Malmö University Publications
Planned maintenance
A system upgrade is planned for 10/12-2024, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
LED-lampors härdningseffekt på komposit - En laborativ studie
Malmö University, Faculty of Odontology (OD).
Malmö University, Faculty of Odontology (OD).
2019 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Syfte: Att undersöka och jämföra effekten av olika LED-lampor genom mätning av konversionsgrad, härdningsdjup och mikro-hårdhet på en universal nano-komposit. Detta utifrån frågeställningarna: - Stämmer härdningslampornas verkliga irradians överens med den som uppges i produktdatabladen? - Kan härdningsprocessen effektiviseras genom att ljushärda med högre irradians och kortare härdningstid? Material & Metod: Materialegenskaperna - konversionsgrad, härdningsdjup och mikro-hårdhet mättes för kompositen Filtek Supreme XTE (3M ESPE) med fem LED-härdningslampor och olika härdningstider (kort, medellång, lång tid). LED-lamporna som användes i studien var L.E.Demetron II (Kerr), Mini LED (Satelec), D-Light Pro (GC), Epilar Deepcure-S (3M ESPE) och Flashmax P3 (CMS Dental). LED-lampornas spektralfördelning erhölls med en CCD-spektrometer (Avantes Inc.) kopplad till en integrerande sfär (Gooch & Housego) med en fiberoptisk kabel (Avantes Inc.). Data analyserades med ensidig och tvåsidig variansanalys (ANOVA-test) följt av Tukey-test. Resultat: En kort härdningstid och en härdning med låg irradians gav en lägre konversionsgrad, härdningsdjup och mikro-hårdhet jämfört med härdning med längre tid och hög irradians. Slutsats: Härdningslampornas verkliga irradians överensstämmer med irradiansen som uppges i produktdatabladen. En tillräcklig polymerisering uppnås med alla härdningslampor vid samtliga härdningstider. Härdningsprocessen kan effektiviseras och/eller förbättras genom att tillföra mer energi på kortare tid. Att förlänga härdningstiden utöver tillverkarens rekommendationer har en positiv effekt på materialegenskaperna – ökad konversionsgrad, härdningsdjup och mikro-hårdhet.

Abstract [en]

Aim: To investigate and compare the effect of different LED curing devices by measuring degree of conversion, curing depth and micro-hardness of a universal nanocomposite, based on the questions: - Does the actual irradiance of the curing lamps match the one specified in the product data sheets? - Can the curing process be done more efficiently by light curing with a higher irradiance and a shorter curing time? Materials & Methods: The material properties degree of conversion, curing depth and microhardness were measured for the Filtek Supreme XTE (3M ESPE) composite with different LEDs and after curing at different curing times (short, medium, long). The light curing units used in the study were L.E.Demetron II (Kerr), Mini LED (Satelec), D-Light Pro (GC), Epilar Deepcure-S (3M ESPE) and Flashmax P3 (CMS Dental). The spectral irradiance of the LEDs was obtained with a CCD spectrometer (Avantes Inc.) connected to an integral sphere (Gooch & Housego) with a fiber optic cable (Avantes Inc.). Data were analyzed with one- and two-way ANOVA test followed by Tukey test. Results: Short curing times and low irradiance results in lower values of the material properties compared to longer curing times and higher irradiance. Conclusion: The actual irradiance of the curing lamps is consistent with that stated in the product data sheets. Sufficient polymerization was achieved with all curing lamps at all curing times. The curing process can be made more efficient and/or be improved by adding more energy in less time. Extending the curing time has a positive effect on the material properties – an increased degree of conversion, depth of cure and micro-hardness.

Place, publisher, year, edition, pages
Malmö universitet/Odontologiska fakulteten , 2019. , p. 29
Keywords [sv]
Dental Composite, LED curing devices
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-19829Local ID: 29724OAI: oai:DiVA.org:mau-19829DiVA, id: diva2:1479674
External cooperation
Nordic Institute of Dental Materials (NIOM)
Educational program
OD Tandläkarutbildning
Supervisors
Examiners
Available from: 2020-10-27 Created: 2020-10-27 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

fulltext(1127 kB)458 downloads
File information
File name FULLTEXT01.pdfFile size 1127 kBChecksum SHA-512
36a7bc052a65064963532327ffa46f352ca33c412b4f5a225bad947f89bbdeb798961a234ad786e5f8fdaed21c9ed4bd9a0cbd5fe90934193e14947e6ced680f
Type fulltextMimetype application/pdf

By organisation
Faculty of Odontology (OD)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 462 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 86 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf