Publikationer från Malmö universitet
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Zirconia dental implants: the influence of design on clinical outcomes, stress distribution and fracture resistance
Malmö universitet, Odontologiska fakulteten (OD).ORCID-id: 0000-0001-7726-7086
2026 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

In recent years, zirconia dental implants have been attracting increasingly more recognition and interest. Commercially, these implants are available in either one- piece (OPI) or two-piece (TPI) designs. The TPI design is categorised as either bone- level (BL) or tissue-level (TL) and is connected to the abutment with either a titanium or a ceramic abutment screw. Due to zirconia's brittle nature and high elastic modulus, the design of zirconia implants and their implant to abutment connection may influence load transfer from the prosthesis to the implant and surrounding bone, thereby affecting stress distribution, fracture resistance, and ultimately clinical survival.

Existing research on stress distribution, fracture resistance, and clinical outcomes of various zirconia implant designs and material combinations is limited. Therefore, this thesis aims to evaluate the clinical outcomes, stress concentrations, and fracture resistance of different designs of zirconia dental implants. In line with the aim, the thesis comprises three studies: Study I – A systematic review of clinical studies that evaluated the clinical outcomes of various zirconia implant designs. The findings showed that the one-piece implant had a promising 5-year clinical survival rate (95%), with no difference across implant diameters and lengths. The design with an acid-etched surface showed higher survival compared to other surfaces.

Study II – A finite element analysis that evaluated the location of high-stress levels and concentrations in various zirconia implant designs. The findings showed that OPI and TPI designs showed differing stress distributions. TPIs demonstrated lower stress within the implant body but higher stress transfer to the specimen holder. Among TPI designs, Implant level (TL vs BL) and abutment screw design/material influenced the stress distribution within the implant-abutment complex.

Study III – An in vitro laboratory study that evaluated the fracture resistance, fracture mode, and crystal phase change after dynamic preloading of various zirconia dental implant designs. The findings showed that the evaluated zirconia-based OPI, BLTPI, and TLTPI systems possessed adequate fracture resistance for further clinical evaluation. Fracture resistance and fracture mode were influenced by implant-level design (TL vs BL), whereas the abutment screw design/material (ceramic vs titanium) had a less pronounced influence and depended on the implant- level design.

Overall, within the limitations of this thesis, zirconia dental implants should not be regarded as a uniform category. Differences in implant design, including OPI and TPI, TL and BL configurations, and implant-abutment connection design, influence clinical outcomes, stress distribution, and fracture resistance. Clinical evidence is currently better established for OPI, which has shown promising clinical outcomes, while evidence for TPI remains limited. Mechanically, TL TPI shows the highest fracture resistance among the evaluated designs. However, further long-term clinical studies are needed to confirm these findings, particularly for TPI.

Abstract [sv]

På senare år har dentala implantat av zirkoniumdioxid fått ökad uppmärksamhet inom tandvården. Kommersiellt finns dessa implantat tillgängliga i olika designer, antingen som en del där implantat och distans utgör en enhet (one piece implant, OPI) eller i två delar (two piece implant, TPI) som bestående av implantat och distans.

TPI-designen delas i sin tur in, utifrån implantat–distanskopplingens position i förhållande till alveolarbenet, i ben- (bone level, BL) eller mjukvävnadsnivå (tissue level TL) och har en distansskruv av antingen titan eller keramik. Eftersom zirkonia är ett sprött material med hög elasticitetsmodul kan designen av zirkoniaimplantat och deras implantat–distanskoppling påverka belastningsöverföringen från den protetiska konstruktionen till implantatet och det omgivande benet, och därmed påverka spänningsfördelning, brotthållfasthet och i förlängningen kliniska resultat. Det finns dock begränsad forskning kring spänningsfördelning, brotthållfasthet och kliniska data för olika zirkoniabaserade designer av implantat och olika materialkombinationer.

Denna avhandling syftar till att utvärdera kliniska resultat, spänningskoncentrationer, brottshållfasthet och frakturmönster hos olika designer av dentala zirkoniabaserade implantat. I linje med avhandlingens övergripande syfte omfattar tre delstudier: Delarbete I var en systematisk översiktsstudie av kliniska studier som utvärderade kliniska resultat av olika designer av zirkoniabaserade implantat. Resultaten visade att implantat i en del (OPI) uppvisade en lovande klinisk överlevnadsgrad (95 %) efter fem år, utan några skillnader mellan olika implantatdiametrar och implantatlängder. Implantatdesignen med en syraetsad yta uppvisade högre klinisk överlevnad jämfört med implantat med andra ytor.

Delarbete II var en finit elementanalys (FEA) som utvärderade var höga spänningsnivåer och spänningskoncentrationer uppstod i olika designer av zirkoniabaserade implantatsystem. Resultaten visade att OPI- och TPI-designerna hade olika spänningsfördelningar. TPI-design uppvisade lägre spänning i det inre av själva implantatet men högre spänningsöverföring till provhållaren jämfört med OPI. I implantat-distans-komplexet uppvisade implantatutformning på mjukvävnadsnivå (TL) lägre spänning än på bennivå (BL), medan spänningarna i distansen var beroende av distansskruvens design och material. TPI med keramisk distansskruv uppvisade högre spänningsnivåer jämfört med distansskruv av titan. Delarbete III var en laboratoriestudie som utvärderade brotthållfasthet, frakturmönster och kristallfasomvandling efter dynamisk förbelastning av olika designer av zirkoniaimplantat. Resultaten visade att de utvärderade zirkoniabaserade implantatsystemen (OPI, BLTPI och TLTPI) uppvisade tillräcklig brotthållfasthet för att motivera vidare klinisk utvärdering. Designen av TPI (bennivå kontra mjukvävnadsnivå) påverkade brotthållfasthet och frakturmönster, medan distansskruvens utformning och material (keramik eller titan) hade en mindre uttalad inverkan som dessutom varierade beroende på implantatets design. Sammantaget, inom ramen för avhandlingens begränsningar, bör dentala implantat av zirkoniumdioxid inte betraktas som en enhetlig kategori. Skillnader i implantatdesign, inklusive OPI och TPI samt TL- och BL-konfigurationer och utformningen av implantat–distanskopplingen, påverkar kliniska resultat, spänningsfördelning och brotthållfasthet. Det kliniska underlaget är för närvarande bättre etablerat för OPI, som har visat lovande kliniska resultat, medan underlaget för TPI fortfarande är begränsat. Mekaniskt uppvisar TL TPI den högsta brotthållfastheten bland de utvärderade implantatdesignerna. Ytterligare långsiktiga kliniska studier behövs dock för att bekräfta dessa fynd, särskilt för TPI. 

Ort, förlag, år, upplaga, sidor
Malmö: Malmö University Press, 2026. , s. 139
Serie
Malmö University Odontological Dissertations, ISSN 1650-6065, E-ISSN 2004-9307
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:mau:diva-88322DOI: 10.24834/isbn.9789178777761ISBN: 978-91-7877-775-4 (tryckt)ISBN: 978-91-7877-776-1 (digital)OAI: oai:DiVA.org:mau-88322DiVA, id: diva2:2104210
Disputation
2026-10-23, Odontologiska fakulteten KL:2370 Aulan, Smedjegatan 16, Malmö, 09:15 (Engelska)
Handledare
Tillgänglig från: 2026-09-23 Skapad: 2026-09-23 Senast uppdaterad: 2026-10-27Bibliografiskt granskad
Delarbeten
1. Zirconia dental implants; the relationship between design and clinical outcome: A systematic review
Öppna denna publikation i ny flik eller fönster >>Zirconia dental implants; the relationship between design and clinical outcome: A systematic review
Visa övriga...
2024 (Engelska)Ingår i: Journal of Dentistry, ISSN 0300-5712, E-ISSN 1879-176X, Vol. 143, artikel-id 104903Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

OBJECTIVE: To evaluate the clinical outcome of different designs of zirconia dental implants.

DATA: This systematic review adhered to the PRISMA checklist and followed the PICO framework. The protocol is registered in PROSPERO (CRD42022337228).

SOURCES: The search was conducted in March 2023 through four databases (PubMed, Web of Science, Cochrane Library, and Google Scholar) along with a search of references in the related reviews. Three authors reviewed on title, and abstract level and analysed the risk of bias, and all authors reviewed on a full-text level.

STUDY SELECTION: Clinical studies excluding case reports for patients treated with different designs of zirconia dental implants were included. From a total of 2728 titles, 71 full-text studies were screened, and 27 studies were included to assess the risk of bias (ROBINS-I tool) and data extraction. After quality assessment, four studies were included, and the remaining 23 excluded studies were narratively described.

RESULT: The included prospective studies with moderate risk of bias reported success and survival rates of one-piece implants that ranged between 95 and 98.4 % with no difference between different lengths and diameters. The acid-etched roughened surface showed higher clinical outcomes compared to other surface roughness designs.

CONCLUSION: Promising 5-year clinical outcomes were found for one-piece zirconia implants with no difference between different diameters and lengths. Concerning surface roughness, better outcomes were found when using the acid-etched implant surface. However, due to the limited available studies, further high-quality clinical studies comparing zirconia one-piece and two-piece implants with different diameters, lengths, and surface roughness are needed.

CLINICAL SIGNIFICANCE: Based on this systematic review, under suitable clinical situations, the one-piece zirconia implants with diameters of 4.0 mm, 4.5 mm, or 5.5 mm and lengths of 8 mm, 10 mm, 12 mm, or 14 mm have similar promising clinical outcomes. Additionally, the acid-etched roughened implant surface may be preferable.

Ort, förlag, år, upplaga, sidor
Elsevier, 2024
Nyckelord
Ceramics, Clinical outcome, Dental implant, Implant design, Implant diameter, Implant surface
Nationell ämneskategori
Odontologi
Identifikatorer
urn:nbn:se:mau:diva-66564 (URN)10.1016/j.jdent.2024.104903 (DOI)001207555400001 ()38437977 (PubMedID)2-s2.0-85187316975 (Scopus ID)
Tillgänglig från: 2024-03-28 Skapad: 2024-03-28 Senast uppdaterad: 2026-09-23Bibliografiskt granskad
2. Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis
Öppna denna publikation i ny flik eller fönster >>Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis
Visa övriga...
2026 (Engelska)Ingår i: BMC Oral Health, E-ISSN 1472-6831, Vol. 26, nr 1, artikel-id 780Artikel i tidskrift (Refereegranskat) Published
Ort, förlag, år, upplaga, sidor
Springer Nature, 2026
Nyckelord
Bone-level, Ceramics, Dental implants, Finite element analysis, Implant design, One-piece implant, Screw material, Stress analysis, Tissue-level, Zirconia
Nationell ämneskategori
Odontologi
Identifikatorer
urn:nbn:se:mau:diva-83981 (URN)10.1186/s12903-026-08192-y (DOI)001755315900001 ()42026612 (PubMedID)2-s2.0-105037832726 (Scopus ID)
Tillgänglig från: 2026-05-04 Skapad: 2026-05-04 Senast uppdaterad: 2026-09-23Bibliografiskt granskad
3. Effect of Implant Design on Fracture Resistance, Mode, and Crystal Structure of One- and Two-Piece Zirconia Implants With Ceramic or Titanium Abutment Screws: An In Vitro Study
Öppna denna publikation i ny flik eller fönster >>Effect of Implant Design on Fracture Resistance, Mode, and Crystal Structure of One- and Two-Piece Zirconia Implants With Ceramic or Titanium Abutment Screws: An In Vitro Study
Visa övriga...
2026 (Engelska)Ingår i: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 37, nr 9, s. 1081-1095Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: To evaluate the fracture resistance, fracture modes, and crystalline phase changes of zirconia one-piece implants (OPI) and bone-level (BLTPI) or tissue-level, two-piece implants (TLTPI), with ceramic (C) or titanium (T) abutment screws after dynamic preloading in a moist environment. Materials and Methods: Dynamic preloading under moist conditions and subsequent static load-to-fracture testing were performed to evaluate fracture resistance and fracture mode. Scanning electron microscopy (SEM) analysis of fracture surfaces was employed to supplement the observations of macroscopic fracture modes. Crystalline phase changes were assessed using micro-Raman spectroscopy. Specimen preparations were performed in accordance with ISO 14801:2016. Five different ceramic (zirconia) implant designs were divided into the following groups: OPI, BLTPI (BLC, BLT), TLTPI (TLC, TLT). One-way and two-way ANOVA tests were used for comparisons and factor effect analysis. Results: Fracture resistance (N) and bending moment (N cm) differed significantly among the implant groups (p < 0.001), following the order TLTPI (775.2 ± 71 N) > OPI (605.7 ± 37 N) > BLTPI (498.3 ± 93 N). Within the two-piece implants (TPI), tissue-level designs (TL) outperformed bone-level designs (BL), while designs with different abutment screw materials showed no significant difference (p = 0.982). Conclusions: Within the limitations of this in vitro study, the evaluated zirconia-based OPI, BLTPI, and TLTPI systems demonstrate sufficient fracture resistance to support further clinical investigation. Implant-level design (TL vs. BL) influences mechanical performance, whereas the influence of abutment screw material (ceramic vs. titanium) is less pronounced and varies according to the implant-level design.

Ort, förlag, år, upplaga, sidor
John Wiley and Sons Inc, 2026
Nyckelord
bone-level implants, dental implants, implant design, implant fracture, tissue-level implants, zirconia implants
Nationell ämneskategori
Odontologi
Identifikatorer
urn:nbn:se:mau:diva-87151 (URN)10.1111/clr.70149 (DOI)001792673700001 ()42288470 (PubMedID)2-s2.0-105041489976 (Scopus ID)
Tillgänglig från: 2026-07-22 Skapad: 2026-07-22 Senast uppdaterad: 2026-09-23Bibliografiskt granskad

Open Access i DiVA

fulltext(31369 kB)204 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 31369 kBChecksumma SHA-512
468796cdc9ee7c7593933266523be85715a11b717c4b5f97a0c16fe14f4eb66800cc903c65299e53a4c6b6bb819247181713af42f64008da13e4a38121c9b45d
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Person

Gul, Abdulaziz

Sök vidare i DiVA

Av författaren/redaktören
Gul, Abdulaziz
Av organisationen
Odontologiska fakulteten (OD)
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 204 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 6367 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf