Effectivization of GAD ELISA: Method-transfer from Dynex DSX to Tecan Freedom EVOlyzer
Malmö universitet, Fakulteten för hälsa och samhälle (HS).
2022 (engelsk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
Abstract [en]

Due to a growing demand and need for faster results, effectivization as a concept has been pushed to the forefront of medical research. Here, a method transfer between 2 fully automized ELISA instruments is highlighted. The instruments were the Tecan Freedom EVOlyzer and the Dynex DSX.  The Tecan instrument is a more modern instrument with a more extensive LIMS integration, better automatization and increased capacity for samples and assays. The method being transferred was an Anti-GAD ELISA for the diagnosis of Type 1 Diabetes Mellitus. The study design was a result comparison of 20 samples with varying Anti-GAD concentration and 15 replicates of a single sample for a precision study. To successfully transfer the method, acceptance criteria concerning percentual difference in result, intermediate precision, and repeatability had to fall below 20 %. The assay was set up as a sandwich ELISA in accordance with the kit used at the laboratory (Euroimmun), where each sample was set as duplicates. Preliminary programming and testing was performed to ensure proper function. An average bias of +33 % was reported, as was an intra-run variation and an inter-run variation of ca 11 %. Additionally, a recurring issue with samples and calibrators in specific locations on the plate was reported. The issue was deemed systemic and possible solutions include changing programming parameters, or instrument part replacement. Ultimately the method transfer was left incomplete, and several technical details must be overcome before taking Anti-GAD analysis into routine use on the instrument.

sted, utgiver, år, opplag, sider
2022. , s. 31
Emneord [en]
Effectivization, Antibodies, ELISA, GAD, GAD65, Method transfer, Type 1 Diabetes Mellitus
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-52443OAI: oai:DiVA.org:mau-52443DiVA, id: diva2:1666981
Utdanningsprogram
HS Biomedicinsk laboratorievetenskap
Veileder
Examiner
Tilgjengelig fra: 2022-06-22 Laget: 2022-06-09 Sist oppdatert: 2022-06-22bibliografisk kontrollert

Open Access i DiVA

fulltext(1284 kB)294 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 1284 kBChecksum SHA-512
fd6e146c05d38bcfd31366b80ca80651491cee02a7b6d463cbb0415a4714dd2691d43cec21006d5cf4cc96b7edfe12d440c22c60954915a186cbf86a72947221
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Bernal Salazar, Juan Manuel
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 296 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 388 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf