Publikationer från Malmö universitet
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effects of titanium surface topography on bone integration
Malmö högskola, Odontologiska fakulteten (OD).ORCID-id: 0000-0003-2957-1133
Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID-id: 0000-0001-5719-0157
2009 (Engelska)Ingår i: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 20, nr Supplement 4, s. 172-184Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Aim: To analyse possible effects of titanium surface topography on bone integration. Materials and methods: Our analyses were centred on a PubMed search that identified 1184 publications of assumed relevance; of those, 1064 had to be disregarded because they did not accurately present in vivo data on bone response to surface topography. The remaining 120 papers were read and analysed, after removal of an additional 20 papers that mainly dealt with CaP-coated and Zr implants; 100 papers remained and formed the basis for this paper. The bone response to differently configurated surfaces was mainly evaluated by histomorphometry (bone-to-implant contact), removal torque and pushout/pullout tests. Results and discussion: A huge number of the experimental investigations have demonstrated that the bone response was influenced by the implant surface topography; smooth (Sa<0.5 μm) and minimally rough (Sa 0.5–1 μm) surfaces showed less strong bone responses than rougher surfaces. Moderately rough (Sa>1–2 μm) surfaces showed stronger bone responses than rough (Sa>2 μm) in some studies. One limitation was that it was difficult to compare many studies because of the varying quality of surface evaluations; a surface termed 'rough' in one study was not uncommonly referred to as 'smooth' in another; many investigators falsely assumed that surface preparation per se identified the roughness of the implant; and many other studies used only qualitative techniques such as SEM. Furthermore, filtering techniques differed or only height parameters (Sa, Ra) were reported. Conclusions: • Surface topography influences bone response at the micrometre level. • Some indications exist that surface topography influences bone response at the nanometre level. • The majority of published papers present an inadequate surface characterization. • Measurement and evaluation techniques need to be standardized. • Not only height descriptive parameters but also spatial and hybrid ones should be used.

Ort, förlag, år, upplaga, sidor
2009. Vol. 20, nr Supplement 4, s. 172-184
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-7118DOI: 10.1111/j.1600-0501.2009.01775.xISI: 000268296200017PubMedID: 19663964Scopus ID: 2-s2.0-68549092607Lokalt ID: 9014OAI: oai:DiVA.org:mau-7118DiVA, id: diva2:1404072
Konferens
European Association for Osseointegration; 2nd Consensus Conference, Pfaffikon, Switzerland (19-22 February 2009)
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2025-10-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Wennerberg, AnnAlbrektsson, Tomas

Sök vidare i DiVA

Av författaren/redaktören
Wennerberg, AnnAlbrektsson, Tomas
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Clinical Oral Implants Research
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 47 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf