Validering av ny och äldre spirometriapparatur
Malmö University, Faculty of Health and Society (HS).
2018 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Förekommande abnormiteter i luftvägarna eller i lungorna är en frekvent orsakande faktor till störningar i ventilationsförmågan. Förekomsten av avvikelser från det normala i luftvägarna eller i lungorna kan påtagligt medföra tilltäppande/hindrande av luftflödet i luftvägarna men även resultera i begränsning av lungkapaciteten. För konkret bedömning av andningsmekanismens funktion krävs relevant nyckelinformation för utvärdering av andningskapaciteten. Vid misstanke om respirationsstörningar eller påvisande av andningsrelaterade symtom utförs en grundläggande lungfunktionsmätning, så kallad spirometriundersökning. Det förekommer två typer av spirometri: statisk och dynamisk, vilket innebär mätning av in- och utandade volymer samt luftflöde, och utgör grunden beträffande lungornas funktion. Spirometri är en undersökningsmetod i syfte att mäta lungornas kapacitet men är även det väsentligaste verktyget vid utredning att ställa diagnos vid misstänkt obstruktiv/restriktiv lungsjukdom, strukturella skador samt högt sittande andningshinder. På grund av tilltagande efterfrågan har spirometrikapaciteten på Skånes universitetssjukhus (SUS) i Lund utökats och två nya system införskaffats för att ersätta den befintliga. Då kliniken handhåller ett ackrediteringsbevis önskades följaktligen en jämförelseanalys. Studien innefattade 13 deltagare, och syftet var att dels jämföra ny och äldre spirometriapparatur, och dels att jämföra eventuella skillnader mellan ny spirometriapparatur. Beträffande de lungvolymer som jämfördes (TLC, RV, FRC, VC, FEV_1,0 och DLCO) visade resultatet att skillnaderna mellan de olika mätenheterna bedöms som generellt små, huvudsakligen inte större än vad som faller inom mätosäkerheten och är kliniskt acceptabla.

Abstract [en]

Occurring abnormalities in the airways or in the lungs are a frequent causative factor for disruptions in the ventilation ability. The occurrence of abnormalities different from the normal state in airways or in lungs can significantly lead to obstruction of air supply in the airways but also result in limitation of the lung capacity. For concrete assessment of the breathing mechanism function, relevant key information is needed for evaluation of the breathing capacity. In case of suspicion of respiratory disturbances or detection of breathing related symptoms, a basic lung function measurement is made, also called spirometry examination. There are two types of spirometry: static and dynamic, which means measurements of inhaled and exhaled volumes and air flow, and it constitutes the ground for the function of the lungs. Spirometry is an examination method in purpose of measuring the capacity of the lungs but is also the essential tool when a medical work-up is made to set the diagnosis on a suspected obstructive /restrictive pulmonary disease, structural damages and high sitting breathing difficulties. Because of the increasing demands, the spirometry capacity in Skånes universitetsjukhus (SUS) in Lund has expanded and two new systems have been acquired to replace the existing one. Since the clinic possesses an accreditation certificate a comparison analysis was desired. The study included 13 participants, and the purpose was partly to compare new and elderly spirometry apparatus, and partly to compare eventual differences between new spirometry apparatus. Regarding the lung volumes that was compared (TLC, RV, FRC, VC, FEV_1,0 and DLCO) the results showed that the differences between the different measuring units is estimated generally small, mainly not bigger than what falls within the measurement uncertainty and is clinical acceptable.

Place, publisher, year, edition, pages
Malmö universitet/Hälsa och samhälle , 2018. , p. 28
Keywords [sv]
Dynamiska lungvolymer, Jämförelseanalys, Lungfunktionsmätning, Lungvolymer, Spirometri, Statiska lungvolymer
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-25324Local ID: 25669OAI: oai:DiVA.org:mau-25324DiVA, id: diva2:1486833
Educational program
HS Biomedicinsk laboratorievetenskap
Supervisors
Examiners
Available from: 2020-11-03 Created: 2020-11-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Faculty of Health and Society (HS)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 56 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf