Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing
Show others and affiliations
2013 (English)In: The Journal of Craniofacial Surgery, ISSN 1049-2275, E-ISSN 1536-3732, Vol. 24, no 3, p. 860-865Article in journal (Refereed) Published
Abstract [en]

The aim of this study was to evaluate histologically and biomechanically the peri-implant bone healing around implants placed with high torque after a follow-up of 8 and 12 weeks. A total of 12 implants were placed in the lower edge of the mandible of 2 sheep. In each sheep, 3 implants were placed with a low torque (<25 N center dot cm, LT group) as a control, and 3 implants were placed with a high insertion torque (maximum torque, HT group). The sheep were killed after 8 and 12 weeks of healing, and the implants were examined for removal torque, resonance frequency analysis, and histologic analysis. The mean insertion torque in the LT group was 24 N center dot cm, whereas it was 105.6 N center dot cm in HT. All the implants osseointegrated and histologic analysis showed similar aspects of the peri-implant bone tissue for both groups and both healing times. Mean removal torque values for LT implants were 159.5 and 131.5 N center dot cm after 8 and 12 weeks, respectively, whereas those for the HT were 140 and 120 N center dot cm at 8 and 12 weeks, respectively. Implant stability quotient values were 26.6 and 76 for the LT group and 74 and 76 for the HT group at 8 and 12 weeks, respectively. It could be concluded that high implant insertion torque does not induce adverse reaction in cortical bone and does not lead to implant failure.

Place, publisher, year, edition, pages
Lippincott Williams & Wilkins, 2013. Vol. 24, no 3, p. 860-865
Keywords [en]
Dental implant, insertion torque, peri-implant bone
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-6148DOI: 10.1097/SCS.0b013e31827ca3cfISI: 000330078200086PubMedID: 23714897Scopus ID: 2-s2.0-84880089120Local ID: 27574OAI: oai:DiVA.org:mau-6148DiVA, id: diva2:1403037
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-12-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Galli, Silvia

Search in DiVA

By author/editor
Galli, Silvia
By organisation
Faculty of Odontology (OD)
In the same journal
The Journal of Craniofacial Surgery
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 74 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf