Publikationer från Malmö universitet
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Titanium- and zirconia-based implant-supported fixed dental prostheses: A randomized, prospective clinical pilot trial
Malmö högskola, Odontologiska fakulteten (OD).ORCID-id: 0000-0001-6593-0151
Malmö högskola, Odontologiska fakulteten (OD).ORCID-id: 0000-0002-3912-0830
2014 (Engelska)Ingår i: Swedish Dental Journal, ISSN 0347-9994, Vol. 38, nr 1, s. 23-30Artikel i tidskrift (Refereegranskat) Published
Abstract [sv]

Målsättningen med studien var att jämföra implantat-stödda partiella broar av titan-porslin respektive yttria-stabiliserad zirkoniumdioxid med ytporslin. Sexton patienter fick sammanlagt 18 broar; 8 av titan-porslin och 10 av yttria-stabiliserad zirkoniumdioxid-porslin. Broarna fördelades randomiserat till respektive material-grupp. Patienterna följdes upp och kontrollerades en första gång efter 3 månader och därefter en gång per år. Ett bedömningsprotokoll baserat på California Dental Association (CDA) kriterier användes. Alla patienter genomförde kontrollbesöken. Genomsnittlig uppföljningstid var 15,2 månader (12-24 månader). Alla konstruktioner var i funktion vid uppföljning och alla patienter var nöjda med behandlingen. Inga tekniska komplikationer noterades i någon av grupperna. Biologiska komplikationer av ringa betydelse, plack och/eller mucosit, som inte påverkade konstruktionernas överlevnad noterades vid 6 av titan-keramik broarna och 2 av zirkonia-porslins broarna. Skillnaden var inte statistiskt signifikant. Sammanfattningsvis kan vi i denna studie konstatera att båda materialen fungerade jämförbart. Data från denna studie antyder att implantat-stödda partiella broar av titan-porslin respektive zirkoniumdioxid med ytporslin uppvisar goda resultat över kort sikt. Studier med fler patienter och längre uppföljningstid rekommenderas emellertid innan definitiva slutsatser kan dras.

Abstract [en]

The aim of this study was to compare porcelain-veneered implant-supported FDPs based on zirconium dioxide and titanium respectively. Sixteen patients received 18 implant-supported partial fixed dental prostheses (FDPs); 8 titanium-based and 10 zirconia-based. The FDPs were randomized between the two material groups. Follow-up of the patients was performed at 3 months and thereafter once a year. An assessment protocol based on the California Dental Association (CDA) quality assessment system was used. Results: All patients were seen at follow-up. The mean time of clinical service at follow-up was 15,2 months (range 12-24 months). All restorations were in place and all patients were satisfied with the treatment. No technical complications were noted in either group. Minor biological complications, in the form of plaque and/or mucositis, not affecting the survival of the restorations were noted for six of the titanium-based restorations and two of the zirconia-based restorations. The difference between the two material groups was not statistically significant. The outcomes of both materials were comparable. Short term data from this study suggests that porcelain-veneered implant-supported partial FDPs based on zirconia and titanium are satisfactory and equal treatment options. This conclusion is however preliminary as it is based on a small number of patients and short-term follow-up. Long-term follow-up of larger groups of patients is needed before more definite conclusions can be made.

Ort, förlag, år, upplaga, sidor
Swedish dental association , 2014. Vol. 38, nr 1, s. 23-30
Nyckelord [en]
titanium, yttria stabilized tetragonal zirconia, porcelain veneer, dental implants, fixed dental prostheses
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-15626ISI: 000333727300003PubMedID: 26995808Scopus ID: 2-s2.0-84898743122Lokalt ID: 18689OAI: oai:DiVA.org:mau-15626DiVA, id: diva2:1419148
Tillgänglig från: 2020-03-30 Skapad: 2020-03-30 Senast uppdaterad: 2024-08-29Bibliografiskt granskad

Open Access i DiVA

fulltext(241 kB)120 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 241 kBChecksumma SHA-512
1c413034d9ba772592018f9944279f680136023e0bfdff145b8c9c551ce0df550fde1500089a2635b6ca7f74e323f5f18d9b3176a3518232da219f104ab613ce
Typ fulltextMimetyp application/pdf

PubMedScopus

Person

Vult von Steyern, PerLarsson, Christel

Sök vidare i DiVA

Av författaren/redaktören
Vult von Steyern, PerLarsson, Christel
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Swedish Dental Journal
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 122 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

pubmed
urn-nbn

Altmetricpoäng

pubmed
urn-nbn
Totalt: 201 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf