Material degradation in implant-retained cobalt-chrome and titanium framworks
Malmö högskola, Faculty of Odontology (OD).
2011 (English)In: Journal of Oral Rehabilitation, E-ISSN 1365-2842, Vol. 38, no 1, p. 61-71Article in journal (Refereed)
Abstract [en]

The purpose of the study was to estimate in vitro material degradation in implants and cobalt-chrome or titanium frameworks, before and after exposure to artificial saliva. Four full-arch implant frameworks were fabricated according to the Cresco™ method (Astra Tech AB, Mölndal, Sweden), two in a cobalt-chrome alloy and two in commercially pure (CP) titanium. They were cut vertically, and the three central sections of each framework were used. Element leakage into an artificial saliva solution was observed with mass spectrometry. Before artificial saliva exposure, three Brånemark System(®) implants (Nobel Biocare AB, Gothenburg, Sweden) were screw-retained to cobalt-chrome sections, and three to titanium sections. The contact surfaces with the implants of the framework sections and the corresponding surfaces of six implants were examined with optical interferometry before and after exposure to artificial saliva to evaluate material degradation. Conventional descriptive statistics were used to present the mass spectrometry and interferometry data. One-way anova and Dunnett's T3 post hoc test were used to identify and study differences between the groups. To highlight changes within the groups, the Student's t-test was used. The significance level was set at 5%. There was significantly more leakage of cobalt elements than of titanium and chrome (P < 0·05). After saliva exposure and framework connection, the implants roughened (P < 0·05). The titanium frameworks were generally rougher than the cobalt-chrome frameworks, both before and after saliva exposure (P < 0·05). The findings in this study suggest active material degradation processes for both implants and framework materials.

Place, publisher, year, edition, pages
Blackwell Munksgaard, 2011. Vol. 38, no 1, p. 61-71
Keywords [en]
cobalt-chrome, titanium, implants, degradation, surface roughness
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-6955DOI: 10.1111/j.1365-2842.2010.02127.xISI: 000285249900010PubMedID: 20673295Scopus ID: 2-s2.0-78650063501Local ID: 12643OAI: oai:DiVA.org:mau-6955DiVA, id: diva2:1403909
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Wennerberg, A

Search in DiVA

By author/editor
Wennerberg, A
By organisation
Faculty of Odontology (OD)
In the same journal
Journal of Oral Rehabilitation
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 30 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf