A Novel Sensor for Bite Force Determinations
Malmö högskola, Faculty of Odontology (OD).
Malmö högskola, Faculty of Odontology (OD).
Malmö högskola, Faculty of Odontology (OD).
2003 (English)In: Dental Materials, ISSN 0109-5641, E-ISSN 1879-0097, Vol. 19, no 2, p. 118-126Article in journal (Other academic) Published
Abstract [en]

OBJECTIVES: The clinical usefulness, accuracy and precision of a novel bite force sensor based on force sensing resistors were tested in six subjects wearing maxillary removable partial dentures retained by conical crowns. METHODS: The surfaces of the sensor were manufactured in a silicone material that had mechanical properties similar to those of tough foodstuffs. In two separate series of standardized bite force tests, submaximum force levels were recorded with the sensor and with a strain gaged bite fork. Subjects were assisted in the loading tests with visual feedback instrumentation. Reliability estimates for the bite force sensor were calculated in order to show their reproducibility. Strain gages attached to the prostheses were used to determine the pattern of force distribution during loading tests. The bite force results obtained with the new bite force sensor and with the bite fork were analyzed with ANOVA and Scheffes tests. The strain patterns registered with strain gages were analyzed with F-test. RE-SULTS: The bite force sensor and the bite fork transducer showed no statistically significant differences in respect of intra-individual bite force levels (range 50-300N). The bite forces registered with the new sensor were dependent on the loading position (p<0.05), sex (p<0.05) and test subject (p<0.05). The reliability of the new sensor for sub-maximum bite forces was calculated to be 93%. Strain gage results showed that the new sensor generated strain patterns of less variance (p<0.05) than the bite fork and therefore allowed for higher precision during biting tests. SIGNIFICANCE: The presented instrument has such clinical merits, as to favor its use in experimental clinical studies on the biomechanics of prosthetic appliances.

Place, publisher, year, edition, pages
2003. Vol. 19, no 2, p. 118-126
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-6732DOI: 10.1016/S0109-5641(02)00020-9PubMedID: 12543117Scopus ID: 2-s2.0-0038654328Local ID: 3017OAI: oai:DiVA.org:mau-6732DiVA, id: diva2:1403682
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Glantz, Per Olof

Search in DiVA

By author/editor
Glantz, Per Olof
By organisation
Faculty of Odontology (OD)
In the same journal
Dental Materials
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 26 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf