Publikationer från Malmö universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A comparative study on image quality of two digital intraoral sensors.
Section of Oral Diagnostics and Surgery, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden.
Malmö universitet, Odontologiska fakulteten (OD).ORCID-id: 0000-0001-9885-0019
Section of Oral Diagnostics and Surgery, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden; Section of Oral Maxillofacial Radiology, Department of Clinical Dentistry, University of Bergen, Bergen, Norway.
2019 (Engelska)Ingår i: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, E-ISSN 1476-542X, Vol. 48, nr 7, s. 1-5, artikel-id 20190063Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

OBJECTIVES: The aims of this study were to evaluate the subjective image quality and reliability of two digital sensors. In addition, the image quality of the two sensors evaluated by specialists and general dentists were compared. METHODS: 30 intraoral bitewings from five patients were included in the study, 15 were exposed with a Dixi sensor (CCD-based) and 15 with a ProSensor (CMOS-based) using modified parallel technique. Three radiologists and three general dentists evaluated the images in pair. A five-point scale was used to register the image quality. Visual grading characteristics (VGC) analysis was performed to compare the image quality and the observer agreement was assessed in terms of intra class correlation co-efficient. RESULTS: No statistically significant difference was found on image quality between the sensors. The average scores of the observer agreement were moderate with an average of 0.66 and an interval of 0.30 to 0.87, suggesting that there was a large variation on preference of image quality. However, there was a statistically significant difference in terms of the area under the VGC- curves between the specialist group and the general dentist group ( p = 0.043), in which the specialist group tended to favor the ProSensor. CONCLUSIONS: Subjective image quality of the two intraoral sensors were comparable when evaluated by both general and oral radiologists. However, the radiologists seemed to prefer the ProSensor to the Dixi as compared to general dentists. Inter- observer conformance showed a large variation on the preference of the image quality.

Ort, förlag, år, upplaga, sidor
British Institute of Radiology , 2019. Vol. 48, nr 7, s. 1-5, artikel-id 20190063
Nyckelord [en]
digital imaging, dental, digital sensors, image quality
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-6286DOI: 10.1259/dmfr.20190063ISI: 000487315700007PubMedID: 31075041Scopus ID: 2-s2.0-85072508934Lokalt ID: 30161OAI: oai:DiVA.org:mau-6286DiVA, id: diva2:1403227
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2024-06-17Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Hellén-Halme, Kristina

Sök vidare i DiVA

Av författaren/redaktören
Hellén-Halme, Kristina
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Dento-Maxillo-Facial Radiology
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 99 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf