On core and bi-layered all-ceramic fixed dental prostheses, design and mechanical properties: studies on stabilized zirconiumdioxide
Malmö högskola, Faculty of Odontology (OD).ORCID iD: 0000-0002-9387-5222
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Loss of teeth can affect a person’s self-esteem, social life, appearance and oral function. Reconstruction of a missing tooth has scientifically been shown to increase self-esteem and quality of life and to maintain oral function. For many patients a fixed dental prostheses (FDP) is preferred, either tooth- or implant-supported. Improvement and development of all-ceramic materials have made them preferable to other alternatives. However, despite properties of dental ceramics’ well known biocompatibility, good chemical and mechanical, the materials have their weaknesses, such as brittleness and some difficulties with the layering porcelain. Many all-ceramic materials cannot withstand minor flexure; more than 0.1 - 0.3 %, will lead to fracture. Oxide-ceramic, specifically yttria stabilized tetragonal zirconia polycrystals (Y-TZP) has become the most commonly used all-ceramic material. This material has the potential to be used for larger restorations. In addition, one of many challenges is to ensure durable zirconia-based restorations in the oral cavity. In the clinical situation, crowns and bridges are supported by a combination of different structures with differing properties, i.e. bone, dentine and enamel. The complexity of the supporting tissues in the oral cavity creates stress patterns in the prosthetic material, which need to be considered when designing a dental restoration. The durability of all-ceramic FDPs is dependent on knowledge of the material and design of the FDPs. In particular the design, shape of the connector and the radius of curvature at the gingival embrasure play a significant role in the load-bearing capacity of FDPs. The overall aim of this thesis is to evaluate design of zirconia-based restorations in relation to achieving increased fracture resistance. Another aim is related to how the choice of material used for supporting tooth analogues in the test set-up and how this influences test results relating to fracture strength of all-ceramic FDPs. Study I evaluates different radii (0.60 and 0.90 mm) of curvature in the embrasure of the connector area and different connector dimensions (2 x 2, 3 x 2 and 3 x 3 mm) and their effects on the fracture resistance of 3-unit all-ceramic FPDs made of Y-TZP. The results show that by increasing the radius of the gingival embrasure from 0.6 to 0.9 mm, the fracture strength for a Y-TZP FPD with connector dimension 3 x 3 mm will increase by 20%. Study II investigated how the choice of material (aluminium, polymer and DuraLay) used for supporting tooth analogues and support complexity influence test results concerning the fracture strength of FDPs made of a brittle material Y-TZP. The outcome of the study demonstrated that Y-TZP FDPs cemented on tooth analogues made of aluminium, with high E-modulus showed a significantly higher load at fracture and a different fracture mode than shown in clinical situations. Study III evaluates how factors as different default settings for connector design of two different CAD/CAM systems and different radii of curvature in the embrasure area of the connector will affect the fracture strength and the fracture mode of 3-unit, i.e. 4-unit allceramic FDPs made from Y-TZP and further to investigate how the number of pontics affect the fracture strength of Y-TZP. The results showed that the most crucial factor for the load-bearing capacity is the design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice. Study IV investigate and compare the fracture strength and fracture mode in 11 groups of the currently most used multilayer all-ceramic systems for Y-TZP FDPs, with respect to the choice of core material, veneering material area, manufacturing technique (split-file, overpress, built-up porcelains and glass-ceramics), design of connectors and radius of curvature of FDP cores. The results show that the design of a framework is a crucial factor for the load bearing capacity of an all-ceramic FDP. The state-of-the-art designs are preferable, since the split-file designed cores call for a cross-sectional connector area, at least 42% larger, to have the same load bearing capacity as the state-of-the-art designed cores. Analyses of the fracture patterns demonstrated differences between the milled veneers and over-pressed or built-up veneers, where the milled ones showed numerically more veneer cracks whereas the other groups only showed complete connector fractures. All veneering materials/techniques tested were found, with great safety margin to be sufficient for clinical use both anteriorly and posteriorly.

Place, publisher, year, edition, pages
Malmö University, Faculty of Odontology , 2015. , p. 102
Series
Doctoral Dissertation in Odontology
Keywords [en]
Y-TZP, Zirconia, All-ceramic FDPs, connector design, radius, state-of-the-art, CAD/CAM, multi-layer technique, veneering ceramic, split-file, over-pressing, dental porcelain, MECHANICAL PROPERTIES
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-7703Local ID: 18473ISBN: 9789171044051 (print)ISBN: 9789171044068 (print)OAI: oai:DiVA.org:mau-7703DiVA, id: diva2:1404643
Note

Note: The papers are not included in the fulltext online.

Paper IV in dissertation as manuscript.

Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2025-01-08Bibliographically approved
List of papers
1. Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design
Open this publication in new window or tab >>Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design
2009 (English)In: Swedish Dental Journal, ISSN 0347-9994, Vol. 33, no 3, p. 149-159Article in journal (Refereed) Published
Abstract [en]

True crystalline ceramic materials presently used in restorative dentistry are Al2O3 (alumina) and yttrium-oxide stabilised tetragonal polycrystalline zirconium-dioxide (Y-TZP). To ensure optimal clinical performance, the dimensions of the Fixed Partial Denture (FPD) framework in general and of the connectors in particular, must be adequate. Considered recommendations for connector dimensions for Y-TZP FPDs vary from 2 to 4 mm in occluso-gingival height and 2 to 4 mm in bucco-lingual width. In order to reduce the fracture probability when designing all-ceramic FPDs, the shape of the connector is an important factor to consider. The radius of curvature at the gingival embrasure plays a significant role in the load-bearing capacity. FPDs with small gingival embrasure radii are subjected to high stress concentrations in the connector area during loading, compared to FPDs with large embrasure radii. The aim of this in-vitro study was to investigate how different radii of curvature in the embrasure of the connector area and different connector dimensions could affect the fracture resistance of 3-unit all-ceramic FPDs made of Y-TZP. Forty-eight FPDs in 6 groups of 8 FPDs with different connector design were produced in Procera Zirconia Bridge material. The FPD cores were subjected to heat treatment to simulate veneering. Following cementation, the FPDs were firstly thermocycled for 5,000 cycles, then preloaded for 10,000 cycles and finally loaded to fracture. All the FPDs fractured in the connector area. All the crack propagation which led to fracture started at the gingival embrasure of the connector. Within the limitations of this in-vitro study,the recommended minimum dimension of an anterior 3-unit all-ceramic FPD of Y-TZP is 3 mm in incisal-cervical direction and 2 mm in buccal-lingual direction. By increasing the radius of the gingival embrasure from 0.6 to 0.9 mm, the fracture strength for a Y-TZP FPD with connector dimension 3 x 3 mm increases by 20%.

Place, publisher, year, edition, pages
Swedish dental association, 2009
Keywords
denture design, fixed partial denture, dental clasps, material testing, zirconium, yttrium
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-5925 (URN)000271525300007 ()19994565 (PubMedID)2-s2.0-70449442850 (Scopus ID)9913 (Local ID)9913 (Archive number)9913 (OAI)
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2025-01-08Bibliographically approved
2. The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental prostheses
Open this publication in new window or tab >>The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental prostheses
2011 (English)In: Acta Odontologica Scandinavica, ISSN 0001-6357, E-ISSN 1502-3850, Vol. 69, no 4, p. 229-237Article in journal (Refereed) Published
Abstract [en]

Objective: When a new material is released, clinical studies are indicated. For the clinical studies to be defensible, in-vitro studies, as clinically relevant as possible, must be performed. The aim of the present study was to investigate how the choice of material used for supporting tooth analogues and support complexity influence test results concerning the fracture strength of FDPs made of a brittle material Y-TZP. Material and methods: Twenty-four FDPs were produced in Y-TZP. The FDP cores were subjected to heat treatment to simulate veneering and then thermocycled for 5,000 cycles to simulate ageing. The FDPs were divided into 3 groups and were cemented on tooth-supporting analogues made from aluminium, polymer and DuraLay®. The FDPs were preloaded for 10,000 cycles and finally loaded to fracture. Results: There were no significant differences in load-to- fracture and fracture mode between the groups cemented on polymer and DuraLay® tooth analogues. The FDPs cemented on aluminium tooth analogues showed a significantly higher load at fracture and a different fracture mode. Conclusions: Within the limitations of this in-vitro study the following could be concluded: to achieve mutually comparable results there is a need for a standardised, simple test set-up for in-vitro testing of all-ceramic FDPs intended for cementation upon natural teeth. Resilient, non-complex and resilient complex tooth analogues give comparable test results when the test set-up is unchanged in all other aspects. Non-resilient (with an e-modulus of aluminium or higher) tooth analogues give high and unrealistic load-at-fracture values together with adverse fracture modes compared to FDPs failing in clinical situations.

Place, publisher, year, edition, pages
Taylor & Francis, 2011
Keywords
Y-TZP, All-ceramic, Dental porcelain, Fixed Dental Prostheses, Y-TZP
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-6816 (URN)10.3109/00016357.2010.549508 (DOI)000291944600006 ()21231816 (PubMedID)2-s2.0-79959526917 (Scopus ID)13195 (Local ID)13195 (Archive number)13195 (OAI)
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2025-01-08Bibliographically approved
3. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history.
Open this publication in new window or tab >>Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history.
2013 (English)In: Swedish Dental Journal, ISSN 0347-9994, Vol. 37, no 4, p. 179-187Article in journal (Refereed) Published
Abstract [sv]

Brotthållfasthet hos helkeramiska (Y-TZP) tre och fyra-leds broskelett: betydelsen av connectordesign och produktionshistorik. Yttriumoxidstabiliserad zirkoniumdioxid (Y-TZP) används frekvent inom tandvården. Helkeramiska broar måste dimensioneras och designas med hänsyn till bromaterialets specifika materialegenskaper. Särskilt kritisk är utformningen av connectorområdet. Rekommendationerna avseende connectordimensionerna för anteriora 3-4 ledsbroar av Y-TZP varierar mellan 2 till 4 mm i vertikal riktning och mellan 2 till 4 mm i horisontell riktning. Utöver dimensioneringen måste hänsyn tas till connectorns utformning då connectorns gingivala radie har en stor betydelse för konstruktionens totala brotthållfasthet. Vid belastning utsätts broar med liten gingival radie för högre spänningskoncentrationer i connectorområdet jämfört med broar med större gingival radie. Den gingivala utformningen av connectorer kan ha en ännu större betydelse för brotthållfastheten om antalet hängande led utökas från ett till två. Syftet med föreliggande studie var att undersöka hur förinställningarna avseende design av connectorer i två olika CAD/CAM system påverkar brotthållfastheten, hur den gingivala radiens storlek påverkar brotthållfasthet och frakturmönster samt undersöka hur brospannets längd, dvs antalet hängande led påverkar brotthållfastheten hos 3- och 4-ledsbroar av Y-TZP. Två olika CAD/CAM system användes för att framställa totalt 32 broskelett av Y-TZP, varav 16 st 3-ledsbroar med ett hängande led och 16 st 4-ledsbroar med två hängande led. Broskeletten delades in i 4 grupper baserat på antal led och utformning av connectorernas gingivala radie. För framställa grupperna 3Z:1, 4Z:1 användes en mekanisk scanner, Procera®Forte och för grupperna 3Z:2, 4Z:2 användes en optisk scanner, NobelProcera® Scanner. Samtliga broar utsattes för värmebehandling (simulerad porslinspåbränning), termocykling (5°C – 55°C / 5000 cykler), cyklisk förbelastning (30 – 300N / 10 000 cykler) och belastades slutligen till brott. Samtliga broar fakturerade i connectorområdet och efter okulär besiktning kunde man konstatera att samtliga frakturer startat i connectorns gingivala del. Medelvärdena för last vid brott var i grupp 3Z:1 734 N, grupp 4Z:1 405 N, grupp 3Z:2 910 N samt i grupp 4Z:2 520 N. Med reservation för de begränsningar som en In-vitro studie innebär dras följande Slutsatser: Förinställningarna i de olika CAD/CAM systemen hade avgörande betydelse för brotthållfastheten. Eftersom connectorområdet utgör den svagaste punkten i en helkeramisk brokonstruktion är det avgörande att CAD/CAM systemens standardinställningar tillåter en konstruktionsdesign som uppfyller de mekaniska och kliniska kraven. Storleken på den gingivala connectorradien har avgörande betydelse både för brotthållfastheten och för frakturmönster. Genom att öka antalet hängande led från ett till två hängande led minskar brokonstruktionens brotthållfasthet med ca 50 %.

Abstract [en]

Aims: To investigate how different default settings for connector design of two different CAD/CAM systems, i.e. to compare how different radii of curvature in the embrasure area of the connector affect the fracture strength and the fracture mode of 3-unit and 4-unit all-ceramic FDPs made from Y-TZP and to investigate how the number of pontics affect the fracture strength of Y-TZP. Material and methods: 32 all-ceramic three (3Z) and four (4Z) -unit, Y-TZP, FDP cores were made and divided in 4 groups, with 8 FDP in each group. The groups 3Z:1 and 4Z:1 were generated with a mechanical scanner, Procera® Forte and the FDPs in group 3Z:2 and 4Z:2 were generated with an optical scanner, NobelProcera® Scanner. The connector dimensions were set to 3 mm x 3 mm and core was set to 0.7 mm. The design of radius of the gingival and occlusal embrasures in the connector areas was set according to default settings and the manufacturer’s recommendations. All the FDP cores were subjected to heat treatment, thermocycled for 5,000 cycles, preloaded for 10,000 cycles to simulate ageing and finally loaded to fracture. Results: Regarding connector design a significant difference was found between group 3Z:1 and 3Z:2 (P<0.05), and group 4Z:1 (50% of the FDPs fractured during preloading 30-300N) and 4Z:2 (P<0.05). An extra pontic decreased the fracture strength up to 45%. Conclusions: The default settings of the two different CAD/CAM systems had a great impact on the fracture strength. It is important that a CAD/CAM system is equipped with possibilities to design a connector that fulfils the clinical demands of mechanical function and longevity. The most crucial factor for the load-bearing capacity is the design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice.

Place, publisher, year, edition, pages
Swedish dental association, 2013
Keywords
All-ceramic FDPs, connector-design, CAD/CAM, radii, 3-4 unit FDPs
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-6775 (URN)000331341000003 ()24620508 (PubMedID)2-s2.0-84894181650 (Scopus ID)17102 (Local ID)17102 (Archive number)17102 (OAI)
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2025-10-09Bibliographically approved
4. Influence of core design, production technique, and material selection on fracture behavior of yttria-stabilized tetragonal zirconia polycrystal fixed dental prostheses produced using different multilayer techniques: split-file, over-pressing, and manually built-up veneers
Open this publication in new window or tab >>Influence of core design, production technique, and material selection on fracture behavior of yttria-stabilized tetragonal zirconia polycrystal fixed dental prostheses produced using different multilayer techniques: split-file, over-pressing, and manually built-up veneers
2016 (English)In: Clinical, Cosmetic and Investigational Dentistry, E-ISSN 1179-1357, Vol. 8, p. 15-27Article in journal (Refereed) Published
Abstract [en]

Aim: To investigate and compare the fracture strength and fracture mode in eleven groups of currently, the most commonly used multilayer three-unit all-ceramic yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) fixed dental prostheses (FDPs) with respect to the choice of core material, veneering material area, manufacturing technique, design of connectors, and radii of curvature of FDP cores. Materials and methods: A total of 110 three-unit Y-TZP FDP cores with one intermediate pontic were made. The FDP cores in groups 1–7 were made with a split-file design, veneered with manually built-up porcelain, computer-aided design-on veneers, and over-pressed veneers. Groups 8–11 consisted of FDPs with a state-of-the-art design, veneered with manually built-up porcelain. All the FDP cores were subjected to simulated aging and finally loaded to fracture. Results: There was a significant difference (P<0.05) between the core designs, but not between the different types of Y-TZP materials. The split-file designs with VITABLOCS® (1,806±165 N) and e.max® ZirPress (1,854±115 N) and the state-of-the-art design with VITA VM® 9 (1,849±150 N) demonstrated the highest mean fracture values. Conclusion: The shape of a split-file designed all-ceramic reconstruction calls for a different dimension protocol, compared to traditionally shaped ones, as the split-file design leads to sharp approximal indentations acting as fractural impressions, thus decreasing the overall strength. The design of a framework is a crucial factor for the load bearing capacity of an all-ceramic FDP. The state-of-the-art design is preferable since the split-file designed cores call for a cross-sectional connector area at least 42% larger, to have the same load bearing capacity as the state-of-the-art designed cores. All veneering materials and techniques tested in the study, split-file, over-press, built-up porcelains, and glass–ceramics are, with a great safety margin, sufficient for clinical use both anteriorly and posteriorly. Analysis of the fracture pattern shows differences between the milled veneers and over-pressed or built-up veneers, where the milled ones show numerically more veneer cracks and the other groups only show complete connector fractures.

Place, publisher, year, edition, pages
Nakladatelstvi Lidove noviny, 2016
Keywords
all-ceramic FDPs, connector design radius, state-of-the-art, CAD/CAM, multilayer technique, veneering ceramic techniques
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-5660 (URN)10.2147/CCIDE.S94343 (DOI)000381874700002 ()26929667 (PubMedID)2-s2.0-84959348850 (Scopus ID)20493 (Local ID)20493 (Archive number)20493 (OAI)
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2026-05-27Bibliographically approved

Open Access in DiVA

Comprehensive summary(7823 kB)847 downloads
File information
File name FULLTEXT01.pdfFile size 7823 kBChecksum SHA-512
63db70db1ab356ce26b71926f0df51c99cbce1b5bc786d9690dab607a941027ebc8f333e32ef6e3de570d6da15510e301beb2dc85dcf7ee77b507213abe5c5bf
Type fulltextMimetype application/pdf
Order online >>

Authority records

Mahmood Jallal Hadi, Deyar

Search in DiVA

By author/editor
Mahmood Jallal Hadi, Deyar
By organisation
Faculty of Odontology (OD)
Dentistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 852 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1307 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf