Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Orthodontic diagnostics and measurements on digital study models made with an intraoral scanner
Malmö högskola, Odontologiska fakulteten (OD).
2013 (svensk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [sv]

Introduktion: Modellanalys har traditionellt gjorts på fysiska gipsmodeller. Idag finns ny teknik som möjliggör framställning av digitala modeller utan behov av konventionella avtryck. Syftet med den här studien är att undersöka tillförlitligheten hos digitala modeller framställda med en intraoral scanner, patientupplevelsen och olika tidsaspekter förenade med tekniken. Metod: På ett urval av 20 vuxna personer gjordes både konventionell avtryckstagning och en intraoral scanning (TRIOS, 3Shape) av bettet för framställning av gipsmodeller och digitala modeller. Den kliniska tidsåtgången mättes och personerna besvarade ett frågeformulär gällande sin upplevelse av metoderna. Fyra observatörer diagnostiserade bettrelationer och utförde ortodontiska mätningar på gipsmodeller med ett skjutmått och digitala modeller med OrthoAnalyzer Orthodontics (3Shape, Danmark). Tidsåtgången mättes för digital- respektive konventionell modellanalys. Statistiska analyser gjordes utifrån Paired samples t test, korstabeller och frekvensanalys. Resultat: Diagnostik av horisontella-, vertikala- och transversella bettrelationer på digitala modeller har hög tillförlitlighet. Få statistiskt signifikanta skillnader fanns för linjära mätningar på digitala modeller jämfört med gipsmodeller. För majoriteten av observatörerna tog digital modellanalys längre tid än konventionell modellanalys. Likaså var den kliniska tidsåtgången för intraoral scanning signifikant längre än för konventionell avtryckstagning och metoden prioriterades lägre av försökspersonerna. Konklusion: Digitala modeller framställda med en intraoral scanner är en tillförlitlig metod för ortodontisk diagnostik och terapiplanering. Tekniken har en rad fördelar och förbättras ständigt men dess acceptans för den enskilde klinikern blir i slutändan en kostnadsfråga.

Abstract [en]

Introduction: Model analysis has traditionally been carried out on physical plaster models. New technology allows the production of digital models without the need for conventional impressions. The purpose of this study was to evaluate the validity of digital models made with an intraoral scanner, patient experience and different time aspects associated with this technology. Methods: A sample of 20 adults was selected. Plaster models and digital models were obtained from conventional impressions and an intraoral scanning (TRIOS, 3Shape) respectively. The clinical time required for impression taking and intraoral scanning was recorded and the subjects were asked to answer a questionnaire regarding their experience of both methods. Four independent examiners diagnosed malocclusions and performed measurements with a digital caliper on plaster models and by using OrthoAnalyzer Orthodontics (3Shape, Denmark) for digital models. Time required for digital- and conventional model analysis respectively, was recorded. Statistical analysis was performed by using Paired samples t test, crosstabs and frequency analysis. Results: Diagnostics of horizontal-, vertical- and transversal malocclusions with digital models showed high validity. Few statistically significant differences were found for measurements made on digital models compared to direct measurements on plaster models. For a majority of the examiners, digital model analysis was more time consuming than conventional model analysis. Also, clinical time required for intraoral scanning was significantly greater than for conventional impression taking. The subjects preferred conventional impression taking. Conclusions: Digital models made with an intraoral scanner are a reliable method for orthodontic diagnostics and treatment planning. The technique has a number of advantages and is constantly improving but its acceptance depends ultimately on the cost-effectiveness ratio to the individual practitioner.

sted, utgiver, år, opplag, sider
Malmö högskola/Odontologiska fakulteten , 2013. , s. 37
Emneord [sv]
Diagnostics, Digital model, Intraoral scanner, Plaster model, Validity, Diagnostik, Digital modell, Gipsmodell, Validitet
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-19970Lokal ID: 15427OAI: oai:DiVA.org:mau-19970DiVA, id: diva2:1479815
Utdanningsprogram
OD Tandläkarutbildning
Tilgjengelig fra: 2020-10-27 Laget: 2020-10-27 Sist oppdatert: 2022-06-27bibliografisk kontrollert

Open Access i DiVA

fulltekst(351 kB)106 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 351 kBChecksum SHA-512
9692a969e7368413cea92c8a2399915a4d38c9f564a2f4199a34f01916d14e68ca8a5e1da6f22a9a3cc9240dbbfe83b34177d55975f6cd3eeb2d17ad873eaef2
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 107 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 264 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf