Malmö University Publications
System disruptions
There are recurring service disruptions on some of the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Konnektortjocklekens inverkan på hållfastheten i en treleds-implantatbrounderkonstruktion av PEEK med hjälp av finita elementmetodenFinita elementmetoden för hållfasthetsanalys av treleds-implantatbrounderkonstruktioner av PEEK med varierande konnektordimensioneringKonnektordimensionens betydelse för hållfastheten i treleds-implantatbrounderkonstruktioner av PEEK; En finita elementanalys
Malmö högskola, Faculty of Odontology (OD).
Malmö högskola, Faculty of Odontology (OD).
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Sammanfattning Syfte Syftet med föreliggande studie är varär att med en finita elementanalys (FEA) undersöka hållfastheten i implantatförankrade treleds-brounderkonstruktioner av materialet PEEK beroende på konnektordimension och belastningsvinkel med hjälp av finita elementmetoden (FEM) genom att analysera spänningskoncentration, displacering och töjning. i implantatförankrade treleds-brounderkonstruktioner i materialet PEEK beroende på konnektortjocklek och belastningsvinkel med hjälp av finita elementmetoden (FEM). Material och Metod Tre Ddigitala implantatförankrade brokonstruktioner 44-46 i PEEK respektive zirkconia med konnektordimensionerna konnektorarean 12 mm2, 14 mm2 och 16 mm2 f framställdes i ett CAD-program. Grupperna med konnektordimensionen 16 mm2 utgjorde intern (P-16) respektive extern (Z-16) kontrollgrupp. Därefter Dessa belastades dessa med hjälp av med en programvara för FEM FEA på ponticen med kraften 500 N i vinklarna axiell (0°) och vinklad ( 30°) riktning. Värdena för spänningskoncentration, displacering och töjning visualiserades och analyserades. Resultat Resultaten visade att högst spänningsvärden uppstod i PEEK-konstruktionen med konnektorarean 12 mm2 under en vinklad belastning, samt att lägst spänningsvärden uppstod i PEEK-konstruktionen med konnektorarean 14 mm2 under axiell belastning. Endast i kontrollgrupperna, PEEK respektive zirkonia 16 mm2P-16 respektive Z-16 uppstod den maximala spänningskoncentrationen ocklusalt istället för vid konnektorn, även om höga spänningsvärden fortfarande kunde utläsas cervikalt på konnektorn. Högre displacerings- och töjningsvärden kunde iakttas i samtliga PEEK-grupper jämfört med zirkonia-grupperna, oavsett konnektortjocklek konnektordimension och belastningsvinkel. Slutsats Inom ramen för följande föreliggande studiesrs begränsningar kan följande slutsatser dras: • En underdimensionerad konnektor har en negativ inverkan på hållfastheten i implantatförankrade treleds-brounderkonstruktioner av PEEK då de maximala spänningskoncentrationernas lokalisering förflyttas till mer kritiska områden i konnektorområdet. • En vinklad belastning ökar spänningarna, displaceringen och töjningen i implantatförankrade brounderkonstruktioner oavsett material eller konnektortjocklekkonnektordimension. • Spänningsvärden och spänningsfördelning är likartade i implantatförankrade treleds-underkonstruktioner av PEEK och zirkonia, men är mer kritiska för PEEK. • Displacerings- och töjningsvärden är högre i PEEK- än i zirkonia-implantatförankrade treleds-underkonstruktioner.

Abstract [en]

Abstract Purpose The aim of the study was is to examine the strength ofin three-unit implant-supported frameworks made of PEEK, depending on connector dimension and loading direction utilizing via a finite element analysis-method (FEAM) by analyzing the stress concentration, displacement and strain. in three-unit implant-supported frameworks made of PEEK, depending on connector dimension and loading direction utilizing a finite element-method (FEM). Material and method Implant-supported frameworks, 44-46, of PEEK and zirconia with connector dimensions area 12 mm2, 14 mm2 and 16 mm2 was produced by CAD. Via FEAM-software the pontic was loaded with 500 N angled at 0° and 30°. Values for stress, displacement and strain were analyzed. Results Maximum stress values ​​occurred in PEEK with the connector area 12 mm2 under angled loading and minimum stress​​ in PEEK with 14 mm2 under axial loading. In the control groups, P/Z 16 mm2, maximum stress arose occlusally, but high stress remained in the cervical connector area. Higher displacement and strain values for displacement and strain waswere observed in all PEEK-groups compared to zirconia, regardless of connector dimension and load angulation of the load. Conclusion Within the limitations of this the study, the following conclusions were made: • An under-dimensioned connector have a negative impact on the strength of three-unit implant-supported frameworks made of PEEK since the location of the maximum stress appears in more critical areas – the connector areas. • Inclined loading increases stress, displacement and strain in three-unit implant-supported frameworks regardless of material or connector dimension. • Stress values and stress distribution are similar in three-unit implant-supported frameworks made from of PEEK as well as zirconia, but affects PEEK more critically. • Higher displacement and strain values were observed in three-unit implant-supported frameworks of PEEK compared to zirconia.

Place, publisher, year, edition, pages
Malmö högskola/Odontologiska fakulteten , 2016. , p. 2
Keywords [sv]
PEEK, FEA, Finita elementanalys, konnektordimension
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:mau:diva-19851Local ID: 21131OAI: oai:DiVA.org:mau-19851DiVA, id: diva2:1479696
External cooperation
T Technology
Educational program
OD Tandteknikerutbildning
Available from: 2020-10-27 Created: 2020-10-27 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

fulltext(145 kB)50 downloads
File information
File name FULLTEXT01.pdfFile size 145 kBChecksum SHA-512
a3f690bc923ef44febe54e77fad2ff2523cd2a3bfe3405bd1f7532a12a2edba3ef6fce89dd84930089b2d100586af399ba7263b66128cdaae64240db13da29be
Type fulltextMimetype application/pdf

By organisation
Faculty of Odontology (OD)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 50 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 119 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf