Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw
Malmö högskola, Faculty of Odontology (OD).
Show others and affiliations
2010 (English)In: Clinical Implant Dentistry and Related Research, ISSN 1523-0899, E-ISSN 1708-8208, Vol. 12, no 2, p. 81-90Article in journal (Refereed)
Abstract [en]

BACKGROUND: New computer numeric controlled (CNC)-milled frameworks for implant-supported prostheses have been introduced. However, no data are available on the precision of fit of these new frameworks. PURPOSE: The purpose of this study is to evaluate the precision of fit of a new CNC-milled framework technique (I-Bridge, Biomain AB, Helsingborg, Sweden) using Brånemark System (Nobel Biocare AB, Göteborg, Sweden) and NobelReplace (Nobel Biocare AB) system implants. MATERIALS AND METHODS: Ten test frameworks were fabricated for one master model for each implant system. Five additional frameworks were fabricated for five different models simulating clinical cases as controls (Brånemark System). The distortion of implant center point positions was measured in x-, y-, and z-axes and in three dimensions by using a contact-type coordinate measuring machine and a computer program developed specifically for this purpose. Mann-Whitney U-test was used to compare differences of distortion within and between the groups. RESULTS: The maximal distortion in arch width (x-axis) and curvature (y-axis) was within 71 and 55 microm for all frameworks, respectively. The mean distortion in absolute figures in x-, y-, z-axes and three dimensions was for "clinical control" frameworks 23, 26, 4, and 34 microm as compared with less than 12, 12, 2, and 17 microm for Brånemark and NobelReplace frameworks, respectively. Control frameworks showed significantly (p < .05) greater mean and range of distortions in x- and y-axes and in three dimensions compared with test frameworks. CONCLUSION: All measured frameworks presented signs of misfit, indicating that no framework had a "passive fit." Frameworks produced in a more routine clinical environment seem to present greater levels of distortion as compared with frameworks produced in a strict test situation. However, all measured frameworks presented levels of precision of fit within limits considered to be clinically acceptable in earlier studies of frameworks placed on abutments.

Place, publisher, year, edition, pages
2010. Vol. 12, no 2, p. 81-90
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-15900DOI: 10.1111/j.1708-8208.2008.00131.xISI: 000277321100001PubMedID: 19076180Scopus ID: 2-s2.0-77953745155Local ID: 11228OAI: oai:DiVA.org:mau-15900DiVA, id: diva2:1419422
Available from: 2020-03-30 Created: 2020-03-30 Last updated: 2024-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Wennerberg, Ann

Search in DiVA

By author/editor
Wennerberg, Ann
By organisation
Faculty of Odontology (OD)
In the same journal
Clinical Implant Dentistry and Related Research
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 21 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf