Publikationer från Malmö universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect of electric potential and current on mandibular linear measurements in cone beam CT
Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Malmö högskola, Odontologiska fakulteten (OD).
2012 (Engelska)Ingår i: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, E-ISSN 1476-542X, Vol. 41, nr 7, s. 578-582Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives The purpose of this study was to compare mandibular linear distances measured from cone beam CT (CBCT) images produced by different radiographic parameter settings (peak kilovoltage and milliampere value). Methods 20 cadaver hemimandibles with edentulous ridges posterior to the mental foramen were embedded in clear resin blocks and scanned by a CBCT machine (CB MercuRayTM; Hitachi Medico Technology Corp., Chiba-ken, Japan). The radiographic parameters comprised four peak kilovoltage settings (60 kVp, 80 kVp, 100 kVp and 120 kVp) and two milliampere settings (10 mA and 15 mA). A 102.4 mm field of view was chosen. Each hemimandible was scanned 8 times with 8 different parameter combinations resulting in 160 CBCT data sets. On the cross-sectional images, six linear distances were measured. To assess the intraobserver variation, the 160 data sets were remeasured after 2 weeks. The measurement precision was calculated using Dahlberg's formula. With the same peak kilovoltage, the measurements yielded by different milliampere values were compared using the paired t-test. With the same milliampere value, the measurements yielded by different peak kilovoltage were compared using analysis of variance. A significant difference was considered when p < 0.05. Results Measurement precision varied from 0.03 mm to 0.28 mm. No significant differences in the distances were found among the different radiographic parameter combinations. Conclusions Based upon the specific machine in the present study, low peak kilovoltage and milliampere value might be used for linear measurements in the posterior mandible.

Ort, förlag, år, upplaga, sidor
British Institute of Radiology , 2012. Vol. 41, nr 7, s. 578-582
Nyckelord [en]
cone-beam computed tomography, dental implants, mandible
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:mau:diva-6123DOI: 10.1259/dmfr/51664704ISI: 000309636800008PubMedID: 22499132Scopus ID: 2-s2.0-84866619387Lokalt ID: 15653OAI: oai:DiVA.org:mau-6123DiVA, id: diva2:1403011
Tillgänglig från: 2020-02-28 Skapad: 2020-02-28 Senast uppdaterad: 2023-07-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Petersson, Arne

Sök vidare i DiVA

Av författaren/redaktören
Petersson, Arne
Av organisationen
Odontologiska fakulteten (OD)
I samma tidskrift
Dento-Maxillo-Facial Radiology
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 16 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf