Oscillometry in Chronic Obstructive Lung Disease: In vitro and in vivo evaluation of the impulse oscillometry and tremoflo devices
Meakins-Christie Laboratories, McGill University, Montréal, QC, Canada; Thorasys Thoracic Medical Equipment Inc., Montréal, QC, Canada.
Malmö universitet, Fakulteten för hälsa och samhälle (HS), Institutionen för biomedicinsk vetenskap (BMV).
Department of Respiratory Medicine and Allergology, Lund University, Malmö, Sweden.
Department of Translational Medicine, Lund University, Malmö, Sweden.
2019 (Engelska)Ingår i: Scientific Reports, E-ISSN 2045-2322, Vol. 9, nr 1, artikel-id 11618Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Impedance, or oscillometry, measurements of the respiratory system can generate information about the function of the respiratory system not possible with traditional spirometry. There are currently several instruments on the market using different perturbations. We have compared a new respiratory oscillometry instrument, the tremoflo, with Impulse Oscillometry (IOS). Patients with a physician's diagnosis of chronic obstructive lung disease (COPD) and healthy subjects were recruited. They underwent assessment of respiratory function with oscillometry using the IOS and tremoflo devices and the resulting impedance data from the two methods were compared. The two devices were also tested against a reference respiratory phantom with variable resistances. Whereas both devices detected impairments in the patients' lung function commensurate with small airways pathology, the tremoflo appeared to be more sensitive than the IOS. We found systematic differences between the two instruments especially for reactance measurements where the area over the reactance curve (AX) was significantly lower with the IOS compared with the tremoflo (p < 0.001). Moreover, the agreement between the two devices was reduced with increasing severity of the disease as determined with a Bland-Altman test. Testing both instruments against a respiratory phantom unit confirmed that the resistance measured by the tremoflo compares closely with the known resistance of test loads, whereas the IOS'resistance correlated with a test load of 0.19, kPa.s.L-1 at higher loads it deviated significantly from the known resistance (p < 0.0028). We conclude that the absolute values measured with the two devices may not be directly comparable and suggest that differences in the calibration procedures might account for the differences.

Ort, förlag, år, upplaga, sidor
Nature Publishing Group, 2019. Vol. 9, nr 1, artikel-id 11618
Nyckelord [en]
Multidisciplinary Sciences
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:mau:diva-4568DOI: 10.1038/s41598-019-48039-xISI: 000480385200011PubMedID: 31406190Scopus ID: 2-s2.0-85070589149Lokalt ID: 30215OAI: oai:DiVA.org:mau-4568DiVA, id: diva2:1401400
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2024-06-17Bibliografiskt granskad

Open Access i DiVA

fulltext(1158 kB)140 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1158 kBChecksumma SHA-512
0a6fc218f350e99095f3ec4b49222922bbc662eb68463d2f5041e59a92d898a144bf301c553e4b6e3a771fd452a93b221df97c1d549e387c8fdf70d912f838f9
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Miletic, Ruzica

Sök vidare i DiVA

Av författaren/redaktören
Miletic, Ruzica
Av organisationen
Institutionen för biomedicinsk vetenskap (BMV)
I samma tidskrift
Scientific Reports
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 140 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 61 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf