Accuracy of cone beam computed tomography is limited at implant sites with a thin buccal bone: A laboratory study
Malmö University, Faculty of Odontology (OD).
Malmö University, Faculty of Odontology (OD).ORCID iD: 0000-0002-8279-7943
Malmö University, Faculty of Odontology (OD).
Aarhus University.
Show others and affiliations
2021 (English)In: Journal of Periodontology, ISSN 0022-3492, E-ISSN 1943-3670, Vol. 92, no 4, p. 592-601Article in journal (Refereed) Published
Abstract [en]

Background: To evaluate whether buccal bone thickness (BBT), implant diameter, and abutment/crown material influence the accuracy of cone beam computed tomography (CBCT) to determine the buccal bone level at titanium implants.

Methods: Two implant beds (i.e., narrow and standard diameter) were prepared in each of 36 porcine bone blocks. The implant beds were positioned at a variable distance from the buccal bone surface, thus resulting in 3 BBT groups (i.e., > 0.5-1.0; > 1.0-1.5; > 1.5-2.0 mm). In half of the blocks, a buccal bone dehiscence of random extent ("depth") was created and implants were mounted with different abutment/crown material (i.e., titanium abutments with a metal-ceramic crown and zirconia abutments with an all-ceramic zirconia crown). The distance from the implant shoulder to the buccal bone crest was measured on cross-sectional CBCT images and compared to the direct measurements at the bone blocks.

Results: While abutment/crown material and implant diameter had no effect on the detection accuracy of the buccal bone level at dental implants in CBCT scans, BBT had a significant effect. Specifically, when BBT was ≤ 1.0 mm, a dehiscence was often diagnosed although not present, i.e., the sensitivity was high (95.8%), but the specificity (12.5%) and the detection accuracy (54.2%) were low. Further, the average measurement error of the distance from the implant shoulder to the buccal bone crest was 1.6 mm.

Conclusions: Based on the present laboratory study, BBT has a major impact on the correct diagnosis of the buccal bone level at dental titanium implants in CBCT images; in cases where the buccal bone is ≤ 1 mm thick, detection of the buccal bone level is largely inaccurate. This article is protected by copyright. All rights reserved.

Place, publisher, year, edition, pages
John Wiley & Sons, 2021. Vol. 92, no 4, p. 592-601
Keywords [en]
alveolar process, cone-beam computed tomography, dental implants, titanium, zirconium
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-18158DOI: 10.1002/JPER.20-0222ISI: 000569443500001PubMedID: 32846005Scopus ID: 2-s2.0-85090991592OAI: oai:DiVA.org:mau-18158DiVA, id: diva2:1462836
Available from: 2020-08-31 Created: 2020-08-31 Last updated: 2024-02-26Bibliographically approved

Open Access in DiVA

fulltext(787 kB)114 downloads
File information
File name FULLTEXT01.pdfFile size 787 kBChecksum SHA-512
52c65f54a3086e8e658d25b3e083463aa2a768d56d670b69418e6fd70c29d426e4058e6dc58bd4d689a222376ca69c84fc7212786defd0797499917d9b8d2d41
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Bertl, KristinaHellén-Halme, KristinaStavropoulos, Andreas

Search in DiVA

By author/editor
Bertl, KristinaHellén-Halme, KristinaStavropoulos, Andreas
By organisation
Faculty of Odontology (OD)
In the same journal
Journal of Periodontology
Dentistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 114 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 79 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf