Malmö University Publications
System disruptions
We are currently experiencing disruptions on the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Comparison of absorbed doses and organ doses measured with thermoluminescent dosimeters and Gafchromic film for cone beam computed tomography examination of the posterior mandibular region in a head phantom
Malmö University, Faculty of Odontology (OD).ORCID iD: 0000-0003-4611-3708
Medical Radiation Physics, Karolinska University Hospital, Stockholm, Sweden.
Department of Medical Radiation Physics, Lund University, Malmö, Sweden.
Malmö University, Faculty of Odontology (OD). Specialized Pain Rehabilitation, Skåne University Hospital, Lund, Sweden; Scandinavian Center for orofacial Neurosciences.ORCID iD: 0000-0002-8539-7742
Show others and affiliations
2023 (English)In: Oral surgery, oral medicine, oral pathology and oral radiology, ISSN 2212-4403, E-ISSN 2212-4411, Vol. 136, no 6, p. 769-776Article in journal (Refereed) Published
Abstract [en]

Objectives: We aimed to map the correlation between thermoluminescent dosimeters (TLDs) and Gafchromic film for measuring absorbed doses and to compare minimum, maximum, and mean absorbed doses over larger regions of interest and at various craniofacial organs and tissues during cone beam computed tomography (CBCT) exposure of the mandibular third molar region.

Study design: We positioned TLDs at 75 measurement points in a head phantom. Gafchromic film was cut to the same shape as the 5 levels of the phantom and was placed on top of the TLDs. Both dosimetry methods thus included the surface of each level simultaneously. CBCT scans were made using a 5 × 5 cm field of view and a rotation angle of 200°. Measurements included absorbed dose distributions, doses at all 75 points, and minimum, maximum, and mean doses within organs and tissues.

Results: The correlation of point-dose measurements at all TLD sites with doses measured on film was strong (R2 = 0.9687), with greatest correlation at lower doses (<2 mGy). Large deviations between TLD and film measurements of minimum and maximum doses and absorbed doses to the organs occurred at all 5 levels. TLD positioning failed to cover several organ sites; for these, only absorbed dose measurements from the film were available.

Conclusions: TLDs were unable to sample dose distributions and gradients accurately. The characteristics of Gafchromic LD-V1 film make it a favorable alternative in dental CBCT dosimetry.

Place, publisher, year, edition, pages
Elsevier , 2023. Vol. 136, no 6, p. 769-776
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-62210DOI: 10.1016/j.oooo.2023.07.006ISI: 001133164600001PubMedID: 37625926Scopus ID: 2-s2.0-85168847369OAI: oai:DiVA.org:mau-62210DiVA, id: diva2:1792910
Available from: 2023-08-30 Created: 2023-08-30 Last updated: 2024-11-11Bibliographically approved
In thesis
1. Radiographic imaging in relation to the mandibular third molar: tooth characteristics, modality choice, optimization, and absorbed dose
Open this publication in new window or tab >>Radiographic imaging in relation to the mandibular third molar: tooth characteristics, modality choice, optimization, and absorbed dose
2023 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Radiographic imaging of the mandibular third molar (M3) is a valuable diagnostic tool. It provides information on tooth position, root morphology, and relations to surrounding anatomical structures that facilitates diagnosis and treatment planning. Three modalities are commonly used in dentistry: intraoral and panoramic radiography, and cone beam computed tomography (CBCT). Over time, panoramic radiography became a justified choice in most cases of M3 removal. In the last decade, a three-dimensional (3D) alternative, CBCT, has seen increasing use. The advantages of 3D come at the cost of higher radiation doses and societal expense. The four studies in this thesis originated from current knowledge gaps and clinical needs.

The use of panoramic radiography for evaluating the M3 and its relation to the inferior alveolar nerve (IAN) is well-established practice; however, its application has declined over time, possibly due to the rising popularity of CBCT imaging. Thus, it is of interest to investigate the suitability of panoramic imaging of the M3. Choice of imaging modality is important from dose delivery and socioeconomic standpoints. A survey of clinician experiences and preferences in imaging modalities for pre-surgical analysis was needed.

In diagnostic imaging, the common goal is to reduce radiation exposure to the lowest threshold that still delivers reliable diagnostic information. Due to the growing use of CBCT, there is a need to optimize exposure settings and use reliable measurement methods in dosimetric analysis. Nevertheless, for the M3, the present literature has neither evaluated a low-dose protocol in a clinical setting nor compared the standard method of measuring absorbed dose in dental CBCT with an alternative method.

This thesis is based on the following papers:

Paper I, an observational study, evaluated M3 characteristics and IAN relation, incidental findings, and image quality regarding patient positioning on 442 panoramic radiographs. 

Key findings: A majority of M3s were erupted and vertically positioned, regardless of age. The IAN was located inferior to the roots in just over half of the cases; an overlapping position was most common if the tooth was retained or semi-retained, or patient age less than 30 years. Frequent incidental findings were apical radiolucencies, idiopathic osteosclerosis, and tooth fragments. Patient positioning was suboptimal in one-third of the radiographs; common errors included patient placement posterior to the image layer and an upward-tilted head. 

Paper II was a web-based questionnaire sent to general dentists and to residents and specialists in oral and maxillofacial surgery. The survey comprised multiple-choice questions with four M3 cases depicted in images. 

Key findings: A majority of respondents received a report within 2 weeks of their CBCT referral and would read it and view the images before surgery; one-third did not. Panoramic radiographs were the preferred modality in pre-surgical planning; differences between professions were significant. Panoramic radiographs and CBCT were seen as facilitating treatment planning, and CBCT as also reducing post-operative complications. CBCT tended to be preferred in more complex M3 cases. 

Paper III was a clinical trial investigating an alternative, low-dose CBCT protocol with lower tube current than the default protocol. After justification for CBCT, 48 patients (62 M3s) referred for a pre-surgical investigation were recruited. Two scans of each site were made using the two protocols

Key findings: No significant differences occurred in visibility of root and mandibular canal relationship and proximity, root morphology, and possible root resorption of the second molar. Visibility of the periodontal ligament was significantly better in default images. Subjective image quality in low-dose images (60% less radiation) was acceptable in most cases. 

Paper IV was a laboratory study comparing two dosimeters in a CBCT scan of the M3 region. Five slices of an anthropomorphic phantom were prepared with thermoluminescent dosimeters (TLD-100) at 75 sites and covered with Gafchromic film LD-V1. 

Key findings: Point dose measurements at all TLD sites correlated well with doses measured on film; agreement was better at lower doses. Minimum and maximum doses on film versus at TLD sites deviated greatly on all slices and for several organs. 

To conclude, panoramic radiography is useful in evaluating M3 and IAN relationships. Clinicians consider pre-surgical information to differ depending on imaging modality; modality preference seems to depend on case complexity. Optimized CBCT protocols can be used for the M3. Gafchromic film is a favorable alternative in dental CBCT dosimetry

Place, publisher, year, edition, pages
Malmö: Malmö University Press, 2023. p. 89
Series
Malmö University Odontological Dissertations, ISSN 1650-6065
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-62211 (URN)10.24834/isbn.9789178773534 (DOI)978-91-7877-352-7 (ISBN)978-91-7877-353-4 (ISBN)
Public defence
2023-09-29, Aulan, Tandvårdshögskolan Malmö universitet, Smedjegatan 16, Malmö, 09:15 (Swedish)
Opponent
Supervisors
Available from: 2023-08-31 Created: 2023-08-31 Last updated: 2024-02-26Bibliographically approved

Open Access in DiVA

fulltext(1197 kB)1240 downloads
File information
File name FULLTEXT01.pdfFile size 1197 kBChecksum SHA-512
2ccc3725ae340b160cef9f789b5147918f058094fae2b14e0c6c3509b44b871cb47106da3eb1b863d18ff47adbd8046495a322b5c739f1a8518f84b943b82217
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Cederhag, JosefineAlstergren, PerShi, Xie-QiHellén-Halme, Kristina

Search in DiVA

By author/editor
Cederhag, JosefineAlstergren, PerShi, Xie-QiHellén-Halme, Kristina
By organisation
Faculty of Odontology (OD)
In the same journal
Oral surgery, oral medicine, oral pathology and oral radiology
Dentistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 1242 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 205 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf