Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Influence of tooth-supported guide design and sterilization procedure on the precision of static computer-guided single implant surgery - An in vitro study
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
2021 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

Purpose: The purpose of this in vitro study was to assess the accuracy of two surgical guides of differing size, as well as evaluate possible deformation of surgical guides following sterilization.

Material and methods: Sixty maxillary 3D-printed models were fabricated with the first premolar missing. Sixty surgical guides were preoperatively designed (3Shape Implant Studio) and fabricated using a digital light-processing printer (Vida, Envisiontec). Thirty guides were designed with the support of four teeth and thirty guides with the support of six teeth. Sixty dental implants were inserted using fully guided surgery, digital scan of dental implants was performed (Atos Core 135, GOM). The surgical guides were sterilized using steam heat. Corresponding datasets of the planned and final dental implant position as well as datasets of pre- and post-sterilization were analyzed (GOM Inspect 2017, GOM Metrology). For implant position, deviation at entry point; deviation at apex; vertical deviation; horizontal deviation (mm) and angular deviation (degrees) was measured. For post-sterilization evaluation, central sleeve position (mm) and angular deviation (degrees) was measured.

Results: No statistically significant differences in implant position deviation were found between the groups (p < 0.05). A statistically significant difference was found in angular deviation between the groups (p = 0.031).

Conclusion: The results in this study indicate a similar accuracy of a surgical guide with two mesial respectively distal tooth supports in comparison to a guide with three mesial and three distal tooth supports. Larger guides appear to be more affected by heat sterilization with regard to angular deviation.

sted, utgiver, år, opplag, sider
2021. , s. 23
Emneord [en]
computer-guided implant surgery, dental implant, guided surgery, sterilization, surgical guide design
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-42955OAI: oai:DiVA.org:mau-42955DiVA, id: diva2:1562199
Eksternt samarbeid
Folktandvården AB
Utdanningsprogram
OD Tandläkarutbildning
Veileder
Examiner
Tilgjengelig fra: 2021-06-08 Laget: 2021-06-08 Sist oppdatert: 2022-06-27bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Søk i DiVA

Av forfatter/redaktør
Anderberg, EllaSaad, Tina
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 330 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf