Characteristics of implant-CAD/CAM abutment connections of two different internal connection systems
Malmö högskola, Faculty of Odontology (OD).
Show others and affiliations
2012 (English)In: Journal of Oral Rehabilitation, E-ISSN 1365-2842, Vol. 39, no 5, p. 391-398Article in journal (Refereed) Published
Abstract [en]

Titanium or zirconium computer-aided design/computer-aided manufacturing abutments are now widely used for aesthetic implant treatments; however, information regarding microscopic structural differences that may influence the biological and mechanical outcomes of different implant systems is limited. Therefore, the characteristics of different connection systems were investigated. Optical microscopic observation and scanning electron microscopy showed different characteristics of two internal systems, namely the Astra Tech and the Replace Select system, and for different materials. The scanning electron microscopic observation showed for the Astra Tech that the implant-abutment interface seemed to be completely sealed for both titanium and zirconium abutments, both horizontally and sagittally; however, the first implant-abutment contact was below the fixture top, creating a microgap, and fixtures connected with titanium abutments showed significantly larger values (23·56μm±5·44 in width, and 168·78μm±30·39 in depth, P<0·001). For Replace Select, scanning electron microscopy in the sagittal direction showed that the sealing of titanium and zirconium abutments differed. The seal between the implant-titanium and implant-zirconium abutments seemed to be complete at the butt-joint interface; however, the displacement of the abutment in relation to the fixture in the lateral direction was evident for both abutments with no statistical differences (P>0·70), creating an inverted microgap. Thus, microscopy evaluation of two commonly used internal systems connected to titanium or zirconium abutments showed that the implant-abutment interface was perfectly sealed under no-loading conditions. However, an inverted microgap was seen in both systems, which may result in bacterial accumulation as well as alteration of stress distribution at the implant-abutment interface.

Place, publisher, year, edition, pages
John Wiley & Sons, 2012. Vol. 39, no 5, p. 391-398
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-5993DOI: 10.1111/j.1365-2842.2011.02273.xISI: 000302614900010PubMedID: 22175784Scopus ID: 2-s2.0-84859609201Local ID: 14718OAI: oai:DiVA.org:mau-5993DiVA, id: diva2:1402881
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Braian, MichaelVandeweghe, StefanWennerberg, AnnJimbo, Ryo

Search in DiVA

By author/editor
Braian, MichaelVandeweghe, StefanWennerberg, AnnJimbo, Ryo
By organisation
Faculty of Odontology (OD)
In the same journal
Journal of Oral Rehabilitation
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 32 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf