The Potential of Using Passive Cooling Roof Techniques to Improve Thermal Performance and Energy Efficiency of Residential Buildings in Hot Arid Regions
Laboratory of Design and Modeling of Architectural Ambiances and Urban Forms (LACOMOFA), Department of Architecture, Mohamed Khider University of Biskra, BP 145 RP, Biskra 07000, Algeria.ORCID-id: 0000-0002-3776-6742
Laboratory of Design and Modeling of Architectural Ambiances and Urban Forms (LACOMOFA), Department of Architecture, Mohamed Khider University of Biskra, BP 145 RP, Biskra 07000, Algeria.ORCID-id: 0000-0002-5416-4989
Malmö universitet, Fakulteten för kultur och samhälle (KS), Institutionen för Urbana Studier (US).ORCID-id: 0000-0001-7754-0927
Department of Buildings & Urban Environment, JUNIA HEI 13, Rue de Toul, 59000 Lille, France.
2022 (engelsk)Inngår i: Buildings, E-ISSN 2075-5309, Vol. 13, nr 1, s. 21-21Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In hot dry regions, the building envelope receives abundant solar radiation, which contributes to heat stress and indoor thermal discomfort. To mitigate overheating inside spaces, cooling is the main basic requirement during most of the year. However, due to the harsh climatic conditions, buildings fail to provide passively the required comfort conditions. Consequently, they are fully dependent on-air conditioning systems, which are huge energy consumers. As roofs are exposed to the sun throughout the daytime, they are estimated to be the main source of heat stress. In return, they can contribute significantly to achieve optimum comfort and energy savings when efficient design strategies are used in an early design stage. To examine the potential for cooling load reduction and thermal comfort enhancement by using cooling roof techniques in residential buildings, a study was performed in the city of Biskra (southern Algeria). Accordingly, an in-field measurement campaign was carried out on test-cells during five days in summer. Three different cooling roof techniques were addressed: (a) cool reflective white paint (CR), (b) white ceramic tiles (CT) and (c) a cool-ventilated roof (C-VR). These roofing alternatives were investigated by monitoring both roof surface temperatures and indoor temperatures. Comparative analysis showed that a cool-ventilated roof is the most efficient solution, reducing the average indoor temperature by 4.95 °C. A dynamic simulation study was also performed based on TRNSYS software to determine the best roofing system alternatives in terms of thermal comfort and energy consumption, considering the hottest month of the year. Simulation tests were run on a base-case model representing the common individual residential buildings in Biskra. Results showed that a double-skin roof combined with cool-reflective paint is the most efficient roofing solution. By comparison to a conventional flat roof, meaningful improvements have been achieved, including reducing thermal discomfort hours by 45.29% and lowering cooling loads from 1121.91 kWh to 741.09 kWh.

sted, utgiver, år, opplag, sider
MDPI, 2022. Vol. 13, nr 1, s. 21-21
Emneord [en]
cooling roof techniques, thermal comfort, energy efficiency, test cells, dynamic simulation, residential buildings, hot arid climate
HSV kategori
Forskningsprogram
Urbana studier; Hållbarhetsstudier
Identifikatorer
URN: urn:nbn:se:mau:diva-57294DOI: 10.3390/buildings13010021ISI: 000914450200001Scopus ID: 2-s2.0-85146524559OAI: oai:DiVA.org:mau-57294DiVA, id: diva2:1723267
Tilgjengelig fra: 2023-01-02 Laget: 2023-01-02 Sist oppdatert: 2024-02-05bibliografisk kontrollert

Open Access i DiVA

fulltext(2185 kB)246 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2185 kBChecksum SHA-512
792e3e6786ddf12ad164adb748f70cfce26be53d2712f0b9c50b807d7ad3a4add4c42a62eb22a535eee1457333ea6e1bf695c4a57238c2fe218f794bc51c3bc2
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Dabaieh, Marwa

Søk i DiVA

Av forfatter/redaktør
Athmani, WafaSriti, LeilaDabaieh, Marwa
Av organisasjonen
I samme tidsskrift
Buildings

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 246 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 125 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf