Publikationer från Malmö universitet
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effects on blood pressure after treatment of obstructive sleep apnoea with a mandibular advancement appliance - a three-year follow-up
Malmö högskola, Odontologiska fakulteten (OD).ORCID-id: 0000-0002-2812-5409
2009 (Engelska)Ingår i: Journal of Oral Rehabilitation, E-ISSN 1365-2842, Vol. 36, s. 719-725Artikel i tidskrift (Refereegranskat)
Abstract [en]

Obstructive sleep apnoea (OSA) is a highly prevalent sleep disorder; it affects 4% of males and 2% of females. Hypertension has been shown to occur in 28-57% of OSA patients. There is a steady increase in evidence linking OSA to long-term cardiovascular morbidity including hypertension. The purpose of this study was to investigate whether mandibular advancement oral appliance (OA) treatment of OSA affects the patient's blood pressure (BP) in a 3-month and a 3-year perspective. Twenty-nine consecutive patients, with verified OSA defined as apnoea index (AI) >5 per hour and/or apnoea/hypopnoea index (AHI) > or =10 per hour, received an OA as treatment. BP was measured on three occasions; before treatment, after 3 months of treatment, and after 3 years of treatment. BP was measured with an electronic blood pressure monitor. The treatment effect of OA was measured after 3 months by repeated somnographic registration while the patient was wearing the OA. A treatment response was defined as AHI < 10; this was achieved in 25 of 29 patients (86%) at the 3-month evaluation. Significant reductions in blood pressure were attained between baseline and the 3-month evaluation (P < 0.001) and these changes remained at the 3-year follow-up in both systolic BP of -15.4 +/- 18.7 mm Hg and diastolic BP of -10.3 +/- 10.0 mm Hg. OA therapy reduced blood pressure in both a 3-month and a 3-year perspective in patients with OSA.

Ort, förlag, år, upplaga, sidor
2009. Vol. 36, s. 719-725
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-6770DOI: 10.1111/j.1365-2842.2009.01987.xISI: 000269730600003PubMedID: 19678869Scopus ID: 2-s2.0-70349092204Lokalt ID: 9121OAI: oai:DiVA.org:mau-6770DiVA, id: diva2:1403721
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2024-02-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Tegelberg, Åke

Sök vidare i DiVA

Av författaren/redaktören
Tegelberg, Åke
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Journal of Oral Rehabilitation
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 98 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf