Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Diagnostic Accuracy of Radiological Methods Regarding Root Resorption of Teeth Neighbouring Impacted Maxillary Canines - A systematic review
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
2019 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [sv]

Syfte: Syftet med denna studie var att systematiskt granska den vetenskapliga litteraturen gällande diagnostisk tillförlitlighet för röntgenmetoder avseende rotresorption på granntänder till överkäkshörntanden. Material och metod: För att uppnå en systematisk och ett transparant tillvägagångssätt användes PRISMA och CRDs handbok. Sökningen gjordes i fyra olika databaser, PubMed, Cochrane, Web of Science och Scopus av de två författarna. De inkluderade studierna kvalitetsgranskades enligt QUADAS-2 dokument. Resultat: Sökningen resulterade i 2175 studier. Fem studier inkluderades i denna systematiska litteraturöversikt och alla rapporterade diagnostisk tillförlitlighet. Intraoral periapikal röntgen, panorama, CT och CBCT var olika indextest i studierna. Extraherade tänder, CT och CBCT användes som referensstandard. Låg risk för bias visades i ungefär hälften av domänerna gällande risk för bias och för alla domäner gällande applicerbarhet. Tillförlitligheten hos tredimensionell röntgen varierade mellan 0,85-1,0 och tillförlitligheten hos tvådimensionell röntgen varierade från 0,45 till 0,78. Konklusion: Denna systematiska litteraturöversikt visade att tredimensionell röntgen hade högst sensitivitet och specificitet gällande rotresorption på granntänder till överkäkshörntänder. CBCT visade en högre tillförlitlighet än tvådimensionell röntgen. Även om CBCT har högre tillförlitlighet så har den också en högre strålningsdos och är inte alltid fördelaktig.

Abstract [en]

Aim: The aim of this study was to systematically review the scientific literature in diagnostic accuracy of radiographic methods regarding root resorption of teeth neighbouring impacted maxillary canines. Material and method: In order to get a systematic and transparent approach, the PRISMA statement and CRD’s guidance was followed. Four databases were searched, PubMed, Cochrane, Web of Science and Scopus by the two authors. The included studies were evaluated by the QUADAS-2 tool for quality assessment. Result: The search resulted in 2175 studies. Five studies were included in this review and all of them reported diagnostic accuracy. Intraoral periapical radiograph, panorama, CT and CBCT was used as index test among the studies. Extracted teeth, CT and CBCT was used as reference test. Low risk of bias was shown in approximately half of the domains for risk of bias and for all domains regarding applicability. The accuracy of three-dimensional ranged from 0.85-1.0 and the accuracy of two-dimensional ranged from 0.45-0.78. Conclusions: According to this systematic review, three-dimensional imaging showed the highest sensitivity and specificity regarding root resorptions caused by impacted maxillary canine. CBCT showed higher accuracy than two-dimensional imaging. Though, CBCT has higher accuracy it also has a higher radiation dose and might not always be beneficial regarding treatment planning. Therefore, CBCT should be used with respect and not routinely.

sted, utgiver, år, opplag, sider
Malmö universitet/Odontologiska fakulteten , 2019. , s. 28
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-19748Lokal ID: 29769OAI: oai:DiVA.org:mau-19748DiVA, id: diva2:1479592
Utdanningsprogram
OD Tandläkarutbildning
Veileder
Examiner
Tilgjengelig fra: 2020-10-27 Laget: 2020-10-27 Sist oppdatert: 2022-06-27bibliografisk kontrollert

Open Access i DiVA

fulltekst(1754 kB)312 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1754 kBChecksum SHA-512
886037cb206166882388402d149a49de171442934d2004c6340883bb24638377d646888a20e220ae02e83eaa73f15b6bdd00a4258e4a6aa1187bff2a9d62700d
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 312 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 265 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf