Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Ventilated Trombe wall as a passive solar heating and cooling retrofitting approach: a low-tech design for off-grid settlements in semi-arid climates
Department of Architecture and Built Environment, LTH, Lund University, Sweden.ORCID-id: 0000-0001-7754-0927
Department of Architecture, German University in Cairo, Egypt.
2015 (engelsk)Inngår i: Solar Energy, ISSN 0038-092X, E-ISSN 1471-1257, Vol. 122, s. 820-833Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In the coming years, it is anticipated that if we continue with the same pace of energy consumption, communities will continue to face three major challenges; a mounting increase in energy demands, pollution, and global warming. On a local scale, Egypt is experiencing one of its most serious energy crises in decades. The energy consumed in indoor cooling and heating is the biggest portion of total energy consumption in residential buildings. This paper is an experimental simulation study for building retrofitting in off-grid settlements in semi-arid climates, using Trombe wall as a low-tech passive heating and cooling solution. In this study, we made developments to the conventional classic Trombe wall using occupant-centered design and living lab experimental methods. The thermal efficiency of the proposed Trombe wall design is simulated during winter and summer peaks. In the proposed design we used gray paint instead of typical black paint in addition to 15 cm reversible natural wool insulation and two 3 mm thick roll-up wool curtains. The new design reduced the heating load by 94% and reduced the cooling load by 73% compared to the base case with an annual energy savings of 53,631 kW h and a reduction in CO2 emissions of 144,267 kg of CO2. The living lab test proved that the proposed design of the Trombe wall is economically viable and the payback time is 7 months. It is recommended that the proposed design be monitored for a whole year to have an accurate assessment of its efficiency. A post occupancy evaluation is also needed to measure local residents’ acceptance and perceived comfort after retrofitting.

sted, utgiver, år, opplag, sider
Elsevier, 2015. Vol. 122, s. 820-833
Emneord [en]
Trombe wall; Passive solar heating and cooling; Semi-arid climate; Energy consumption; Low-tech retrofitting; Occupant centered approach
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-47420DOI: 10.1016/j.solener.2015.10.005ISI: 000367107500073Scopus ID: 2-s2.0-84945311491OAI: oai:DiVA.org:mau-47420DiVA, id: diva2:1619978
Tilgjengelig fra: 2021-12-14 Laget: 2021-12-14 Sist oppdatert: 2025-09-17bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Dabaieh, Marwa

Søk i DiVA

Av forfatter/redaktør
Dabaieh, Marwa
I samme tidsskrift
Solar Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 216 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf