Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Morphological and Morphometric Comparison of Interface in Original Abutment and Copy Compatible Abutment Connected to Original Implant
Malmö högskola, Faculty of Odontology (OD).
Malmö högskola, Faculty of Odontology (OD).
2016 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

I nuläget finns flertalet företag som tillverkar distanser som är kompatibla med originalimplantat. Det finns dock ingen evidens för att dessa distanser är likvärdiga med originaldistanser när de används på originalimplantat. God passform hos implantatkomponenter är en viktig faktor för att undvika biologiska och tekniska komplikationer. Syftet med den här studien var att jämföra passformen mellan originaldistans och originlimplantat med kompatibel kopiadistans och originalimplantat. Material och metod: Fem originaldistanser och fem kompatibla distanser skruvades till originalimplantat. Provkroppar bäddades in och delade på mitten för att sedan analyseras i ljusmikroskop och SEM. Där mättes kontaktytans längd och mellanrummet mellan implantat och distans och distans och distansskruv. All data analyserades i SPSS. Resultatet: Implantatkoplex med kopiadistans hade fem gånger kortare kontaktyta mellan komponenterna och mellanrummet var större, vilket ger en försämrad stabilitet under andvändning. Analysen av distansskruvens yta visade morfologiska skillnader mot den inre ytan av distansen vilket kan leda till deformation och/eller fraktur av skruven. Konklusion: Användning av lågpris kopiadistanser till Astra originalimplantat kan leda till signifikant avvikande passform hos distansen och en lägre tolerans för stress hos distansskruven.

Abstract [en]

Nowadays there exist different abutments from different companies that are compatible to a certain manufacturer implant. But no scientific evidence exists on whether the fit of the compatible abutments are comparable to that of the genuine abutments when connected to the genuine implants. God fitting of implant components is an essential factor to avoid microgap formation in implant-abutment interface due to microgaps lead to biological and biomechanical complications. The aim of this study was to compare interface in original abutment and copy compatible abutment connected to original implant. Material and Methods: Five original abutments and five compatible abutments were connected to the original implants. The complex were sectioned in the middle and thereafter analyzed in a light microscope and SEM by measuring contact length and interface thickness between the implant and abutment and also between the abutment and abutment screw. All data was analyzed with SPSS-program. Result: Compatible implant complex had about five times shorter contact surface between components and interface was thicker which gives less stability under clinical function. The analyze of screw-abutment interface showed morphologic differences with the inner surface of the abutment which could lead to screw deformation and even fracture. Conclusion: Using low-cost compatible abutments connected to original Astra implants could lead to significant fit discrepancy of the copy abutments and lower stress tolerance in the abutment screw.

Place, publisher, year, edition, pages
Malmö högskola/Odontologiska fakulteten , 2016. , p. 14
Keywords [en]
Implant, Abutment, copy, original, Astra Tech, Abutment screw, Interface
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-19911Local ID: 20757OAI: oai:DiVA.org:mau-19911DiVA, id: diva2:1479756
Educational program
OD Tandläkarutbildning
Available from: 2020-10-27 Created: 2020-10-27 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

fulltext(160 kB)54 downloads
File information
File name FULLTEXT01.pdfFile size 160 kBChecksum SHA-512
0f285980e500d0fcc2eb454c8352d59dc497dcd542b790d2488105c7cb313e335fe7057394cf23d8a34598ac7e008b026f81ce4400bb307bd5d47e49cba389ba
Type fulltextMimetype application/pdf

By organisation
Faculty of Odontology (OD)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 54 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 82 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf