Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Micromorphological differences of the implant-abutment junction and in vitro load testing for three different titanium abutments on Straumann tissue level implants
Malmö högskola, Faculty of Odontology (OD).ORCID iD: 0000-0002-3912-0830
Show others and affiliations
2017 (English)In: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 28, no 12, p. 1523-1531Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: The aim of this study was to investigate the micromorphological differences among three commercially available titanium abutments on Straumann implants. Furthermore, the possible impact of functional loading on the micromorphology and potential complications was investigated with the use of in vitro testing. MATERIAL AND METHODS: Three groups of Titanium abutments (A: Straumann Variobase n = 5, B: EBI best Duo n = 5, and C: Implant Direct n = 5) were torqued on Straumann RN implants, as according to each of the manufacturer's instructions. The implant-abutment units were scanned with Micro-CT. Three units of each group were directly sliced in the microtome and photographed under different magnifications (10x-500x) through a Scanning Electron Microscope. Six units (two from each group) were restored with cement-retained crowns, subjected to 2000,000 load cycles with loads between 30 and 300 N at 2 Hz, examined through Micro-CT and finally sliced and photographed as described above. The micromorphology of each unit was studied, and the total length of tight contact (

Place, publisher, year, edition, pages
Blackwell Munksgaard, 2017. Vol. 28, no 12, p. 1523-1531
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-15678DOI: 10.1111/clr.13021ISI: 000416853000007PubMedID: 28397298Local ID: 23452OAI: oai:DiVA.org:mau-15678DiVA, id: diva2:1419200
Available from: 2020-03-30 Created: 2020-03-30 Last updated: 2022-06-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Mattheos, NikosLarsson, Christel

Search in DiVA

By author/editor
Mattheos, NikosLarsson, Christel
By organisation
Faculty of Odontology (OD)
In the same journal
Clinical Oral Implants Research
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 9 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf