Malmö University Publications
Planned maintenance
A system upgrade is planned for 10/12-2024, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Ex Vivo and In Vivo Biomechanical Test of Implant Attachment to Various Materials: Introduction of a New User-Friendly Removal Torque Equipment
Malmö högskola, Faculty of Odontology (OD).
2012 (English)In: Clinical Implant Dentistry and Related Research, ISSN 1523-0899, E-ISSN 1708-8208, Vol. 14, no 4, p. 603-611Article in journal (Refereed)
Abstract [en]

ABSTRACT Objective: The removal torque (RTQ) analysis is commonly used for biomechanical evaluation of osseointegration. The overall aim of this study was to verify results obtained with a newly developed equipment for biomechanical testing of osseointegration. Methods: Verification of the new equipment for biomechanical tests involved three experiments: Part I, comparison of RTQ between implants placed in four different types of dental synthetic plasters. Part II, comparison of RTQ between custom made, experimentally used implants to self-tapping, commercially available implants molded in the same type of dental plaster. Part III, comparison of RTQ between commercially pure titanium implants to Ti6Al4V implants placed in rabbit bone, 6 weeks after insertion. Briefly, for all experiments, the peak RTQ values and the removal process were recorded every 0.01 seconds up to 10 seconds. After the measurements, peak RTQ values were converted to shear strength. Results: The developed equipment sensitively responded to the changes of properties related to the molding plasters, implant topographies, and materials. The monitored graphs corresponded well to the expected properties of the different implants and tested materials. Conclusion: The new RTQ equipment proved to be accurate and could add new knowledge in understanding the biomechanical aspects of osseointegration.

Place, publisher, year, edition, pages
John Wiley & Sons, 2012. Vol. 14, no 4, p. 603-611
Keywords [en]
ex vivo, in vivo, removal torque, shear strength
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-15287DOI: 10.1111/j.1708-8208.2010.00296.xISI: 000307011400016PubMedID: 20662862Scopus ID: 2-s2.0-84864498020Local ID: 15651OAI: oai:DiVA.org:mau-15287DiVA, id: diva2:1418808
Available from: 2020-03-30 Created: 2020-03-30 Last updated: 2024-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Jimbo, Ryo

Search in DiVA

By author/editor
Jimbo, Ryo
By organisation
Faculty of Odontology (OD)
In the same journal
Clinical Implant Dentistry and Related Research
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 19 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf