Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effect of Blood Lactate Sample Site and Test Protocol on Training Zone Prescription in Rowing
English Institute of Sport, Gateshead, U.K..ORCID iD: 0009-0002-7460-562X
Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, U.K..
2008 (English)In: International Journal of Sports Physiology and Performance, ISSN 1555-0265, E-ISSN 1555-0273, Vol. 3, no 3, p. 347-358Article in journal (Refereed) Published
Abstract [en]

Purpose:To assess the effect of sample site (earlobe vs toe) and incremental exercise protocol (continuous vs discontinuous) on training zone prescription in rowing.Methods:Twenty-six rowers performed two incremental exercise tests on an ergometer: (1) a five-step discontinuous test with 4-min stages and 30-W increment, with blood samples taken from the earlobe and toe at the start of the 1-min break between steps; (2) a continuous test, with 2-min stages and 30-W increment, with blood samples taken from the right first toe at the end of each stage. Blood was analyzed for lactate concentration.Results:At a lactate concentration of 2 mmol·L−1, the mean (95% CI) power output was 8.1 (± 15.4) W greater for the continuous protocol, the random error between the methods (1.96 × SD of differences) was ± 58.8 W, and there was no evidence of any relationship between power output and error between methods. At a lactate concentration of 4 mmol·L−1, the mean (95% CI) power output was 24.2 (± 17.0) W greater for the continuous protocol, and the random error was ± 64.8 W. At 4 mmol·L−1, systematic bias between methods increased with high power outputs.Conclusions:The continuous protocol with toe sampling led to higher power outputs for a given lactate concentration compared with the discontinuous protocol with earlobe sampling. This was partly due to the choice of sample site and largely due to the choice of protocol. This bias, and also random variability, makes direct comparison of these tests inappropriate.

Place, publisher, year, edition, pages
2008. Vol. 3, no 3, p. 347-358
National Category
Sport and Fitness Sciences
Identifiers
URN: urn:nbn:se:mau:diva-67164DOI: 10.1123/ijspp.3.3.347ISI: 000207535900009PubMedID: 19211946Scopus ID: 2-s2.0-57749173668OAI: oai:DiVA.org:mau-67164DiVA, id: diva2:1856823
Available from: 2024-05-08 Created: 2024-05-08 Last updated: 2025-02-11Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Garland, Stephen

Search in DiVA

By author/editor
Garland, Stephen
In the same journal
International Journal of Sports Physiology and Performance
Sport and Fitness Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 30 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf