Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Earth air heat exchanger, Trombe wall and green wall for passive heating and cooling in premium passive refugee house in Sweden
Malmö University, Faculty of Culture and Society (KS), Department of Urban Studies (US). Aalborg Univ, Dept Architecture Design & Media Technol, Aalborg, Denmark..ORCID iD: 0000-0001-7754-0927
Hokaido Univ, Environm Syst Engn Lab, Sapporo, Hokkaido, Japan.;Benha Univ, Shoubra Fac Engn, Banha, Egypt..
2020 (English)In: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 209, article id 112555Article in journal (Refereed) Published
Abstract [en]

With the increasing number of migrants and refugees, there is a need for energy-efficient and low impact temporary housing that can accommodate millions of displaced peoples worldwide. This study describes a design proposal for a premium passive refugee house that uses three main passive heating and cooling solutions (Earth Air Heat Exchanger, Trombe wall, and green wall) and is suited to the Swedish climate. The purpose of the combination of the three passive systems is to reduce cooling and heating loads to conserve a significant amount of primary energy and thus mitigate the impact of the house's energy use on the environment through a reduction in emissions. The house is designed to fulfill its energy needs from renewable sources and produce an annual surplus of 180 kWh/m(2)/annum. The methodology applied is a dynamic system modeling and simulation approach using TRNSYS and ANSYS software. The simulation results showed a heating load of 7.9 kWh/m(2)/annum and a cooling load of 2.8 kWh/m(2)/annum, with total energy consumption reaching 18.4 kWh/m(2)/annum. Preliminary feasibility costing showed a payback time of 7.4 years out of the 25-years suggested lifetime of building using the three passive solutions. The amount of CO2 emissions is 231.1 kg CO(2)e/annum with a primary energy demand of 0.032 GJ/m(2)/annum. As a follow-up to the initial study, a proof of concept has been implemented in Lund, Sweden, in an urban living lab to verify the simulation results through a 12-month post-occupancy monitoring and evaluation study.

Place, publisher, year, edition, pages
Elsevier, 2020. Vol. 209, article id 112555
Keywords [en]
Premium passive house, Refugee housing, CFD simulation, EAHE, Green wall, Trombe wall
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:mau:diva-17233DOI: 10.1016/j.enconman.2020.112555ISI: 000524307600019Scopus ID: 2-s2.0-85081006362OAI: oai:DiVA.org:mau-17233DiVA, id: diva2:1429802
Available from: 2020-05-12 Created: 2020-05-12 Last updated: 2024-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Dabaieh, Marwa

Search in DiVA

By author/editor
Dabaieh, Marwa
By organisation
Department of Urban Studies (US)
In the same journal
Energy Conversion and Management
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 327 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf