Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Interaction Phenomena between Dental Implants and Bone Tissue in Case of Misfit: A Pilot Study
Univ Padua, Ctr Mech Biol Mat, I-35131 Padua, Italy.;Univ Padua, Dept Ind Engn, I-35131 Padua, Italy..
Univ Padua, Ctr Mech Biol Mat, I-35131 Padua, Italy.;Univ Padua, Dept Ind Engn, I-35131 Padua, Italy..
Univ Pavia, Dept Clin Surg Diagnost & Paediat Sci, I-27100 Pavia, Italy..
Malmö universitet, Odontologiska fakulteten (OD).ORCID-id: 0000-0002-2893-3676
Vise andre og tillknytning
2023 (engelsk)Inngår i: Applied Sciences, E-ISSN 2076-3417, Vol. 13, nr 10, artikkel-id 6004Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The biomechanical response of cortical and trabecular bone tissues represents a fundamental aspect for the interpretation of the functional response of dental implants. In the case of misfit, the interaction phenomena occurring within the surgical and the subsequent healing phases must be interpreted primarily in the light of the response of bone tissue. This is influenced by the specific loadings induced, characterized by intensity and variable trends. The pilot study reported, which intentionally refers to a simple case of a two-implants frame, is addressed to define the method to approach the biomechanical investigation of the problem and to attest the necessity to integrate clinical competences with biomechanical analysis for interpreting different aspects of osseointegration. The action induced in cortical and trabecular bone regions depending on the implant frame conformation, the surgical procedure adopted, the varying condition at the bone-implant interface and the evolutionary trend of healing are the principal aspects to be considered to evaluate the osseointegration process. The biomechanical reliability of the specific implant frame is investigated in terms of bone-implant interaction by means of numerical models. This approach can offer valid information and support clinical practice under the fundamental condition that bone biomechanical behavior is properly characterized and represented in the model, in spite of the complex formulation to be adopted.

sted, utgiver, år, opplag, sider
MDPI, 2023. Vol. 13, nr 10, artikkel-id 6004
Emneord [en]
dental implants, osseointegration, misfit, bone mechanics, biomechanical reliability
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-60870DOI: 10.3390/app13106004ISI: 000995665600001Scopus ID: 2-s2.0-85160667088OAI: oai:DiVA.org:mau-60870DiVA, id: diva2:1769192
Tilgjengelig fra: 2023-06-16 Laget: 2023-06-16 Sist oppdatert: 2023-11-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Toia, Marco

Søk i DiVA

Av forfatter/redaktør
Toia, Marco
Av organisasjonen
I samme tidsskrift
Applied Sciences

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 76 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf