Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Is it possible to protect prosthetic reconstructions in patients with a prefabricated intraoral appliance? - A pilot study
Malmö högskola, Faculty of Odontology (OD).
Malmö högskola, Faculty of Odontology (OD).
2015 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Syfte: Att genom en klinisk pilotstudie undersöka huruvida det är möjligt att använda bettskenan Relax™ för att skydda fasta protetiska konstruktioner hos patienter. Målet var även att genom en enkätundersökning, kvalitativt studera patienternas personliga inställning och upplevelse med att skydda sina protetiska konstruktioner med en Relax™. Material och metod: Tolv patienter med fasta protetiska konstruktioner utförda på Odontologiska fakulteten, Malmö högskola under perioden 2013-2014 valdes slumpmässigt in i en testgrupp och en kontrollgrupp med sex patienter vardera. Patienter i testgruppen fick en individuellt anpassad Relax™ skena för användning under en 6 månaders period i syfte att skydda sina nya protetiska konstruktioner. Vid två tillfällen, baseline samt 6-månaders uppföljning bedömdes de protetiska konstruktionernas kliniska kvalitet hos patienter i både test och kontroll grupp med hjälp av en modifierad version av California Dental Association (CDA) utvärderingssystem. Test och kontrollgruppen genomgick även en DC/TMD undersökning för att utröna eventuella parafunktioner, orofacial smärta eller TMD. För att inhämta kvalitativ information fick test samt kontrollgrupp fylla i en enkät vid baseline. Vid uppföljningen efter 6 månader fick patienterna i testgruppen en slutlig enkät för att utvärdera sina upplevelser efter användning med en Relax™ för att skydda sina protetiska konstruktioner. Resultat: Vid baseline värderades samtliga protetiska konstruktioner hos patienterna i både test samt kontrollgrupp till Romeo som motsvarar hög klinisk kvalitet enligt CDA utvärderingen. Vid uppföljning efter 6 månader visade två protetiska konstruktioner hos två patienter i kontrollgruppen tecken på porslins chip-off på ocklusal ytorna. Dessa var samma patienter med rapporterade bruxism vanor enligt DC/TMD undersökningen. En majoritet av patienterna i testgruppen som fick diagnosen myalgi eller artralgi vid första tillfället uppvisade inga symptom vid uppföljningen efter test perioden med en Relax ™. Konklusion: Resultaten stödjer hypotesen att Relax ™ möjligen kan ha en skyddande effekt på den fasta protetiska rekonstruktionen i de fall där patienter har en parafunktion såsom bruxism. Relax ™ var effektiv vid behandling av patienter som diagnosticerades med myalgi och artralgi. Majoritet av patienterna visade ett intresse för en ökad livslängd och hållbarhet av deras nya protetiska rekonstruktioner. I testgruppen observerades en mer positiv attityd avseende att vilja skydda framtida protetiska rekonstruktioner. Det vore önskvärt med en större studie med långtidsuppföljning samt bredare patientunderlag Det finns ett behov av framtida kliniska studier utav hög kvalitet för att stödja eventuellt samband mellan slitage och konsekvensern hos protetiska rekonstruktioner då det finns få belägg som bevisar fördelarna med en skyddande bettskena.

Abstract [en]

The aim of this pilot study was evaluating the effect of wearing Relax™ to protect newly received fixed prosthetic reconstructions in patients. Furthermore, it aimed to study the patient’s general attitude and experience towards using Relax™ as a protective appliance. Twelve patients with newly received fixed prosthodontics were randomly selected into a test group and a control group with six patients in each group during the period 2013-2014 at the faculty of Odontology. Patients in the test group received a individually adjusted Relax™ to use for a period of six months. Both test and control group underwent at two occasions, baseline and follow-up a DC/TMD examination in order to evaluate any parafunctions, orofacial pain or TMD. Clinical evaluations of the prosthetic reconstructions of the patients in test and control group were made using a modified version of California Dental Association (CDA) evaluation system. CDA was used to verify any difference of the clinical quality of the prosthetic reconstruction at baseline and follow-up after six months. The patients in the test and control group were given a questionnaire at baseline in order to retrieve qualitative information about their opinions in protecting their new prosthetic reconstructions. A final questionnaire was given only to the patients in the test group to evaluate their experience in using Relax™ as a protective appliance. The Results at baseline was that all of the prosthetic reconstructions in test and control group were evaluated to Romeo, equivalent to a rate of highest quality according to the CDA evaluation. At follow-up after 6 months two of the constructions in two patients in the control group were showing signs of porcelain chip offs at the occlusal surface. These were the same patients with a reported bruxism behavior according to DC/TMD examination. A majority of the patients in test group diagnosed with myalgia or arthralgia at baseline were treated at follow-up with the use of Relax™. The results support the hypothesis that Relax™ might have a protective effect on the fixed prosthetic reconstruction in cases where patients have parafunction such as bruxism behavior. Relax™ was effective in treating patients with myalgia and arthralgia diagnoses. Majority of patients showed interest in the longevity and durability of their new prosthetic reconstructions. In the test group a more positive attitude was observed regarding protecting future prosthetic reconstructions. It should be taken into consideration that there is a need for a more long-term study with more patients to verify the results from this pilot study. A high quality clinical study is needful to support possible relationship between bruxism, wear and failure in prosthetic rehabilitation since no there are no scientific evidence available that demonstrates the benefits of a protective appliance.

Place, publisher, year, edition, pages
Malmö högskola/Odontologiska fakulteten , 2015. , p. 46
Keywords [en]
Prosthodontics, appliance, protection
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-19762Local ID: 18852OAI: oai:DiVA.org:mau-19762DiVA, id: diva2:1479606
Educational program
OD Tandläkarutbildning
Available from: 2020-10-27 Created: 2020-10-27 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Faculty of Odontology (OD)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 54 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf