Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history.
Malmö högskola, Faculty of Odontology (OD).ORCID iD: 0000-0002-9387-5222
Malmö högskola, Faculty of Odontology (OD).
Malmö högskola, Faculty of Odontology (OD).ORCID iD: 0000-0001-6593-0151
Malmö högskola, Faculty of Odontology (OD).ORCID iD: 0000-0003-2957-1133
2013 (English)In: Swedish Dental Journal, ISSN 0347-9994, Vol. 37, no 4, p. 179-187Article in journal (Refereed) Published
Abstract [sv]

Brotthållfasthet hos helkeramiska (Y-TZP) tre och fyra-leds broskelett: betydelsen av connectordesign och produktionshistorik. Yttriumoxidstabiliserad zirkoniumdioxid (Y-TZP) används frekvent inom tandvården. Helkeramiska broar måste dimensioneras och designas med hänsyn till bromaterialets specifika materialegenskaper. Särskilt kritisk är utformningen av connectorområdet. Rekommendationerna avseende connectordimensionerna för anteriora 3-4 ledsbroar av Y-TZP varierar mellan 2 till 4 mm i vertikal riktning och mellan 2 till 4 mm i horisontell riktning. Utöver dimensioneringen måste hänsyn tas till connectorns utformning då connectorns gingivala radie har en stor betydelse för konstruktionens totala brotthållfasthet. Vid belastning utsätts broar med liten gingival radie för högre spänningskoncentrationer i connectorområdet jämfört med broar med större gingival radie. Den gingivala utformningen av connectorer kan ha en ännu större betydelse för brotthållfastheten om antalet hängande led utökas från ett till två. Syftet med föreliggande studie var att undersöka hur förinställningarna avseende design av connectorer i två olika CAD/CAM system påverkar brotthållfastheten, hur den gingivala radiens storlek påverkar brotthållfasthet och frakturmönster samt undersöka hur brospannets längd, dvs antalet hängande led påverkar brotthållfastheten hos 3- och 4-ledsbroar av Y-TZP. Två olika CAD/CAM system användes för att framställa totalt 32 broskelett av Y-TZP, varav 16 st 3-ledsbroar med ett hängande led och 16 st 4-ledsbroar med två hängande led. Broskeletten delades in i 4 grupper baserat på antal led och utformning av connectorernas gingivala radie. För framställa grupperna 3Z:1, 4Z:1 användes en mekanisk scanner, Procera®Forte och för grupperna 3Z:2, 4Z:2 användes en optisk scanner, NobelProcera® Scanner. Samtliga broar utsattes för värmebehandling (simulerad porslinspåbränning), termocykling (5°C – 55°C / 5000 cykler), cyklisk förbelastning (30 – 300N / 10 000 cykler) och belastades slutligen till brott. Samtliga broar fakturerade i connectorområdet och efter okulär besiktning kunde man konstatera att samtliga frakturer startat i connectorns gingivala del. Medelvärdena för last vid brott var i grupp 3Z:1 734 N, grupp 4Z:1 405 N, grupp 3Z:2 910 N samt i grupp 4Z:2 520 N. Med reservation för de begränsningar som en In-vitro studie innebär dras följande Slutsatser: Förinställningarna i de olika CAD/CAM systemen hade avgörande betydelse för brotthållfastheten. Eftersom connectorområdet utgör den svagaste punkten i en helkeramisk brokonstruktion är det avgörande att CAD/CAM systemens standardinställningar tillåter en konstruktionsdesign som uppfyller de mekaniska och kliniska kraven. Storleken på den gingivala connectorradien har avgörande betydelse både för brotthållfastheten och för frakturmönster. Genom att öka antalet hängande led från ett till två hängande led minskar brokonstruktionens brotthållfasthet med ca 50 %.

Abstract [en]

Aims: To investigate how different default settings for connector design of two different CAD/CAM systems, i.e. to compare how different radii of curvature in the embrasure area of the connector affect the fracture strength and the fracture mode of 3-unit and 4-unit all-ceramic FDPs made from Y-TZP and to investigate how the number of pontics affect the fracture strength of Y-TZP. Material and methods: 32 all-ceramic three (3Z) and four (4Z) -unit, Y-TZP, FDP cores were made and divided in 4 groups, with 8 FDP in each group. The groups 3Z:1 and 4Z:1 were generated with a mechanical scanner, Procera® Forte and the FDPs in group 3Z:2 and 4Z:2 were generated with an optical scanner, NobelProcera® Scanner. The connector dimensions were set to 3 mm x 3 mm and core was set to 0.7 mm. The design of radius of the gingival and occlusal embrasures in the connector areas was set according to default settings and the manufacturer’s recommendations. All the FDP cores were subjected to heat treatment, thermocycled for 5,000 cycles, preloaded for 10,000 cycles to simulate ageing and finally loaded to fracture. Results: Regarding connector design a significant difference was found between group 3Z:1 and 3Z:2 (P<0.05), and group 4Z:1 (50% of the FDPs fractured during preloading 30-300N) and 4Z:2 (P<0.05). An extra pontic decreased the fracture strength up to 45%. Conclusions: The default settings of the two different CAD/CAM systems had a great impact on the fracture strength. It is important that a CAD/CAM system is equipped with possibilities to design a connector that fulfils the clinical demands of mechanical function and longevity. The most crucial factor for the load-bearing capacity is the design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice.

Place, publisher, year, edition, pages
Swedish dental association , 2013. Vol. 37, no 4, p. 179-187
Keywords [en]
All-ceramic FDPs, connector-design, CAD/CAM, radii, 3-4 unit FDPs
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-6775ISI: 000331341000003PubMedID: 24620508Scopus ID: 2-s2.0-84894181650Local ID: 17102OAI: oai:DiVA.org:mau-6775DiVA, id: diva2:1403726
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2025-10-09Bibliographically approved
In thesis
1. On core and bi-layered all-ceramic fixed dental prostheses, design and mechanical properties: studies on stabilized zirconiumdioxide
Open this publication in new window or tab >>On core and bi-layered all-ceramic fixed dental prostheses, design and mechanical properties: studies on stabilized zirconiumdioxide
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Loss of teeth can affect a person’s self-esteem, social life, appearance and oral function. Reconstruction of a missing tooth has scientifically been shown to increase self-esteem and quality of life and to maintain oral function. For many patients a fixed dental prostheses (FDP) is preferred, either tooth- or implant-supported. Improvement and development of all-ceramic materials have made them preferable to other alternatives. However, despite properties of dental ceramics’ well known biocompatibility, good chemical and mechanical, the materials have their weaknesses, such as brittleness and some difficulties with the layering porcelain. Many all-ceramic materials cannot withstand minor flexure; more than 0.1 - 0.3 %, will lead to fracture. Oxide-ceramic, specifically yttria stabilized tetragonal zirconia polycrystals (Y-TZP) has become the most commonly used all-ceramic material. This material has the potential to be used for larger restorations. In addition, one of many challenges is to ensure durable zirconia-based restorations in the oral cavity. In the clinical situation, crowns and bridges are supported by a combination of different structures with differing properties, i.e. bone, dentine and enamel. The complexity of the supporting tissues in the oral cavity creates stress patterns in the prosthetic material, which need to be considered when designing a dental restoration. The durability of all-ceramic FDPs is dependent on knowledge of the material and design of the FDPs. In particular the design, shape of the connector and the radius of curvature at the gingival embrasure play a significant role in the load-bearing capacity of FDPs. The overall aim of this thesis is to evaluate design of zirconia-based restorations in relation to achieving increased fracture resistance. Another aim is related to how the choice of material used for supporting tooth analogues in the test set-up and how this influences test results relating to fracture strength of all-ceramic FDPs. Study I evaluates different radii (0.60 and 0.90 mm) of curvature in the embrasure of the connector area and different connector dimensions (2 x 2, 3 x 2 and 3 x 3 mm) and their effects on the fracture resistance of 3-unit all-ceramic FPDs made of Y-TZP. The results show that by increasing the radius of the gingival embrasure from 0.6 to 0.9 mm, the fracture strength for a Y-TZP FPD with connector dimension 3 x 3 mm will increase by 20%. Study II investigated how the choice of material (aluminium, polymer and DuraLay) used for supporting tooth analogues and support complexity influence test results concerning the fracture strength of FDPs made of a brittle material Y-TZP. The outcome of the study demonstrated that Y-TZP FDPs cemented on tooth analogues made of aluminium, with high E-modulus showed a significantly higher load at fracture and a different fracture mode than shown in clinical situations. Study III evaluates how factors as different default settings for connector design of two different CAD/CAM systems and different radii of curvature in the embrasure area of the connector will affect the fracture strength and the fracture mode of 3-unit, i.e. 4-unit allceramic FDPs made from Y-TZP and further to investigate how the number of pontics affect the fracture strength of Y-TZP. The results showed that the most crucial factor for the load-bearing capacity is the design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice. Study IV investigate and compare the fracture strength and fracture mode in 11 groups of the currently most used multilayer all-ceramic systems for Y-TZP FDPs, with respect to the choice of core material, veneering material area, manufacturing technique (split-file, overpress, built-up porcelains and glass-ceramics), design of connectors and radius of curvature of FDP cores. The results show that the design of a framework is a crucial factor for the load bearing capacity of an all-ceramic FDP. The state-of-the-art designs are preferable, since the split-file designed cores call for a cross-sectional connector area, at least 42% larger, to have the same load bearing capacity as the state-of-the-art designed cores. Analyses of the fracture patterns demonstrated differences between the milled veneers and over-pressed or built-up veneers, where the milled ones showed numerically more veneer cracks whereas the other groups only showed complete connector fractures. All veneering materials/techniques tested were found, with great safety margin to be sufficient for clinical use both anteriorly and posteriorly.

Place, publisher, year, edition, pages
Malmö University, Faculty of Odontology, 2015. p. 102
Series
Doctoral Dissertation in Odontology
Keywords
Y-TZP, Zirconia, All-ceramic FDPs, connector design, radius, state-of-the-art, CAD/CAM, multi-layer technique, veneering ceramic, split-file, over-pressing, dental porcelain, MECHANICAL PROPERTIES
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-7703 (URN)18473 (Local ID)9789171044051 (ISBN)9789171044068 (ISBN)18473 (Archive number)18473 (OAI)
Note

Note: The papers are not included in the fulltext online.

Paper IV in dissertation as manuscript.

Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2025-01-08Bibliographically approved

Open Access in DiVA

fulltext(313 kB)91 downloads
File information
File name FULLTEXT01.pdfFile size 313 kBChecksum SHA-512
08a37e7bb4d2c1c39d3741acbb91fb87aa0bc870a177e50b461e143c5676401cc13db21214dea8b03a1470ee63d17a178717579199a71ba8d51f460c6695e532
Type fulltextMimetype application/pdf

PubMedScopus

Authority records

Mahmood Jallal Hadi, DeyarLinderoth, Ewa HVult von Steyern, PerWennerberg, Ann

Search in DiVA

By author/editor
Mahmood Jallal Hadi, DeyarLinderoth, Ewa HVult von Steyern, PerWennerberg, Ann
By organisation
Faculty of Odontology (OD)
In the same journal
Swedish Dental Journal
Dentistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 94 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

pubmed
urn-nbn

Altmetric score

pubmed
urn-nbn
Total: 209 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf