Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Accuracy of digital impressions of multiple dental implants: an in vitro study
Department of Periodontology, Oral Implantology, Removable and Implant Prosthetics, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.ORCID iD: 0000-0003-1004-0279
Department of Periodontology, Oral Implantology, Removable and Implant Prosthetics, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
Oral and Maxillofacial Imaging Unit, Dental School, University Hospital Ghent, Ghent, Belgium.
Malmö högskola, Faculty of Odontology (OD). Department of Periodontology, Oral Implantology, Removable and Implant Prosthetics, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
2017 (English)In: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 28, no 6, p. 648-653Article in journal (Refereed) Published
Abstract [en]

INTRODUCTION: Studies demonstrated that the accuracy of intra-oral scanners can be compared with conventional impressions for most indications. However, little is known about their applicability to take impressions of multiple implants. AIM: The aim of this study was to evaluate the accuracy of four intra-oral scanners when applied for implant impressions in the edentulous jaw. MATERIAL AND METHODS: An acrylic mandibular cast containing six external connection implants (region 36, 34, 32, 42, 44 and 46) with PEEK scanbodies was scanned using four intra-oral scanners: the Lava C.O.S. and the 3M True Definition, Cerec Omnicam and 3Shape Trios. Each model was scanned 10 times with every intra-oral scanner. As a reference, a highly accurate laboratory scanner (104i, Imetric, Courgenay, Switzerland) was used. The scans were imported into metrology software (Geomagic Qualify 12) for analyses. Accuracy was measured in terms of trueness (comparing test and reference) and precision (determining the deviation between different test scans). Mann-Whitney U-test and Wilcoxon signed rank test were used to detect statistically significant differences in trueness and precision respectively. RESULTS: The mean trueness was 0.112 mm for Lava COS, 0.035 mm for 3M TrueDef, 0.028 mm for Trios and 0.061 mm for Cerec Omnicam. There was no statistically significant difference between 3M TrueDef and Trios (P = 0.262). Cerec Omnicam was less accurate than 3M TrueDef (P = 0.013) and Trios (P = 0.005), but more accurate compared to Lava COS (P = 0.007). Lava COS was also less accurate compared to 3M TrueDef (P = 0.005) and Trios (P = 0.005). The mean precision was 0.066 mm for Lava COS, 0.030 mm for 3M TrueDef, 0.033 mm for Trios and 0.059 mm for Cerec Omnicam. There was no statistically significant difference between 3M TrueDef and Trios (P = 0.119). Cerec Omnicam was less accurate compared to 3M TrueDef (P < 0.001) and Trios (P < 0.001), but no difference was found with Lava COS (P = 0.169). Lava COS was also less accurate compared to 3M TrueDef (P < 0.001) and Trios (P < 0.001). CONCLUSIONS: Based on the findings of this in vitro study, the 3M True Definition and Trios scanner demonstrated the highest accuracy. The Lava COS was found not suitable for taking implant impressions for a cross-arch bridge in the edentulous jaw.

Place, publisher, year, edition, pages
John Wiley & Sons, 2017. Vol. 28, no 6, p. 648-653
Keywords [en]
dental implant, digital impression, edentulous, intra-oral scan
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-15288DOI: 10.1111/clr.12853ISI: 000404776400003PubMedID: 27150731Scopus ID: 2-s2.0-84966430692Local ID: 23086OAI: oai:DiVA.org:mau-15288DiVA, id: diva2:1418809
Available from: 2020-03-30 Created: 2020-03-30 Last updated: 2024-11-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopushttp://onlinelibrary.wiley.com/doi/10.1111/clr.12853/pdf

Authority records

Vandeweghe, Stefan

Search in DiVA

By author/editor
Vandeweghe, Stefan
By organisation
Faculty of Odontology (OD)
In the same journal
Clinical Oral Implants Research
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 45 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf