Publikationer från Malmö universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Validation Study of the Impression Replica Technique.
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Journal of Prosthodontics, ISSN 1059-941X, E-ISSN 1532-849X, Vol. 28, nr 2, s. e609-e616Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. MATERIALS AND METHODS: The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. RESULTS: The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 mum. CONCLUSION: The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry.

Ort, förlag, år, upplaga, sidor
John Wiley & Sons, 2019. Vol. 28, nr 2, s. e609-e616
Nyckelord [en]
Internal gap, marginal gap, misfit, production tolerance
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-6937DOI: 10.1111/jopr.12795ISI: 000458904300043PubMedID: 29664193Scopus ID: 2-s2.0-85045757643Lokalt ID: 26706OAI: oai:DiVA.org:mau-6937DiVA, id: diva2:1403891
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2024-02-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Braian, MichaelAmeri, ArmanAhlgren, Camilla

Sök vidare i DiVA

Av författaren/redaktören
Braian, MichaelAmeri, ArmanAhlgren, Camilla
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Journal of Prosthodontics
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 195 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf