Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Earth air heat exchanger, Trombe wall and green wall for passive heating and cooling in premium passive refugee house in Sweden
Malmö universitet, Fakulteten för kultur och samhälle (KS), Institutionen för Urbana Studier (US). Aalborg Univ, Dept Architecture Design & Media Technol, Aalborg, Denmark..ORCID-id: 0000-0001-7754-0927
Hokaido Univ, Environm Syst Engn Lab, Sapporo, Hokkaido, Japan.;Benha Univ, Shoubra Fac Engn, Banha, Egypt..
2020 (engelsk)Inngår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 209, artikkel-id 112555Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

With the increasing number of migrants and refugees, there is a need for energy-efficient and low impact temporary housing that can accommodate millions of displaced peoples worldwide. This study describes a design proposal for a premium passive refugee house that uses three main passive heating and cooling solutions (Earth Air Heat Exchanger, Trombe wall, and green wall) and is suited to the Swedish climate. The purpose of the combination of the three passive systems is to reduce cooling and heating loads to conserve a significant amount of primary energy and thus mitigate the impact of the house's energy use on the environment through a reduction in emissions. The house is designed to fulfill its energy needs from renewable sources and produce an annual surplus of 180 kWh/m(2)/annum. The methodology applied is a dynamic system modeling and simulation approach using TRNSYS and ANSYS software. The simulation results showed a heating load of 7.9 kWh/m(2)/annum and a cooling load of 2.8 kWh/m(2)/annum, with total energy consumption reaching 18.4 kWh/m(2)/annum. Preliminary feasibility costing showed a payback time of 7.4 years out of the 25-years suggested lifetime of building using the three passive solutions. The amount of CO2 emissions is 231.1 kg CO(2)e/annum with a primary energy demand of 0.032 GJ/m(2)/annum. As a follow-up to the initial study, a proof of concept has been implemented in Lund, Sweden, in an urban living lab to verify the simulation results through a 12-month post-occupancy monitoring and evaluation study.

sted, utgiver, år, opplag, sider
Elsevier, 2020. Vol. 209, artikkel-id 112555
Emneord [en]
Premium passive house, Refugee housing, CFD simulation, EAHE, Green wall, Trombe wall
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-17233DOI: 10.1016/j.enconman.2020.112555ISI: 000524307600019Scopus ID: 2-s2.0-85081006362OAI: oai:DiVA.org:mau-17233DiVA, id: diva2:1429802
Tilgjengelig fra: 2020-05-12 Laget: 2020-05-12 Sist oppdatert: 2024-02-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Dabaieh, Marwa

Søk i DiVA

Av forfatter/redaktør
Dabaieh, Marwa
Av organisasjonen
I samme tidsskrift
Energy Conversion and Management

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 334 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf