Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Validation Study of the Impression Replica Technique.
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Malmö universitet, Odontologiska fakulteten (OD).
Vise andre og tillknytning
2019 (engelsk)Inngår i: Journal of Prosthodontics, ISSN 1059-941X, E-ISSN 1532-849X, Vol. 28, nr 2, s. e609-e616Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

PURPOSE: To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. MATERIALS AND METHODS: The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. RESULTS: The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 mum. CONCLUSION: The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry.

sted, utgiver, år, opplag, sider
John Wiley & Sons, 2019. Vol. 28, nr 2, s. e609-e616
Emneord [en]
Internal gap, marginal gap, misfit, production tolerance
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-6937DOI: 10.1111/jopr.12795ISI: 000458904300043PubMedID: 29664193Scopus ID: 2-s2.0-85045757643Lokal ID: 26706OAI: oai:DiVA.org:mau-6937DiVA, id: diva2:1403891
Tilgjengelig fra: 2020-02-28 Laget: 2020-02-28 Sist oppdatert: 2024-02-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Braian, MichaelAmeri, ArmanAhlgren, Camilla

Søk i DiVA

Av forfatter/redaktør
Braian, MichaelAmeri, ArmanAhlgren, Camilla
Av organisasjonen
I samme tidsskrift
Journal of Prosthodontics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 195 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf