Malmö University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Surface characterization of commercial oral implants on the nanometer level
Malmö högskola, Faculty of Odontology (OD).
2010 (English)In: Journal of Biomedical Materials Research. Part B - Applied biomaterials, ISSN 1552-4973, E-ISSN 1552-4981, Vol. 92B, no 2, p. 462-469Article in journal (Refereed) Published
Abstract [en]

Lately, there has been a growing interest in how the presence of nanometer structures on a bone integrated implant surface influences the healing process. Recent in vitro studies have revealed an increased osteoblast response to different nanophase surfaces. Some commercial implant brands claim their implants have nanometer structures. However, at present, there are no studies where the nano topography of today's commercially available oral implants has been investigated. The aim of this study was to characterize commercial oral implants on the nanometer level and to investigate whether or not the nanometer surface roughness was correlated to the more well-known micrometer roughness on the implants. Twelve different commercial screw-shaped oral implants with various surface modifications were examined using scanning electron microscopy and a white light interferometer. The interferometer is suitable for detection of nanoscale roughness in the vertical dimension; however, limitation exists on the horizontal due to the wavelength of the light. A 1 x 1 microm Gaussian filter was found to be useful for identifying nm roughness with respect to height deviation. The results demonstrated that an implant that was smooth on the micrometer level was not necessarily smooth on the nanometer level. Different structures in the nanometer scale was found on some of the implants, indicating that to fully understand the relationship between the properties of an implant surface and its osseointegration behavior, a characterization at the nanometer scale might be relevant.

Place, publisher, year, edition, pages
John Wiley & Sons, 2010. Vol. 92B, no 2, p. 462-469
Keywords [en]
dental/endosteal implant, nanotechnology, surface analysis, surface characterization
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-5966DOI: 10.1002/jbm.b.31538ISI: 000274266200021PubMedID: 19957360Scopus ID: 2-s2.0-74749086013Local ID: 9910OAI: oai:DiVA.org:mau-5966DiVA, id: diva2:1402853
Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-11-19Bibliographically approved
In thesis
1. On the importance of nanometer structures for implant incorporation in bone tissue
Open this publication in new window or tab >>On the importance of nanometer structures for implant incorporation in bone tissue
2011 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Introduction Replacing lost teeth with dental implants is today a reliable treatment method associated with good long-term clinical results. Different surface modifications alter the surface topography at micro- and nanometer level of resolution as well as chemical properties, which have shown to be of importance for osseointegration. Research within the field of implantology is still intense and aims at further improving the implant properties to achieve successful treatments for patients with compromised bone as well as developing a surface that provides faster integration to shorten the treatment period. Furthermore, more basic science data is needed to increase our understanding of the mechanisms involved in osseointegration. The significance of the surface topography on the micrometer level for implant integration is well known. However, the knowledge of how and to what extent nanostructures may be of importance in early bonehealing and osseointegration remains to be investigated. Aim The overall aim of this thesis was to describe a technique to characterize commercial oral implants on the nanometer level when nanostructures are applied on a microroughness and to investigate whether or not the nanometer surface roughness was correlated to the more well-known micrometer roughnesss; to study the real-time initial cellular interactions of human osteoblasts and fibroblasts to different implant surfaces with and without a coat of nanocrystalline hydroxyapatite; and to evaluate the early bone response to a nanocrystalline hydroxyapatite coating (nano-HA) applied on smooth cylindrical and moderately rough screw-shaped implants. Materials and Methods Twelve different commercial screw-shaped dental implants with different surface modifications were examined using optical interferometry together with Gaussian digital filters and scanning electron microscopy (SEM). Human osteoblasts and fibroblasts were used when investigating the initial cell-surface interaction to different surfaces modifications with optical tweezers (OT) and quartz crystal balance with dissipation monitoring (QCM-D). To evaluate the effect of nanocrystalline hydroxyapatite (nano-HA) compared to nanosized particles of titanium in early bone response, smooth cylindrical titanium implants with no microroughness were inserted in rabbit tibia. The implant surfaces were examined using atomic force microscopy (AFM) and interferometry. To evaluate the biological response, histological analyses including bone contact (BIC) and bone area (BA), as well as qualitative analysis were performed. Furthermore, screw-shaped sandblasted and acid etched titanium implants coated with nano-HA of different thicknesses and un-coated controls were evaluated in rabbit tibia as well as femur. Interferometry, SEM and X-ray Photoelectron Spectroscopy (XPS) were used to characterize the implant surface topography and chemical composition. Biomechanical and histological evaluations including BA, newly formed bone and qualitative evaluations were performed. Results The studies showed that it is possible to characterize the surface nanoroughness of commercially dental implants using interferometry. A 1x1μm Gaussian filter was found useful to identify nanoroughness in terms of height deviation. It was demonstrated that the implants do have distinct roughness on the nanometer level of resolution and that the nanoroughness is not correlated to the microroughness when comparing mean surface roughness (Sa). Significant differences in Sa on the nanometer scale were found among some of the implants investigated. However, to detect specific nanostructures an additional SEM examination is necessary. The results from optical trap experiments showed that both osteoblasts and fibroblasts responded in a similar way towards most of the surfaces. No difference in initial cell attachment could be detected between the surfaces when using the QCM-D technique. A nano-HA coating applied on smooth cylindrical implants did not enhance bone responses in terms of bone contact (BIC) and bone area (BA) values as compared to nano-titania. Screw-shaped sandblasted and acid etched titanium implants with applied nanothick (~20nm) coating of nano-HA with similar Sa values on both micro- and nanometer scale of resolution presented similar removal torque values, BA values and showed similar amounts of newly formed bone as compared to un-coated controls when placed in cortical bone. The same result was demonstrated in trabecular bone with a submicron thick coating of nano-HA onto sandblasted and acid etched screw-shaped implants. Conclusions Within the limits of the studies in this thesis, it was demonstrated that commercially available oral implants do have nanoroughness of various amounts and that the nanoroughness is not correlated to the microroughness. It was demonstrated possible to observe cell attachment using optical trapping and QCM-D, however no obvious differences between the surfaces could be detected. A nano-HA coating applied on cylindrical titanium implants did not enhance early bone response compared to a nano-titania coating when evaluated in cortical bone. Furthermore, sandblasted and acid etched screw-shaped implants with applied coatings of different thicknesses of nano-HA perform similar as un-coated controls when evaluated in cortical and trabecular bone.

Place, publisher, year, edition, pages
Department of Biomaterials Institute of Clinical Sciences The Sahlgrenska Academy at University of Gothenburg, 2011. p. 84
Series
Doctoral Dissertation in Odontology
National Category
Dentistry
Identifiers
urn:nbn:se:mau:diva-7718 (URN)11848 (Local ID)978-91-7104-384-9 (ISBN)11848 (Archive number)11848 (OAI)
Note

Note: The papers are not included in the fulltext online.

Paper V in dissertation as manuscript with title "“Evaluation of early bone healing on sandblasted and acid etched implants coated with nanocrystalline hydroxyapatite - An in vivo study in rabbit femur” "

Available from: 2020-02-28 Created: 2020-02-28 Last updated: 2024-03-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Wennerberg, Ann

Search in DiVA

By author/editor
Wennerberg, Ann
By organisation
Faculty of Odontology (OD)
In the same journal
Journal of Biomedical Materials Research. Part B - Applied biomaterials
Dentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 34 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf