Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Assessment of bone quantity and quality in CBCT-images prior to dental implant treatment
Malmö högskola, Faculty of Odontology (OD).
2014 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Bakgrund: Vid undersökning av käkarnas benvävnad inför implantatbehandling kan intraoral röntgen och panoramaröntgen behöva kompletteras med CBCT. Studier som utvärderar reliabiliteten av en CBCT-undersökning vid bedömning av käkarnas benkvantitet inkluderar få observatörer. Det är brist på studier som utvärderar reliabiliteten av en CBCT-undersökning vid bedömning av käkarnas benkvalitet. Syfte: Syftet var att undersöka hur observatörers bedömningar överensstämmer (reliabiliteten) när de bedömer käkarnas benkvantitet och benkvalitet i förvalda och subjektivt valda CBCT-bilder inför implantatbehandling. Material och metod: Patienter som remitterades för en CBCT-undersökning inför implantatbehandling inkluderades. Detta resulterade i ett konsekutivt urval av tolv undersökningar från överkäkens sidopartier, tolv från överkäkens front och tolv från underkäkens sidopartier. Fem observatörer bedömde benkvantitet genom att mäta benhöjden i millimeter och benkvalitet enligt klassificeringarna föreslagna av Lekholm & Zarb (1985) och Lindh och medarbetare (1996) i både förvalda och subjektivt valda CBCT-bilder. Tre observatörer repeterade sina bedömningar. Resultat: Observatörsöverensstämmelsen var hög vid bedömning av benkvantitet (ICC 0.86 – 1.0). Observatörsöverensstämmelsen var däremot låg till måttlig vid bedömning av benkvalitet (kappa 0.11 – 0.55). Observatörsöverensstämmelser var högre för både bedömning av benkvantitet och benkvalitet när bedömningarna utfördes i förvalda jämfört med subjektivt valda CBCT-bilder. Konklusion: Observatörsöverenstämmelsen representerar en övre gräns för tillförlitligheten. Således kan resultaten från denna studie tyda på att CBCT har en hög tillförlitlighet och därmed är en effektiv metod för bedömning av benkvantitet inför implantatbehandling. Resultaten på observatörsöverrensstämmelsen vid bedömning av käkarnas benkvalitet kan däremot tyda på att CBCT har en lägre tillförlitlighet och därmed kan vara en mindre effektiv metod för bedömning av benkvalitet inför implantatbehandling.

Abstract [en]

Background: Jaw bone tissue can be evaluated with CBCT prior to dental implant treatment. There is a lack of studies on observer performance when assessing bone quality and few observers are included when assessing bone quantity with CBCT. Objective: The aim was to assess observer performance when evaluating bone quantity and quality in CBCT-images prior to dental implant treatment. Methods: Patients, who were referred for a CBCT examination of the jaws prior to dental implant treatment, were included. Consecutive examinations were selected so that 12 examinations of each of the following regions were included: the maxillary posterior region, the maxillary anterior region and the mandibular posterior region. Five observers assessed the bone quantity, i.e. bone height in millimeters, and the bone quality according to the classifications proposed by Lekholm & Zarb (1985) and Lindh et al. (1996) in preselected and subjectively selected CBCT-images. Three observers repeated their assessments. Results: For assessment of bone quantity, observer agreement was high (ICC range 0.86 – 1.0). Observer agreement was low to moderate for assessment of bone quality (kappa range 0.11 – 0.55). The observer agreement for assessment of bone quantity and quality was higher when assessment was made in preselected compared to subjectively selected CBCT-images. Conclusion: Since observer performance represents a higher limit for the diagnostic accuracy efficacy, the results may indicate a high diagnostic accuracy efficacy of CBCT when evaluating bone quantity. Results on observer agreement for assessment of bone quality may indicate a limited diagnostic accuracy efficacy of CBCT when assessing bone quality according to the classifications used.

Place, publisher, year, edition, pages
Malmö högskola/Odontologiska fakulteten , 2014. , p. 52
Keywords [en]
Cone Beam Computed Tomography, Observer variation, Jawbone tissue
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:mau:diva-19610Local ID: 17085OAI: oai:DiVA.org:mau-19610DiVA, id: diva2:1479454
Educational program
OD Tandläkarutbildning
Available from: 2020-10-27 Created: 2020-10-27 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Faculty of Odontology (OD)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 46 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf