Malmö University Publications
System disruptions
There are recurring service disruptions on some of the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Impact of peri-implant buccal bone thickness, implant fixture diameter, abutment and/or prosthetic reconstruction material on the accuracy of Cone Beam Computed Tomography to assess peri-implant buccal bone level: an in vitro study in pig jaw
Malmö University, Faculty of Odontology (OD).
2018 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Abstract Aim: To evaluate the impact of peri-implant buccal bone thickness, implant fixture diameter, abutment material (Titanium Ti, Zirconium Zr) and/or prosthetic reconstruction material (metal ceramic vs ceramic) on the accuracy of Cone Beam Computed Tomography (CBCT) to assess peri-implant buccal bone level. Materials and methods: Titanium implants were inserted into 36 blocks of pig mandible in a way to create variable buccal bone thicknesses groups, each group with 12 blocks; group 1 (0.5-1 mm), group 2 (>1-1.5 mm) and group 3 (>1.5-2 mm), half of each group received a dehiscence which was created of variable extent. Two groups regarding abutment-crown material; (Ti abutment with CoCr crown, Zr abutment with Zr crown) and implant diameter; (standard/narrow) were assessed. Dehiscences were measured on CBCT image using 2 programs (i-Dixel and Photoshop) and were compared to the gold standard. Results: Thin buccal bone thickness group (0.5-1 mm) had major impact on the accuracy of CBCT to correctly detect and measure the extent of a bony dehiscence. No differences were detected between standard or narrow diameter implant and between TiTi/CoCr combination and TiZr/Zr combination in regards to possibility of CBCT to detect and evaluate accurately the extent of a bony dehiscence. Conclusion: Thin peri-implant buccal bone (≤ 1 mm) has a negative effect on the accuracy of CBCT to assess peri-implant buccal bone level. The possibility to identify and to assess the extent of peri-implant buccal bone dehiscence in CBCT was hardly affected by using different abutments and crown materials and different implant diameters.

Place, publisher, year, edition, pages
Malmö universitet/Odontologiska fakulteten , 2018.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-19922Local ID: 26517OAI: oai:DiVA.org:mau-19922DiVA, id: diva2:1479767
Educational program
OD Dental Science: Master Program
Supervisors
Examiners
Available from: 2020-10-27 Created: 2020-10-27 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Faculty of Odontology (OD)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 779 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf