Malmö University Publications
Change search
Link to record
Permanent link

Direct link
Ameri, Arman
Publications (2 of 2) Show all publications
Segerström, S., Wiking-Lima de Faria, J., Braian, M., Ameri, A. & Ahlgren, C. (2019). A Validation Study of the Impression Replica Technique. (ed.). Journal of Prosthodontics, 28(2), e609-e616
Open this publication in new window or tab >>A Validation Study of the Impression Replica Technique.
Show others...
2019 (English)In: Journal of Prosthodontics, ISSN 1059-941X, E-ISSN 1532-849X, Vol. 28, no 2, p. e609-e616Article in journal (Refereed) Published
Abstract [en]

PURPOSE: To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. MATERIALS AND METHODS: The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. RESULTS: The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 mum. CONCLUSION: The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry.

Place, publisher, year, edition, pages
John Wiley & Sons, 2019
Keywords
Internal gap, marginal gap, misfit, production tolerance
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-6937 (URN)10.1111/jopr.12795 (DOI)000458904300043 ()29664193 (PubMedID)2-s2.0-85045757643 (Scopus ID)26706 (Local ID)26706 (Archive number)26706 (OAI)
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-02-05Bibliographically approved
Lindström, M. J., Ahmad, M., Jimbo, R., Ameri, A., Vult von Steyern, P. & Becktor, J. P. (2019). Volumetric measurement of dentoalveolar defects by means of intraoral 3D scanner and gravimetric model (ed.). Odontology: official journal of The Society of the Nippon Dental University, 103(3), 353-359
Open this publication in new window or tab >>Volumetric measurement of dentoalveolar defects by means of intraoral 3D scanner and gravimetric model
Show others...
2019 (English)In: Odontology: official journal of The Society of the Nippon Dental University, ISSN 1618-1247, E-ISSN 1618-1255, Vol. 103, no 3, p. 353-359Article in journal (Refereed) Published
Abstract [en]

The aim of this study was to evaluate the accuracy in volumetric measurements obtained on an experimental model using an intraoral scanner and a gravimetric method. Three identical partial dentate maxillary acrylic models with three fabricated alveolar defects, in anterior and posterior regions, were scanned using an intraoral scanner (20 scans/defects). The defects differed in terms of size and distance of neighbouring teeth. As references, replicas of each defect were created using a dimensional stable silicone impression material. After measuring the mass of each replica, the volume was calculated by dividing the mass of each replica by the density of the impression material. The defects had a volume, according to the gravimetric method, ranging from 40.5 to 143.7 mm. The scans were imported to metrology software for analyses. Accuracy was determined in terms of trueness and precision. The mean trueness for all defect types was 0.168 mm (SD 0.691, range 2.82). There was no statistical significant difference between the mean trueness for all defects measured (p = 0.910). The mean precision for all defect types was 0.147 mm (SD 0.524, range 2.86). There were no statistical significant differences between the dental models in regard to mean precision (p = 0.401), however, there were statistical significant differences between defects in position 1 and 2 (p = 0.002) and 1 and 3 (p = 0.001). Based on the findings of this study, the intraoral scanner utilized in the current study presented an acceptable level of accuracy when measuring volume of defects.

Place, publisher, year, edition, pages
Springer, 2019
Keywords
Intraoral scanning, Surgical techniques, Tissue alterations, Volumetric measurement, Wound healing
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-15492 (URN)10.1007/s10266-018-00410-6 (DOI)000471055600010 ()30617638 (PubMedID)2-s2.0-85059638061 (Scopus ID)27875 (Local ID)27875 (Archive number)27875 (OAI)
Available from: 2020-03-30 Created: 2020-03-30 Last updated: 2026-10-12Bibliographically approved
Organisations

Search in DiVA

Show all publications