Publikationer från Malmö universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Hydrogen Peroxide Detection Using Prussian Blue-modified 3D Pyrolytic Carbon Microelectrodes
Tech Univ Denmark, Natl Ctr Nano Fabricat & Characterizat, DTU Nanolab, Orsteds Plads,Bldg 347, DK-2800 Lyngby, Denmark..
Tech Univ Denmark, Natl Ctr Nano Fabricat & Characterizat, DTU Nanolab, Orsteds Plads,Bldg 347, DK-2800 Lyngby, Denmark..
Tech Univ Denmark, Natl Ctr Nano Fabricat & Characterizat, DTU Nanolab, Orsteds Plads,Bldg 347, DK-2800 Lyngby, Denmark..
Copenhagen Univ Hosp Herlev Gentofte, Allergy Clin, Gentofte Hosp Vej 8, DK-2900 Hellerup, Denmark..
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Electroanalysis, ISSN 1040-0397, E-ISSN 1521-4109, Vol. 33, nr 12, s. 2516-2528Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A highly sensitive amperometric Prussian blue-based hydrogen peroxide sensor was developed using 3D pyrolytic carbon microelectrodes. A 3D printed multielectrode electrochemical cell enabled simultaneous highly reproducible Prussian blue modification on multiple carbon electrodes. The effect of oxygen plasma pre-treatment and deposition time on Prussian blue electrodeposition was studied. The amperometric response of 2D and 3D sensors to the addition of hydrogen peroxide in mu M and sub-mu M concentrations in phosphate buffer was investigated. A high sensitivity comparable to flow injection systems and a detection limit of 0.16 mu M was demonstrated with 3D pyrolytic carbon microelectrodes at stirred batch condition

Ort, förlag, år, upplaga, sidor
John Wiley & Sons, 2021. Vol. 33, nr 12, s. 2516-2528
Nyckelord [en]
Prussian blue, hydrogen peroxide sensor, amperometry, pyrolytic carbon
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:mau:diva-46749DOI: 10.1002/elan.202100387ISI: 000706293400001Scopus ID: 2-s2.0-85116907680OAI: oai:DiVA.org:mau-46749DiVA, id: diva2:1609746
Tillgänglig från: 2021-11-09 Skapad: 2021-11-09 Senast uppdaterad: 2024-02-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Ruzgas, Tautgirdas

Sök vidare i DiVA

Av författaren/redaktören
Ruzgas, TautgirdasSylvest Keller, Stephan
Av organisationen
Biofilms Research Center for BiointerfacesInstitutionen för biomedicinsk vetenskap (BMV)
I samma tidskrift
Electroanalysis
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 111 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf