Denna ändring uppkommer på grund av ändringar i bland annat preload och fyllnadstryck vid ändringar i kroppsställning. Syftet med denna studie var att mäta hjärtats diastoliska parametrar vid liggande samt sittande ställning för jämförelse. Pulsad dopplerteknik och vävnadsdoppler teknik användes för att registrera de diastoliska parametrarna hos 30 konsekutiva patienter på Kardiologiska kliniken SUS Malmö. Med pulsad dopplerteknik registrerades E- och A-vågshastigheter vid mitralisklaffarnas öppning. En E/A-kvot beräknades för samtliga patienter. Vävnadsdoppler användes för att registrera É-vågshastigheten septalt samt lateralt och ett É-medelvärde räknades utifrån dessa två mätningar. Med detta värde samt den tidigare mätta E-vågshastigheten beräknades en E/É-kvot för samtliga patienter. Med hjälp av t-test för parvisa observationer gjordes en jämförelse av E/A-kvoten mellan liggande och sittande kroppsställning. På samma sätt jämfördes E/É-kvoten mellan liggande och sittande. Resultaten från t-testet för både E/A och E/É-kvoten gav ett p-värde > 0,05. Detta resultat innebär att ingen signifikant skillnad i de diastoliska parametrarna vid liggande och sittande kunde påvisas statistiskt i denna studie. Nyckelord: Diastolisk dysfunktion, Diastolisk funktion, E/A-kvot, E/É-kvot, Fyllnadstryck, Kroppsställning, Preload, Pulsaddoppler teknik, Respiration, Vävnadsdoppler teknik.

Abstract [en]

COMPARISON OF DIASTOLIC PARAMETERS BETWEEN SUPINE POSTURE AND SITTING POSITION ZAHRAA ALSAFI Alsafi Z. Comparison of diastolic parameters between supine posture and sitting position. Degree Project, 15 Credit Points. Biomedical Laboratory Science, Malmö University: Health and Society, Department of Biomedical Laboratory Science, 2010. Changes in body position entails changes in cardiac diastolic function. Studies have shown that diastolic parameters are higher at supine posture in comparison with for example upright posture. The studies were made using non-invasive techniques performed by echocardiography. The change in the diastolic function arises because of variations in preload and filling pressures when changed body position. The purpose of this study was to measure the heart's diastolic parameters at supine posture and sitting position for a comparison. Pulsed doppler echocardiography and tissue doppler imaging were used to assess the diastolic parameters in 30 consecutive patients in the Cardiology clinic of Malmo, SUS. With pulsed doppler echocardiography the peak early mitral inflow velocity (E) and peak late filling velocity (A) were measured at the opening of mitral valve. An E/A ratio was calculated for all patients. On the contrary tissue doppler imaging was used to measure peak rate of early mitral annular velocity (E'). This value was measured at the septal and the lateral wall of the heart, and later an E'-average was calculated from these two measurements. With this value and the previously measured E-wave velocity, an E/É-ratio was calculated for all patients. Using t-test paired sample test a comparison between E/A ratio in supine posture and sitting position was made. A comparison was made in a similar way with the E/E'-ratio. Results from t-test for both E/A and E/E'-ratio gave a p-value >0.05. This result means that this study can not show a significant difference in the diastolic parameters at supine posture and sitting position. Key words: Body position, Diastolic dysfunction, Diastolic function, E/A ratio, E/É ratio, Filling pressure, Preload, Pulsed Doppler imaging, Respiration, Tissue Doppler imaging.

Place, publisher, year, edition, pages
Malmö högskola/Hälsa och samhälle , 2010.
Keywords [sv]
Diastolisk dysfunktion, Disatolisk funktion, E/A-kvot, E/E´-kvot, Fyllnadstryck, Kroppsställning, Preload, Pulsaddoppler teknik, Respiration, Vävnadsdoppler teknik
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-25512Local ID: 10873OAI: oai:DiVA.org:mau-25512DiVA, id: diva2:1487024
Educational program
HS Biomedicinsk laboratorievetenskap
Available from: 2020-11-03 Created: 2020-11-03 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

fulltext(339 kB)382 downloads
File information
File name FULLTEXT01.pdfFile size 339 kBChecksum SHA-512
0b4d4d61b3c34ec14bbf590f7d3cddac22b95f2feae43cd6f5da0f911091663101ee66749e2d62d0ff89a77e209390bbbd1efb8863c61b4c4ff531a71c2eb99e
Type fulltextMimetype application/pdf

By organisation
Faculty of Health and Society (HS)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 383 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 206 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf