Publikationer från Malmö universitet
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A within-implant comparison to evaluate the concept of platform switching: a randomised controlled trial
Malmö högskola, Odontologiska fakulteten (OD).
2012 (Engelska)Ingår i: European Journal of Oral Implantology, ISSN 1756-2406, E-ISSN 1756-2414, Vol. 5, nr 3, s. 253-262Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: To evaluate whether platform switching could preserve marginal bone around implants up to 6 months after loading. MATERIALS AND METHODS: 15 patients were selected for a randomised controlled trial. Each patient received one customised wide body implant, with the external hex connection located eccentrically, allowing an extra 1 mm switch on one side. The hex was positioned at random at the mesial or distal side and the implant was loaded after 6 months of non-submerged healing. Patients were examined at 3, 6 and 12 months after surgery, during which a radiograph was taken to evaluate bone levels. At 12 months, the mucosal thickness was measured using a perio-probe. RESULTS: All implants survived and the mean overall bone loss, calculated from both the switched and non-switched side, was 0.39 mm (SD 0.33, range 0.00-1.45), 0.85 mm (SD 0.59, range 0.10-2.50) and 0.80 mm (SD 0.46, 0.26-1.89) after 3, 6 and 12 months, respectively. The bone loss continued up to 6 months but stabilised thereafter (P = 0.615). Significantly more bone loss was observed at the non-switched side compared to the switched side at 3 months (0.51 mm versus 0.28 mm, P = 0.019), 6 months (1.05 mm versus 0.64 mm, P = 0.002) and 12 months (0.94 mm versus 0.66 mm, P = 0.002). The mean mucosal thickness was 4.22 mm (SD 1.45; range 1.50-7.00), and was not significantly different between the switched and non-switched sides (P = 0.882). However, using a post-hoc analysis with the mean thickness as a threshold, the mean bone loss was only significantly different between switched and non-switched sides when the mucosa was thicker than 4.22 mm (P = 0.036). CONCLUSIONS: The outcome of this randomised trial is in accordance with earlier studies suggesting that that platform switching decreases bone loss by 30%. Although the sample size was limited, it seems that the creation of a biologic width affects peri-implant bone loss to a significant extent and that platform switching is only effective when the mucosal thickness allows the establishment of a biologic width.

Ort, förlag, år, upplaga, sidor
Quintessence , 2012. Vol. 5, nr 3, s. 253-262
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-6196ISI: 000309897300004PubMedID: 23000709Scopus ID: 2-s2.0-84871707650Lokalt ID: 17534OAI: oai:DiVA.org:mau-6196DiVA, id: diva2:1403136
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2024-08-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

PubMedScopushttp://ejoi.quintessenz.de/index.php?doc=abstract&abstractID=28383/

Person

Vandeweghe, Stefan

Sök vidare i DiVA

Av författaren/redaktören
Vandeweghe, Stefan
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
European Journal of Oral Implantology
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetricpoäng

pubmed
urn-nbn
Totalt: 106 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf