Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Clinical performance of a conometric retention system for single implant restorations: 1-year analysis of a prospective multicenter study
Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Goethe University, University Hospital Frankfurt, Frankfurt am Main, Germany; Private Practice for Oral Surgery and Implant Dentistry, Academic Teaching and Research Institution of the Johann Wolfgang Goethe University Frankfurt am Main, Ludwigshafen, Germany.ORCID iD: 0000-0002-0412-5615
Private Practice for Oral Surgery and Implant Dentistry, Academic Teaching and Research Institution of the Johann Wolfgang Goethe University Frankfurt am Main, Ludwigshafen, Germany.ORCID iD: 0000-0003-4701-0874
Clinica Dental Antuña de Alaiz, Oviedo, Spain.
The Implant Experts, Maidstone, UK.
Show others and affiliations
2026 (English)In: International Journal of Implant Dentistry, E-ISSN 2198-4034, Vol. 12, no 1, article id 41Article in journal (Refereed) Published
Abstract [en]

PURPOSE: Conventional screw- and cement-retained single implant restorations are associated with biological and technical complications. Friction-retained conometric concepts have been proposed as an alternative; however, clinical evidence for single crowns, particularly from prospective multicenter studies, remains limited. This study evaluated the 1-year clinical performance of a conometric retention system for implant-supported single crowns.

METHODS: This prospective multicenter study was conducted at nine clinical centers in Europe and North America. Subjects requiring single-tooth replacement in the maxilla or mandible received one implant restored with a prefabricated 5.9° conometric abutment and a titanium nitride-coated coping. All-ceramic crowns were extraorally bonded and seated without cement or screws. Radiographs were obtained at implant placement, delivery of the permanent restoration, and after 1 year. Primary outcomes were implant and prosthetic survival. Secondary outcomes included marginal bone level (MBL) changes, bleeding on probing, plaque, probing pocket depth, and complication rates. Descriptive statistics and confidence intervals were calculated.

RESULTS: A total of 144 implants were included in the per-protocol analysis. Three implants failed after delivery of the permanent restoration, resulting in a 1-year implant survival rate of 96.7%. Of 131 restorations evaluated at 1 year, 4 showed irreversible loss of conometric retention and were classified as prosthetic failures. In total, 22 prosthetic complication events were recorded, including 18 reversible technical complications (12.5%) and 4 irreversible failures, corresponding to an overall complication rate of 15.3%. Mean MBL change was - 0.11 mm from implant placement to PR and - 0.02 mm from PR to 1 year.

CONCLUSIONS: Within the limitations of this 1-year analysis, the investigated conometric retention system demonstrated high implant and prosthetic survival rates and limited marginal bone changes. However, a clinically relevant incidence of technical complications, including irreversible loss of conometric retention, was observed during the first year of function. These findings suggest that the conometric concept may require careful case selection and clinical monitoring. Long-term follow-up is required to further evaluate the clinical stability and prosthetic reliability of this retention concept over time.

TRIAL REGISTRATION: ClinicalTrials.gov, ID, NCT04063878, August 20, 2019.

Place, publisher, year, edition, pages
Springer Nature , 2026. Vol. 12, no 1, article id 41
Keywords [en]
Humans, Prospective Studies, Dental Implants, Single-Tooth, Crowns, Dental Prosthesis Retention / methods, Dental Prosthesis, Implant-Supported, Female, Male, Middle Aged, Dental Restoration Failure, Dental Prosthesis Design, Treatment Outcome, Conometric retention, Friction-fit abutment, Implant-supported restoration, Marginal bone level, Peri-implant disease, Prosthetic complications, Single implant crown
National Category
Odontology
Identifiers
URN: urn:nbn:se:mau:diva-87825DOI: 10.1186/s40729-026-00708-zISI: 001853685000001PubMedID: 42616267OAI: oai:DiVA.org:mau-87825DiVA, id: diva2:2096610
Available from: 2026-08-31 Created: 2026-08-31 Last updated: 2026-09-03Bibliographically approved

Open Access in DiVA

fulltext(2705 kB)31 downloads
File information
File name FULLTEXT01.pdfFile size 2705 kBChecksum SHA-512
0584f9c1eb9f42cf68c2f777b5f465ef266075ef4d806856c0f5e5d911e229d96103910e62c9a8074bc1bc72ad8d31366fb085e080a841b33773cca21c4f4ec0
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Toia, Marco

Search in DiVA

By author/editor
Gehrke, PeterWeinhold, OctavioCooper, LyndonToia, Marco
By organisation
Faculty of Odontology (OD)
In the same journal
International Journal of Implant Dentistry
Odontology

Search outside of DiVA

GoogleGoogle Scholar
Total: 31 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 326 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf