Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Validering av Varicella Zoster virus och Herpes Simplex virus
Malmö University, Faculty of Health and Society (HS).
2018 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Syftet med denna valideringsstudie är att värdera lämpligheten att överföra den manuella analysen av aktuell infektion av Varicella Zoster Virus (aVZV IgM) och Herpes Simplex Virus (aHSV IgM) med SIEMENS Enzygnost® till en av de automatiserade analysinstrumenten EUROIMMUN Analyzer I (ELISA) eller DiaSorin LIAISON® XL. Arbetet utfördes på Klinisk Mikrobiologi i Lund. Konsekutiva serumprover för VZV IgM (n=108) och för HSV IgM (n=116) från det vardagliga flödet analyserades, tillsammans med 10 PCR- eller serokonversion-konfirmerade positiva serumprover av primär infektion VZV och HSV samt 10 positiva för reaktiverad infektion av VZV och HSV. Utöver det användes 10 serumprover konfirmerade positiva för Cytomegalovirus (CMV) respektive 10 för Epstein-Barr Virus (EBV) för att testa korsreaktionen metoderna emellan. Resultatet från VZV-valideringen i Analyzer I samt LIAISON® XL gav en överensstämmelse på 93% respektive 94% av de konsekutiva proverna, 71% respektive 86% av de primärinfekterade proverna och 75% respektive 58% av de reaktiverade proverna, samt en korsreaktivitet (positiva och gränsvärden) på totalt 33% respektive 20% av proverna. Resultatet från HSV-valideringen i Analyzer I samt LIAISON® XL gav en överensstämmelse på 84% respektive 87% av de konsekutiva proverna, 82% respektive 18% av de primärinfekterade proverna och 40% respektive 10% av de reaktiverade proverna, samt en korsreaktivitet (positiva och gränsvärden) på totalt 67% respektive 47% av proverna. Enligt rekommendation efter utförandet av denna studie så bör analysen av HSV IgM uteslutas från båda automatiserade metoder medan VZV IgM bör kontrolleras något ytterligare i Analyzer I, med förhoppning om att denna metod kan vara känsligare.

Abstract [en]

The approach of this validation study is to evaluate the adequacy for transferring the manual analysis method of ongoing infection of Varicella Zoster Virus (aVZV IgM) and Herpes Simplex Virus (aHSV IgM) with SIEMENS Enzygnost® to one of the automated instruments EUROIMMUN Analyzer I (ELISA) or DiaSorin LIAISON® XL. The study was carried out at Clinical Microbiology in Lund. Consecutive serum samples for VZV IgM (n=108) and HSV IgM (n=116) from the daily local flow of tests were analyzed, along with 10 positive for primary infection of VZV and HSV, confirmed by PCR or seroconversion, and 10 with reactivated infection of VZV and HSV. Beyond those, 10 serum samples confirmed positive for Cytomegalovirus (CMV) respectively 10 for Epstein-Barr Virus (EBV) to test the cross-reaction between the three methods. The results from the validation of VZV in Analyzer I and LIAISON® XL gave an agreement of 93% and 94% respectively in the consecutive tests, 71% and 86% respectively in the primary infected tests and 75% and 58% respectively in the reactivated tests, and also a cross-reactivity (both positive and in between-values) at a total of 33% respectively 20% of the tests. The results from the validation of HSV in Analyzer I and LIAISON® XL gave an agreement of 84% and 87% respectively in the consecutive tests, 82% and 18% respectively in the primary infected tests and 40% and 10% respectively in the reactivated tests, and also a cross-reactivity (both positive and in between-values) at a total of 67% respectively 47% of the tests. According recommendations after the performance of this study, the analysis of HSV IgM should be excluded from both of the automated methods while VZV IgM should be controlled further in Analyzer I, with hopes that this new method could be more sensitive.

Place, publisher, year, edition, pages
Malmö universitet/Hälsa och samhälle , 2018. , p. 23
Keywords [sv]
DiaSorin LIAISON® XL, EUROIMMUN Analyzer I, Herpes Simplex Virus, SIEMENS Enzygnost®, Validering, Varicella Zoster Virus
National Category
Biological Sciences
Identifiers
URN: urn:nbn:se:mau:diva-24474Local ID: 25625OAI: oai:DiVA.org:mau-24474DiVA, id: diva2:1485893
Educational program
HS Biomedicinsk laboratorievetenskap
Supervisors
Examiners
Available from: 2020-11-02 Created: 2020-11-02Bibliographically approved

Open Access in DiVA

fulltext(311 kB)345 downloads
File information
File name FULLTEXT01.pdfFile size 311 kBChecksum SHA-512
97d78ea98a3d20094123f718d90b0b4107aa1c700780557ab5bf6a4f00bb6669b4d695dc7ef1c1e9e1d6b466025bb0346ef6373d7a051aecae3420e729980191
Type fulltextMimetype application/pdf

By organisation
Faculty of Health and Society (HS)
Biological Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 346 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 308 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf