Publikationer från Malmö universitet
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Factors Affecting the Efficacy of Airflowing in Cleaning Implant Surfaces in a Surgical Peri-Implantitis Treatment Simulation: A Laboratory Study
Malmö universitet, Odontologiska fakulteten (OD). Blekinge Hospital, Karlskrona, Sweden; Division of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria; Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.ORCID-id: 0000-0001-8161-3754
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Midwifery Research and Education Unit, Hannover Medical School, Hannover, Germany.ORCID-id: 0000-0001-9515-582X
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 36, nr 9, s. 1146-1158Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: To evaluate, in a simulation of surgical peri-implantitis treatment, the impact of type of handpiece, device settings, and instrumentation time on the efficacy of airflowing in cleaning the implant surface, depending on the type of bone defect and implant surface. Methods: Turned and modified surface implants (54 each) were coated with biofilm imitation and mounted on resin models replicating purely horizontal or circumferential intraosseous peri-implant defects (both 5 mm deep). Implants were instrumented with an airflowing device using a supra- or submucosal handpiece, with three settings: (a) power 5, 5 s (b) power 10, 5 s, and (c) power 5, 15 s per implant/defect sextant. Results: The amount of residual biofilm imitation was associated with defect configuration, type of handpiece, and device settings (p < 0.15); implant surface did not have an effect. In horizontal defects, with the supramucosal handpiece, only 3 of 54 implants showed > 5% residual biofilm imitation and 23 of 54 implants were completely clean; with the submucosal handpiece, 12 of 18 implants showed ≤ 5% residual biofilm imitation when used for 15 s/sextant, yet none were completely clean. In intraosseous defects, all implants presented ≤ 5% residual biofilm imitation and 10 of 18 implants were completely clean with the submucosal handpiece used for 15 s/sextant; the supramucosal handpiece was largely inefficacious. Conclusion: Within the limitations of this laboratory study, peri-implant bone defect configuration should dictate the choice of airflowing handpiece (i.e., for horizontal defects, the supramucosal handpiece; for intraosseous defects, the submucosal handpiece) and intrasurgical airflowing requires a prolonged instrumentation time, but not increased power.

Ort, förlag, år, upplaga, sidor
John Wiley and Sons Inc , 2025. Vol. 36, nr 9, s. 1146-1158
Nyckelord [en]
airflowing, decontamination, dental implants, implant surface, peri-implantitis
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-78796DOI: 10.1111/clr.14464ISI: 001513050700001PubMedID: 40545767Scopus ID: 2-s2.0-105008762710OAI: oai:DiVA.org:mau-78796DiVA, id: diva2:1988196
Tillgänglig från: 2025-08-11 Skapad: 2025-08-11 Senast uppdaterad: 2025-10-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Stavropoulos, AndreasBertl, Kristina

Sök vidare i DiVA

Av författaren/redaktören
Stavropoulos, AndreasSpineli, Loukia M.Heimel, PatrickBertl, Kristina
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Clinical Oral Implants Research
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 48 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf