Inverkan av omgivande klimatets temperaturförändringar på mätresultat vid fuktmätning i betong
Malmö University, Faculty of Technology and Society (TS).
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

I detta examensarbete som utfördes under vårterminen 2019 på Malmö universitet undersöktes hur temperaturförändringar i det omgivande klimatet påverkar mätresultat vid fuktmätningar i betong. Vid fuktmätningar i betong, i fält, används metoden borrhålsmätning. Vid borrhålsmätningar borras ett hål i en betongplatta eller ett betongbjälklag, därefter monteras ett mätrör i hålet sedan monteras en fuktgivare. Detta görs vanligtvis enligt RBK-systemets, Manual – Fuktmätning i betong. För att undersöka hur temperaturförändringar i det omgivande klimatet påverkar mätresultatet vid fuktmätningar utfördes försök där en provkropp gjöts med bascement, vct 0,38. Åtta termistorer gjöts in på olika djup för att kunna logga temperaturen på olika djup i provkroppen vid en temperaturförändring i det omgivande klimatet, dessa mätvärden jämfördes sedan med den loggade temperaturen samt de loggade RF-värdena från fuktgivaren. Fuktgivaren som användes vid försöken var Vaisala HMP110. För att utföra kontrollerade temperaturförändringar utfördes försöken i en fuktgenerator. Tre huvudförsök utfördes, ett med en momentan temperaturförändring i det omgivande klimatet, ett med en långsam temperaturförändring i det omgivande klimatet samt ett där okontrollerade temperaturförändringar i det omgivande klimatet skedde. Resultaten från dessa försök visar att när en temperaturförändring i det omgivande klimatet sker mäter fuktgivarens temperatursensor betongens faktiska temperatur med god noggrannhet, men ett felaktigt RF-värde kommer att ges om en avläsning av mätvärdet sker innan en ny temperaturjämvikt har etablerats. Resultaten visar även att vid omräkning av RF till RF vid 20°C, enligt RBK-systemet, förvärras mätfelet när temperaturen inte är stabil i det omgivande klimatet.

Abstract [en]

In this bachelor thesis a study is done to see how ambient climate changes impacts the measurement results during moisture measurements in concrete. The method of measurement used is borehole measurements according to the RBK-system, Manual – Fuktmätning i betong. The experiments were conducted in a laboratory environment on a concrete slab, which was casted with bascement and had a w/c ratio of 0,38. To see how well the moisture meter performed during ambient climate changes eight thermistors were cast into the concrete slab to log the temperature at different depths of the concrete during the ambient climate changes. The results show that the moisture meter does read the actual temperature of the concrete during an ambient climate change, however the ambient climate change had an impact on the measurement results of the relative humidity (RH). If a snapshot measurement of the RH is done after a temperature change in the ambient climate, an incorrect measurement result of the RH is obtained. When the obtained RH is converted to RH at 20°C the fault will get enlarged. To obtain a correct RH measurement when a field measurement is done, a logged measurement should be conducted.

Place, publisher, year, edition, pages
Malmö universitet/Teknik och samhälle , 2019. , p. 31
Keywords [sv]
Fukt, Fuktmätning, Betong, Moisture, Concrete, Klimat, Ambient, Climate, Temperaturförändringar
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:mau:diva-20297Local ID: 29630OAI: oai:DiVA.org:mau-20297DiVA, id: diva2:1480171
Educational program
TS Byggingenjör
Supervisors
Examiners
Available from: 2020-10-27 Created: 2020-10-27Bibliographically approved

Open Access in DiVA

fulltext(1363 kB)160 downloads
File information
File name FULLTEXT01.pdfFile size 1363 kBChecksum SHA-512
75fbef7bbfaf5828e3a91d7642480b51b6ec7903d6f8436c9a3af2d41fefe6aba800d352919596226ba920bab29d3868430b95f63929cd77d56f0bda536324c6
Type fulltextMimetype application/pdf

By organisation
Faculty of Technology and Society (TS)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 160 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 357 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf