Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The Impact of Operator Access on Implant Surface Roughness Following Implantoplasty Procedures: A Laboratory Study
Department of Restorative Dentistry and Periodontology, Dublin Dental University Hospital, Trinity College, University of Dublin, Dublin, Ireland.
Malmö University, Faculty of Technology and Society (TS), Department of Materials Science and Applied Mathematics (MTM).ORCID iD: 0000-0002-0043-9545
Department of Biostatistics, Dublin Dental University Hospital, Trinity College, University of Dublin, Dublin, Ireland.ORCID iD: 0000-0001-6374-5016
Department of Restorative Dentistry and Periodontology, Dublin Dental University Hospital, Trinity College, University of Dublin, Dublin, Ireland.ORCID iD: 0000-0002-8783-8089
Show others and affiliations
2026 (English)In: Clinical and Experimental Dental Research, E-ISSN 2057-4347, Vol. 12, no 2, article id e70336Article in journal (Refereed) Published
Abstract [en]

Objectives: To evaluate the influence of operator access on surface roughness parameters and material loss following implantoplasty (IP).

Material and Methods: A total of 42 dental implants were utilized in this study, and three different implant designs. Two set-ups were used: a table-top, allowing unrestricted access, and a phantom-head, imposing limitations in access and better replicating the clinical situation. A combination of tungsten carbide burs and silicone polishers was used to perform IP on the implants. The total amount of time required for IP of each implant was measured for comparisons between modalities, and a 2D roughness profile analysis (Ra and Rz) was conducted using a contact stylus profilometer. The weight and the diameter of the implants were also measured before and after IP was performed.

Results: A statistically significant difference was found between the Ra (p = 0.004) and Rz (p = 0.019) values of implants prepared under table-top conditions, being smoother, when compared to the ones prepared in the phantom head. The time required to perform IP was significantly different between the two different settings (p < 0.001) and between some implant types. The set-up in which IP was performed did not have a significant impact on the change in implant mass (p = 0.926) or in implant diameter (p = 0.721).

Conclusions: Implants treated with IP in the phantom-head set-up exhibited significantly greater surface roughness and required longer procedural time compared to those treated in the table-top model, but did not influence material loss.

Place, publisher, year, edition, pages
Wiley , 2026. Vol. 12, no 2, article id e70336
National Category
Odontology
Identifiers
URN: urn:nbn:se:mau:diva-83262DOI: 10.1002/cre2.70336ISI: 001720789800001PubMedID: 41849691Scopus ID: 2-s2.0-105033107993OAI: oai:DiVA.org:mau-83262DiVA, id: diva2:2047941
Available from: 2026-03-23 Created: 2026-03-23 Last updated: 2026-04-07Bibliographically approved

Open Access in DiVA

fulltext(1541 kB)67 downloads
File information
File name FULLTEXT01.pdfFile size 1541 kBChecksum SHA-512
bcab5bf23ce4131b33b416d26b111f466e02a123c4dd237955307b7e075af982253255f17cb20fdeb3bfc344869ef8ae7cd0441c714ba033065d90b2047b53c8
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Krause, Andreas M.Stavropoulos, Andreas

Search in DiVA

By author/editor
Krause, Andreas M.Honari, BahmanWinning, LewisStavropoulos, AndreasPolyzois, Ioannis
By organisation
Department of Materials Science and Applied Mathematics (MTM)Faculty of Odontology (OD)
In the same journal
Clinical and Experimental Dental Research
Odontology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 609 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf