Johansson, C. (2026). High Translucent and Multilayer Zirconium Dioxide Ceramic Materials for Dental Restorations: Studies on how processing factors influence material properties. (Doctoral dissertation). Malmö: Malmö University Press
Open this publication in new window or tab >>High Translucent and Multilayer Zirconium Dioxide Ceramic Materials for Dental Restorations: Studies on how processing factors influence material properties
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Zirconia materials are widely used for dental restorations to replace missing teeth, as they offer favourable mechanical properties, excellent biocompatibility, and good aesthetics. To improve the aesthetics of restorations, several zirconia types with highly varying material properties have been developed in different generations. Given the widespread use of these materials, it is essential to ensure the long-term performance of zirconia restorations to provide predictable and patient-safe treatments.

The overall findings of the thesis emphasize that laboratory and clinical-related processing factors influence the microstructure, crystal structure, and thus the properties of high translucent and multilayer zirconia differently depending on the zirconia type. Therefore, zirconia materials should be selected with awareness based on the specific clinical requirements of each patient and handled based on the zirconia type.

The various zirconia types are stabilized with different amount of yttria, typically 3-6%, and are therefore called 3-, 4-, 5-, and 6YSZ (yttria-stabilized zirconia). Multilayer zirconia materials consisting of either layers with different zirconia types and properties (composition-gradient) or layers with different shades (shade-gradient) have also been developed. Since the yttria content differs between zirconia types, the microstructure, crystal structure, and material properties also differ significantly.

During the manufacturing of restorations in the dental laboratory, several processing steps – such as sintering, grinding, polishing, and glazing – are required. In the clinic, the restoration is adjusted by grinding and polishing for adaptation to the patient's dentition. These processing factors can have a significant effect on the properties of zirconia, and these effects can vary between zirconia types, potentially compromising the longevity of the restoration. The overall aim of the thesis was therefore to evaluate the influence of laboratory and clinical-related processing factors on the material properties of high translucent and multilayer zirconia materials.

Study I, a systematic review, evaluated how processing factors and time-related factors affect the material properties of specific zirconia types. The results showed that 3YSZ should be sintered according to the manufacturer's recommendation and polished before glazing to favour strength, surface roughness, and wear behaviour. Polishing after clinical adjustments by grinding is necessary to favour ageing resistance and roughness. The results were dependent upon zirconia brand, and the evidence relating to other zirconia types and processing factors was too limited for conclusions to be drawn.

Based on the knowledge gaps identified in Study I, two laboratory studies were conducted.

Study II investigated the influence of laboratory polishing, glazing, and clinical adjustments on the mechanical and surface properties of multilayer zirconia materials. Composition-gradient zirconia should be polished, and shade-gradient zirconia should be polished and glazed in the laboratory to favour strength and surface roughness. Clinical adjustments of zirconia with high yttria content (≥ 5YSZ) are detrimental for the strength and should be performed with caution.

Study III evaluated the influence of sintering programmes on the microstructure, crystal structure, optical and mechanical properties of multilayer zirconia. The density and strength of multilayer zirconia are material dependent and are not significantly affected by the sintering programme. Shorter sintering programmes reduce the tetragonal crystal phase of composition-gradient zirconia. Further research is required to verify that shorter sintering programmes result in equivalent material properties as conventional sintering.

In conclusion, high translucent and multilayer zirconia materials require material- specific handling during the manufacturing and clinical adjustments of restorations. Sintering influences the microstructure, crystal structure, and potentially the properties of zirconia and should be performed according to the manufacturer's recommendations. Polishing is preferable over glazing in the laboratory and necessary after adjustments in the clinic.

Abstract [sv]

Zirkonia-material används ofta till tandersättningar för att ersätta saknade tänder, på grund av deras styrka (hållfasthet), vävnadsvänlighet och goda estetik. Med tanke på den omfattande användningen av zirkonia är det viktigt att säkerställa att zirkonia-ersättningarna håller länge och därmed bidrar till förutsägbara och patientsäkra behandlingar.

För att förbättra tandersättningars estetik har ett flertal zirkonia-typer, med vitt skilda egenskaper och användningsområden, utvecklats i olika generationer. Det finns även flerskiktade zirkonia-material som antingen består av lager med olika zirkonia-typer, för att kunna kombinera styrka och estetik, eller lager med olika färgnyanser.

Avhandlingens övergripande resultat visar att de framställningssteg (processfaktorer) som utförs under tillverkningen av tandersättningar påverkar zirkonia-materialens inre struktur och egenskaper olika beroende på zirkonia-typ. Därför bör zirkonia-material väljas med eftertanke utifrån specifika patientfall och hanteras utifrån zirkonia-typ.

Framställningsstegen på tandtekniska laboratorier omfattar bland annat sintring, slipning, polering och glansbränning (glasering). På kliniken justeras tandersättningen genom slipning och polering för att anpassas till patientens bett. Dessa processfaktorer kan ha en betydande inverkan på zirkonias egenskaper. Effekten kan dessutom variera mellan zirkonia-typerna, vilket kan äventyra zirkonia-ersättningars livslängd.

Det övergripande syftet med avhandlingen var därför att utvärdera hur laboratorie- och kliniskt relaterade processfaktorer påverkar materialegenskaperna hos högtranslucenta och flerskiktade zirkonia-material.

Delstudie I, en systematisk litteraturöversikt, utvärderade hur process- och tidsrelaterade faktorer påverkar materialegenskaper hos de specifika zirkonia- typerna. Resultaten visade att starkare högtranslucenta zirkonia-material (3YSZ) bör sintras enligt fabrikantens rekommendationer och poleras före glansbränning för att främja hållfasthet, ytjämnhet och slitagebeteende. Polering efter kliniska justeringar genom slipning är nödvändigt för att främja åldringsresistens och ytjämnhet. Resultaten var beroende av zirkonia-fabrikat och beläggen (evidensen) för övriga zirkonia-typer och processfaktorer var för begränsade för att några slutsatser skulle kunna dras.

Baserat på de identifierade kunskapsluckorna i Delstudie I genomfördes två laboratoriestudier.

Delstudie II undersökte inverkan av laboratoriepolering, glansbränning och kliniska justeringar på hållfasthet och ytegenskaper hos flerskiktade zirkonia-material. Flerskiktad zirkonia med zirkonia-typ-lager bör poleras, och zirkonia med färglager bör poleras och glansbrännas på laboratoriet, för att främja hållfasthet och ytjämnhet. Kliniska justeringar av högestetisk zirkonia (≥ 5YSZ) sänker hållfastheten och bör utföras med försiktighet.

Delstudie III utvärderade sintringsprogram med olika längd: konventionell sintring och snabbsintring. Sintringsprogrammens effekt på den inre materialstrukturen (mikrostruktur och kristallstruktur), translucensen, hållfastheten och frakturresistensen hos flerskiktad zirkonia undersöktes. Densiteten och hållfastheten är materialberoende och högre för zirkonia med zirkonia-typ-lager, men de påverkas inte av sintringsprogram. För att bekräfta att snabbsintring resulterar i likvärdiga materialegenskaper som konventionell sintring krävs emellertid ytterligare studier.

Sammanfattningsvis kräver högtranslucenta och flerskiktade zirkonia-material materialspecifik hantering under framställningen och justeringen av tandersättningar. Sintring påverkar mikrostrukturen och kristallstrukturen och potentiellt zirkonias egenskaper och bör utföras enligt fabrikantens rekommendationer. Polering är att föredra framför glansbränning på laboratoriet och nödvändigt efter justeringar på kliniken.

Place, publisher, year, edition, pages
Malmö: Malmö University Press, 2026. p. 214
Series
Malmö University Odontological Dissertations, ISSN 1650-6065, E-ISSN 2004-9307
National Category
Odontology
Identifiers
urn:nbn:se:mau:diva-88467 (URN)10.24834/isbn.9789178777907 (DOI)978-91-7877-789-1 (ISBN)978-91-7877-790-7 (ISBN)
Public defence
2026-10-30, Odontologiska fakulteten KL:2370 Aulan, Smedjegatan 16, Malmö, 09:15 (English)
Opponent
Supervisors
Note

Paper III in dissertation as manuscript. 

Available from: 2026-10-01 Created: 2026-10-01 Last updated: 2026-10-09Bibliographically approved
Johansson, C., Eqtesadi, S., Slagtern Fjellvåg, A., Larsson, C. & Papia, E. (2026). Influence of sintering programs on microstructure, crystal phase composition, and optical and mechanical properties of multilayer zirconia. Dental Materials
Open this publication in new window or tab >>Influence of sintering programs on microstructure, crystal phase composition, and optical and mechanical properties of multilayer zirconia
Show others...
2026 (English)In: Dental Materials, ISSN 0109-5641, E-ISSN 1879-0097Article in journal (Refereed) Epub ahead of print
Abstract [en]

Objectives

To evaluate the influence of different sintering programs on the density, crystal phase composition, and biaxial flexural strength of composition- and shade-gradient multilayer zirconia (YML/STML). In addition, the microstructure, transmittance, and indentation fracture (IF) resistance were descriptively analyzed.

Methods

Specimens of KATANA™ Zirconia YML, containing Body 1 and 2 layers, and STML were divided into three groups depending on sintering program, each with specific sintering parameters: high-speed for 20min (YH20/SH20), speed for 90min (YS90/SS90), and conventional sintering for 7h (YC/SC). Density and flexural strength were analyzed using two-way ANOVA with the factors: material and sintering program (α = .05). Microstructure, phase composition, transmittance, and IF resistance were descriptively analyzed.

Results

YML exhibited significantly higher density and flexural strength than STML. The sintering programs showed no statistically significant effect on density or flexural strength. The descriptive analyses showed higher t phase fraction and IF resistance, and lower yttria, t'', and c content, grain size, and transmittance of YML compared to STML. Grain size was similar across YML sintering groups but differed among STML groups (S90<SC<SH20). For YML, an increase in the t phase fraction was observed for prolonged sintering programs (YH20<YS90<YC), with reservation for the limited sample size. Transmittance was lower for YS90 compared to YH20 and YC.

Significance

The density and flexural strength of composition-gradient and shade-gradient multilayer zirconia are material dependent and are not significantly influenced by the sintering program. For composition-gradient zirconia, speed and particularly high-speed sintering programs may reduce the t phase fraction.

Place, publisher, year, edition, pages
Elsevier, 2026
Keywords
Biaxial flexural strength ; Density ; Grain size ; Indentation fracture resistance ; Phase partitioning ; Shade-gradient ; Speed sintering ; Strength-gradient ; Transmittance ; YSZ
National Category
Odontology
Identifiers
urn:nbn:se:mau:diva-88474 (URN)10.1016/j.dental.2026.09.012 (DOI)42844047 (PubMedID)2-s2.0-105052775387 (Scopus ID)
Available from: 2026-10-01 Created: 2026-10-01 Last updated: 2026-10-22Bibliographically approved
Johansson, C., Larsson, C. & Papia, E. (2025). Biaxial flexural strength and surface characterization of multilayer zirconium dioxide after polishing, glazing and clinical adjustments. Journal of The Mechanical Behavior of Biomedical Materials, 166, Article ID 106930.
Open this publication in new window or tab >>Biaxial flexural strength and surface characterization of multilayer zirconium dioxide after polishing, glazing and clinical adjustments
2025 (English)In: Journal of The Mechanical Behavior of Biomedical Materials, ISSN 1751-6161, E-ISSN 1878-0180, Vol. 166, article id 106930Article in journal (Refereed) Published
Abstract [en]

PURPOSE: To evaluate how laboratory polishing and glazing and clinical adjustments, i.e., by grinding and polishing affect the biaxial flexural strength and surface characterization of multilayer zirconia.

METHODS: Specimens of KATANA™ Zirconia YML, containing Enamel-Body 1 or Body 2-3 layers, and UTML were divided into 18 groups (n = 11) according to material/layer and finish treatment: laboratory polishing, glazing, or both, or followed by clinical adjustments. The surface roughness, surface structure and elemental composition were evaluated. Thermocyclic-mechanical cyclic loading and biaxial flexural strength test were performed. Three- and two-way ANOVA were used (α = 0.05).

RESULTS: The yttrium amount decreased in the order UTML, YML Enamel-Body 1, and YML Body 2-3. Body 2-3 showed higher flexural strength than Enamel-Body 1 and UTML, in that order. Flexural strength after clinical adjustments was higher in Body 2-3 but lower in Enamel-Body 1 and UTML. Finish treatments had indistinguishable impact on Enamel-Body 1. Body 2-3 had higher strength after polishing, polishing and glazing, and glazing, in that order. UTML displayed the highest strength after polishing and glazing or glazing. The surface roughness was lowest after polishing regardless of material/layer.

CONCLUSIONS: Laboratory treatments and clinical adjustments of multilayer zirconia affect the flexural strength and surface roughness differently depending on the zirconia type. Composition-gradient zirconia should be polished, and shade-gradient zirconia (≥ 5 mol% yttria) should be polished and glazed. Clinical adjustments of zirconia with higher yttria content are detrimental for the flexural strength and should be performed with caution.

Place, publisher, year, edition, pages
Elsevier, 2025
Keywords
Elemental composition, Grinding, Microstructure, Strength-gradient, Surface finish treatment, Surface roughness, YSZ
National Category
Odontology
Identifiers
urn:nbn:se:mau:diva-74306 (URN)10.1016/j.jmbbm.2025.106930 (DOI)001432447900001 ()39987645 (PubMedID)2-s2.0-85218269074 (Scopus ID)
Available from: 2025-02-24 Created: 2025-02-24 Last updated: 2026-10-01Bibliographically approved
Johansson, C., Larsson, C. & Papia, E. (2025). Should we polish or glaze multilayer zirconia?. Dental Materials, 41(s2), e26-e27
Open this publication in new window or tab >>Should we polish or glaze multilayer zirconia?
2025 (English)In: Dental Materials, ISSN 0109-5641, E-ISSN 1879-0097, Vol. 41, no s2, p. e26-e27Article in journal, Meeting abstract (Other academic) Published
Abstract [en]

Purpose / Aim: The study aimed to investigate the effect of laboratory polishing and glazing and clinical adjustments by grinding and polishing on the biaxial flexural strength and surface characterization of multilayer zirconium dioxide.

Materials & Methods: Disc-shaped specimens with a diameter of 14.0 mm and thickness of 1.2 mm were milled from KATANA™ Zirconia YML and KATANA™ Zirconia UTML. Half of the YML specimens contained Enamel and body 1 layers, and half Body 2 and 3. UTML acted as control group. The groups were divided into 18 subgroups (n = 11) according to material/layers and finish treatment; laboratory polishing (P), glazing (G), laboratory polishing/glazing (PG), laboratory polishing/clinical adjustments by grinding/polishing (PC), glazing/clinical adjustments (GC), laboratory polishing/glazing/clinical adjustments (PGC). The specimens were subjected to thermocyclic-mechanical cyclic loading (10,000 cycles, 100 N, 5/55°C) and a biaxial flexural strength test. The surface roughness (Ra, Rz) was measured with a profilometer. Surface structure and elemental composition was evaluated with scanning electron microscopy and energy dispersive spectroscopy. The surface roughness and biaxial flexural strength were analysed with Three- and Two-way ANOVA, Tukey's test, with a significance level of α = 0.05.

Results: The flexural strength of the material/layers significantly decreased in the order Body 2-3, Enamel-body 1, and UTML. Body 2-3 had higher flexural strength after clinical adjustments and Enamel-body 1 and UTML lower. There was no difference between P, G and PG for Enamel-body 1. Body 2-3 showed highest flexural strength after polishing, followed by polishing and glazing, and glazing. UTML had highest strength after polishing and glazing or glazing alone. The surface roughness was generally lowest after polishing. The surface structure differed between the materials in as sintered stage regarding grain size and distribution but was similar after the finish treatments. The yttrium amount was highest in UTML, followed by Enamel-body 1, and Body 2-3.

Conclusions: The preferred laboratory finish treatment to promote the flexural strength and surface roughness of multilayer zirconia is dependent on the zirconia type but is more critical for zirconia with higher yttria content. Composition-gradient multilayer zirconia should be polished and shade-gradient multilayer zirconia with > 5 mol% yttria should be polished and glazed at the laboratory. Clinical adjustments significantly affect the flexural strength of multilayer zirconia depending on the zirconia type. For zirconia with higher yttria content, clinical adjustments have a detrimental effect on the flexural strength and should be performed with caution.

Place, publisher, year, edition, pages
Elsevier, 2025
National Category
Odontology
Identifiers
urn:nbn:se:mau:diva-87323 (URN)10.1016/j.dental.2025.03.070 (DOI)
Available from: 2026-07-30 Created: 2026-07-30 Last updated: 2026-07-30Bibliographically approved
Vervack, V., Johansson, C., Coster, P. D., Fokkinga, W., Papia, E. & Vandeweghe, S. (2024). The fracture strength and the failure mode of lithium disilicate or resin nano ceramics as a crown, overlay, or endocrown restoration on endodontically treated teeth. Journal of Esthetic and Restorative Dentistry, 36(5), 796-803
Open this publication in new window or tab >>The fracture strength and the failure mode of lithium disilicate or resin nano ceramics as a crown, overlay, or endocrown restoration on endodontically treated teeth
Show others...
2024 (English)In: Journal of Esthetic and Restorative Dentistry, ISSN 1496-4155, E-ISSN 1708-8240, Vol. 36, no 5, p. 796-803Article in journal (Refereed) Published
Abstract [en]

Introduction

Different materials and restorative concepts have been proposed over the years to restore endodontically treated teeth (ETT). Monolithic ceramic and composite restoration can be lute to the tooh, without the use of a post. However, little is known how the material stiffness and presence of a composite core will affect the survival and failure mode.

The objective of this in-vitro study was to evaluate the fracture strength and failure mode of endodontically treated molars, restored with ceramic or hybrid composite monolithic restoration, in the presence of absence of a composite core.

Materials and Methods

Sixty depulped molars were restored with a lithium-disilicate (e.max CAD) or hybrid composite (Cerasmart) restoration. Both materials were used in a monolithic approach, but with 3 different designs: (a) monolithic endocrown, (b) crown with a separate composite core, and (c) overlay without core buildup or pulpal extension. Ten sound teeth were used as control group. All groups were thermocycled (10,000 cycles), subsequently loaded in a chewing simulator (100,000 cycles) and finally loaded until fracture.

Results

Peak fracture loads and failure modes were registered. No significant differences were seen between the groups in terms of fracture load. Failure modes were statistically significantly different among groups with significant correlation between restoration type and material. (p < 0.001 and p = 0.033, respectively). No group presented significantly higher fracture resistance. Although ceramic crowns and overlays presented the highest repairability, all restored ETT were within the range of the intact tooth' fracture strength.

Conclusion

No restoration presented significant different fracture loads. However, the type of restoration and material choice were correlated to the fracture mode.

Place, publisher, year, edition, pages
John Wiley & Sons, 2024
Keywords
digital workflow, lithium disilicate, resin nano ceramic, hybrid composite, short fiber-reinforced composite, endocrown, full coverage crown, overlay
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-64813 (URN)10.1111/jerd.13187 (DOI)001133338400001 ()38152852 (PubMedID)2-s2.0-85180870909 (Scopus ID)
Available from: 2024-01-02 Created: 2024-01-02 Last updated: 2024-05-21Bibliographically approved
Johansson, C., Franco Tabares, S., Larsson, C. & Papia, E. (2023). Laboratory, Clinical-Related Processing and Time-Related Factors’ Effect on Properties of High Translucent Zirconium Dioxide Ceramics Intended for Monolithic Restorations A Systematic Review. Ceramics, 6(1), 734-797
Open this publication in new window or tab >>Laboratory, Clinical-Related Processing and Time-Related Factors’ Effect on Properties of High Translucent Zirconium Dioxide Ceramics Intended for Monolithic Restorations A Systematic Review
2023 (English)In: Ceramics, E-ISSN 2571-6131, Vol. 6, no 1, p. 734-797Article, review/survey (Refereed) Published
Abstract [en]

Because new zirconia materials are constantly being developed, the aim was to identify and qualitatively synthesize research on how processing and time-related factors affect the properties of high translucent (HT) zirconia intended for monolithic restorations. Cochrane Library, PubMed, Scopus, Web of Science, and reference lists were searched for in vitro and clinical studies. Eligibility and risk of bias were assessed. A synthesis of 142 publications was performed. HT 3Y-TZP was the most common, followed by 5YSZ, 4YSZ, and multilayer. In the laboratory, HT 3Y-TZP should be sintered according to the manufacturer’s recommendation and polished before glazing to favour strength, roughness, and wear behaviour. In the clinic, polishing is necessary after grinding to favour roughness and aging resistance. Over time, when using hydrothermal aging, t–m phase transformation and reduced translucency are expected, without affecting the strength and roughness. The strength of 4YSZ and 5YSZ is unaffected. However, the time-related methods are of questionable clinical significance. The evidence of all other factors’ effects on the properties of HT zirconia is lacking or limited; thus, these factors are of relevance for future research. There is a high heterogeneity of study designs and methods, and the results are brand-dependent.

Place, publisher, year, edition, pages
MDPI, 2023
Keywords
aging; clinic, crystalline phase, dental laboratory, glazing, flexural strength, manufacturing, material properties, mechanical properties, monolithic restorations, optical properties, physicochemical properties, polishing, processing factors, sintering, surface properties, translucency, Y-TZP, YSZ, zirconia, zirconium dioxide
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-58774 (URN)10.3390/ceramics6010045 (DOI)000953782100001 ()2-s2.0-85151156998 (Scopus ID)
Available from: 2023-03-23 Created: 2023-03-23 Last updated: 2026-10-01Bibliographically approved
Johansson, C., Dibes, J., Rodriguez, L. E. & Papia, E. (2021). Accuracy of 3D printed polymers intended for models and surgical guides printed with two different 3D printers. Dental materials journal, 40(2), 339-347
Open this publication in new window or tab >>Accuracy of 3D printed polymers intended for models and surgical guides printed with two different 3D printers
2021 (English)In: Dental materials journal, ISSN 0287-4547, Vol. 40, no 2, p. 339-347Article in journal (Refereed) Published
Abstract [en]

, NextDent™ Model, NextDent™ SG, and two designs; models A and B (n=5), were manufactured (DDDP, EvoDent). Trueness was evaluated by comparing values for 26 parameters with the CAD models' reference values and precision through standard deviation. The trueness and precision were higher for linear than for angle parameters. X- and Y-axes showed higher trueness than Z-axis and model B higher trueness than model A. The conclusions are; the accuracy is dependent on the design of the object. The linear precision appears to be high. The highest trueness was observed for a surgical guide polymer (NextDent™ SG). The definition of clinically relevant accuracy and acceptable production tolerance should be evaluated in future studies.

Place, publisher, year, edition, pages
The Japanese Society for Dental Materials and Devices, 2021
Keywords
3D printing, Additive manufacturing, Dental models, Digital light processing, Surgical guides
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-36778 (URN)10.4012/dmj.2020-039 (DOI)000656905800010 ()33100299 (PubMedID)2-s2.0-85103683470 (Scopus ID)
Available from: 2020-11-11 Created: 2020-11-11 Last updated: 2025-01-14Bibliographically approved
Johansson, C., Håkansson, A. & Papia, E. (2021). Bond strength between titanium and polymer-based materials adhesively cemented. Biomaterial Investigations in Dentistry, 8(1), 79-86
Open this publication in new window or tab >>Bond strength between titanium and polymer-based materials adhesively cemented
2021 (English)In: Biomaterial Investigations in Dentistry, E-ISSN 2641-5275, Vol. 8, no 1, p. 79-86Article in journal (Refereed) Published
Abstract [en]

The aim was to evaluate the bond strength between titanium and polymer-based materials for prosthetic restorations, cemented with different adhesive cement systems. Eight groups with 13 specimens in each group were included. Each specimen consisted of two parts: a cylinder of titanium resembling a titanium base, and a cylinder of one of two polymer-based materials Micro Filled Hybrid (MFH) or Telio CAD and cemented with one of four adhesive cement systems, namely Multilink Hybrid Abutment, Panavia V5, RelyX Ultimate and G-Cem LinkAce. The titanium was sandblasted with 50 µm Al2O3 and treated according to each cement manufacturer's recommendations. The polymer-based materials were pre-treated according to the manufacturer's instructions including sandblasting for MFH. After cementation, the groups were water stored for one day before thermocycling: 5000 cycles in 5–55 °C. A shear bond strength test was performed (crosshead speed 0.5 mm/min) and data was analysed with one-way ANOVA, Tukey's test. Telio CAD cemented with Panavia V5 and G-Cem LinkAce showed significantly lower bond strength compared to all other groups, due to spontaneous debonding. The highest numerical bond strength was found in the group of MFH cemented with RelyX Ultimate or with G-Cem LinkAce. Generally, the Telio CAD groups showed lower bond strength values than the MFH groups. The conclusions are that pre-treatment methods and choice of cement system are of importance for polymer-based materials for prosthetic restorations. The bond strength is adequate for provisional cementation irrespective of cement system when pre-treating by sandblasting, but cement dependent without sandblasting.

Place, publisher, year, edition, pages
Taylor & Francis, 2021
Keywords
Adhesive cementation, bond strength, polymer-based materials, titanium base implant-supported dental prosthesis
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-51419 (URN)10.1080/26415275.2021.1937182 (DOI)34212155 (PubMedID)2-s2.0-85123935232 (Scopus ID)
Available from: 2022-05-11 Created: 2022-05-11 Last updated: 2024-12-01Bibliographically approved
Johansson, C. & Vult von Steyern, P. (2019). Porslin och glaskeramer - våra mest estetiska material. Den norske tannlegeforenings tidende, 130(1), 14-19
Open this publication in new window or tab >>Porslin och glaskeramer - våra mest estetiska material
2019 (English)In: Den norske tannlegeforenings tidende, ISSN 0029-2303, E-ISSN 1894-180X, Vol. 130, no 1, p. 14-19Article in journal (Refereed) Published
Abstract [sv]

Porsliner är de dentala material som har störst potential att ur ett estetiskt perspektiv efterlikna naturlig tandsubstans. Genom att tandersättningar av porslin framställs med skiktningsteknik finns det möjlighet att styra de optiska egenskaperna såsom translucens, opalescens och fluorescens. Den goda estetiken kommer däremot till priset av att materialets höga glashalt leder till relativt låg hållfasthet och därmed begränsade indikationsområden.

Glaskeramer har högre hållfasthet och brottseghet - två viktiga egenskaper - men liknande optiska egenskaper som porslin och kan därmed användas antingen monolitiskt (med ett och samma material genom hela konstruktionen) med målningsteknik eller i kombination med ett ytporslin för att ytterligare förbättra estetiken (så kallad cut-back-teknik). De idag vanligast förekommande glaskeramerna är leucit- respektive litiumdisilikat-baserade samt de relativt nya zirkoniaförstärkta litiumsilikat-materialen (ZLS).

Indikationsområdet för porslin och glaskeramer är bland annat beroende av materialens egenskaper såsom böjhållfasthet, brottseghet och optiska egenskaper. Framställningsteknik, om ersättningen är monolitiskt utformad eller skiktad med ytporslin och hanteringen av materialet påverkar den slutliga ersättningens hållfasthet, vilken även är avhängig av val av cement, cementeringsteknik och tillgång till perifer emalj.

Place, publisher, year, edition, pages
Fabritius Soenner A S, 2019
National Category
Odontology
Identifiers
urn:nbn:se:mau:diva-80592 (URN)10.56373/2019-1-4 (DOI)
Available from: 2025-11-12 Created: 2025-11-12 Last updated: 2025-11-12Bibliographically approved
Johansson, C., Kmet, G., Rivera, J., Larsson, C. & Vult von Steyern, P. (2014). Fracture strength of monolithic all-ceramic crowns made of high translucent yttrium oxide-stabilized zirconium dioxide compared to porcelain-veneered crowns and lithium disilicate crowns (ed.). Acta Odontologica Scandinavica, 72(2), 145-153
Open this publication in new window or tab >>Fracture strength of monolithic all-ceramic crowns made of high translucent yttrium oxide-stabilized zirconium dioxide compared to porcelain-veneered crowns and lithium disilicate crowns
Show others...
2014 (English)In: Acta Odontologica Scandinavica, ISSN 0001-6357, E-ISSN 1502-3850, Vol. 72, no 2, p. 145-153Article in journal (Refereed) Published
Abstract [en]

Abstract Objective. The aim of the study was to provide data on the fracture strength of monolithic high translucent Y-TZP crowns and porcelain-veneered high translucent Y-TZP crown cores and to compare that data with the fracture strength of porcelain-veneered Y-TZP crown cores and monolithic lithium disilicate glass-ceramic crowns. Materials and methods. Sixty standardized crowns divided into six groups (n = 10) were fabricated: monolithic high translucent Y-TZP crowns, brand A, monolithic high translucent Y-TZP crowns, brand B, veneered high translucent Y-TZP crown cores, brand A, veneered high translucent Y-TZP crown cores, brand B, heat-pressed monolithic lithium disilicate crowns and veneered Y-TZP crown cores. All crowns were thermocycled, cemented onto dies, cyclically pre-loaded and finally loaded to fracture. Results. The monolithic Y-TZP groups showed significantly higher fracture strength (2795 N and 3038 N) compared to all other groups. The fracture strength in the veneered Y-TZP group (2229 N) was significantly higher than the monolithic lithium disilicate group (1856 N) and the veneered high translucent Y-TZP groups (1480 N and 1808 N). Conclusions. The fracture strength of monolithic high translucent Y-TZP crowns is considerably higher than that of porcelain-veneered Y-TZP crown cores, porcelain-veneered high translucent Y-TZP crown cores and monolithic lithium disilicate crowns. The fracture strength of a crown made of monolithic high translucent Y-TZP is, with a large safety margin, sufficient for clinical use for the majority of patients. Porcelain-veneered Y-TZP crown cores show higher fracture resistance than monolithic lithium disilicate crowns.

Place, publisher, year, edition, pages
Taylor & Francis, 2014
Keywords
Dental ceramics, glass ceramics, oxide ceramics, Y-TZP, zirconia
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-6893 (URN)10.3109/00016357.2013.822098 (DOI)000333047000009 ()23865549 (PubMedID)2-s2.0-84892951317 (Scopus ID)16339 (Local ID)16339 (Archive number)16339 (OAI)
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-02-05Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0001-6693-8278

Search in DiVA

Show all publications